Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 16(6): 681-689, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-36990558

RESUMEN

BACKGROUND: The self-expanding, intra-annular Navitor (Abbott Structural Heart) valve includes an outer cuff to reduce paravalvular leak (PVL) and large stent cells for future coronary access. OBJECTIVES: The purpose of the PORTICO NG (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis) study is to evaluate the safety and effectiveness of the Navitor valve in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicenter, global study with follow-up at 30 days, 1 year, and annually through 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 260 subjects were treated at 26 clinical sites across Europe, Australia, and the United States between September 2019 and August 2022. The mean age was 83.4 ± 5.4 years, 57.3% were female, and the average Society of Thoracic Surgeons score was 3.9% ± 2.1%. At 30 days, the rate of all-cause mortality was 1.9%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 1.9%, life-threatening bleeding was 3.8%, stage 3 acute kidney injury was 0.8%, major vascular complications were 4.2%, and new permanent pacemaker implantation was 19.0%. Hemodynamic performance included a mean gradient of 7.4 ± 3.5 mm Hg and an effective orifice area of 2.00 ± 0.47 cm2. CONCLUSIONS: The Navitor valve is safe and effective for the treatment of subjects with severe aortic stenosis who are at high or greater risk for surgery, which is supported by low rates of adverse events and PVL. (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis [PORTICO NG]; NCT04011722).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Estados Unidos , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Diseño de Prótesis
2.
EuroIntervention ; 19(3): 248-255, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-36895190

RESUMEN

BACKGROUND: The Navitor transcatheter heart valve (THV) is a self-expanding valve, with an intra-annular leaflet position and an outer cuff intended to reduce paravalvular leak (PVL). AIMS: The aim of the PORTICO NG Study is to assess the safety and performance of the Navitor THV in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicentre, global, single-arm, investigational study with follow-up at 30 days, 1 year, and annually up to 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 120 high- or extreme-risk subjects (age 83.5±5.4 years; 58.3% female; Society of Thoracic Surgeons score 4.0±2.0%) were enrolled in the European conformity (CE) mark cohort. Procedural success was high at 97.5%. At 30 days, the rate of all-cause mortality was 0%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 0.8%, life-threatening bleeding was 2.5%, stage 3 acute kidney injury 0%, major vascular complications 0.8%, and new pacemaker implantation 15.0%. At 1 year, the rates of all-cause mortality and disabling stroke were 4.2% and 0.8%, respectively. The rate of moderate PVL was 1.0% at 1 year. Haemodynamic performance with a mean gradient of 7.5±3.2 mmHg and effective orifice area of 1.9±0.4 cm2 was sustained up to 1 year. CONCLUSIONS: The PORTICO NG Study demonstrates low rates of adverse events and PVL up to 1 year in patients at high or extreme surgical risk, confirming the safety and efficacy of the Navitor THV system.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Diseño de Prótesis , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología
3.
J Clin Med ; 12(4)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36836219

RESUMEN

BACKGROUND: Readmissions within 1 year after percutaneous coronary intervention (PCI) are common (18.6-50.4% in international series) and a burden to patients and health services, however their long-term implications are not well characterised. We compared predictors of 30-day (early) and 31-day to 1-year (late) unplanned readmission and the impact of unplanned readmission on long-term clinical outcomes post-PCI. METHODS: Patients enrolled in the GenesisCare Cardiovascular Outcomes Registry (GCOR-PCI) from 2008 to 2020 were included in the study. Multivariate logistic regression analysis was performed to identify predictors of early and late unplanned readmission. A Cox proportion hazards regression model was used to explore the impact of any unplanned readmission during the first year post-PCI on the clinical outcomes at 3 years. Finally, patients with early and late unplanned readmission were compared to determine which group was at the highest risk of adverse long-term outcomes. RESULTS: The study comprised 16,911 consecutively enrolled patients who underwent PCI between 2009-2020. Of these, 1422 patients (8.5%) experienced unplanned readmission within 1-year post-PCI. Overall, the mean age was 68.9 ± 10.5 years, 76.4% were male and 45.9% presented with acute coronary syndromes. Predictors of unplanned readmission included increasing age, female gender, previous CABG, renal impairment and PCI for acute coronary syndromes. Unplanned readmission within 1 year of PCI was associated with an increased risk of MACE (adjusted HR 1.84 (1.42-2.37), p < 0.001) and death over a 3-year follow-up (adjusted HR 1.864 (1.34-2.59), p < 0.001) compared with those without readmission within 1-year post-PCI. Late compared with early unplanned readmission within the first year of PCI was more frequently associated with subsequent unplanned readmission, MACE and death between 1 and 3 years post-PCI. CONCLUSIONS: Unplanned readmissions in the first year following PCI, particularly those occurring more than 30 days after discharge, were associated with a significantly higher risk of adverse outcomes, such as MACE and death at 3 years. Strategies to identify patients at high risk of readmission and interventions to reduce their greater risk of adverse events should be implemented post-PCI.

4.
Heart Lung Circ ; 32(2): 224-231, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36344392

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established therapy for the treatment of aortic valve disease in appropriately selected patients. Previous studies using the self-expanding Portico transcatheter heart valve (THV), (Abbott Structural Heart, St Paul, MN, USA) have demonstrated the technical feasibility of this system albeit in the hands of relatively inexperienced Portico users. The objective of this study was to assess the real-world safety and efficacy of the Portico THV (with and without the FlexNav delivery system, Abbott Structural Heart) at the 30-day timepoint in an Australian cohort. METHODS AND RESULTS: This study was a retrospective real-world cohort analysis of 269 consecutive patients with severe aortic valve disease who underwent TAVI at multiple centres within Australia between February 2015 and April 2021. Of the 269 patients, 51.7% were female, mean Society of Thoracic Surgeons (STS) score was 5.2 (±6.8) and 98.5% had successful implantations. Thirty (30)-day post-implantation all-cause mortality was observed in one (0.4%) patient, major vascular complications in two (0.7%) patients, more-than-mild paravalvular leak in six (2.2%) patients and requirement for new permanent pacemaker implantation in 27 (10.2%) patients. Haemodynamic parameters at 30 days included mean effective orifice area (EOA) of 2.3 (±0.9) cm2 and mean aortic valve gradient (AVG) of 9.6 (±6.2) mmHg. CONCLUSION: This analysis of the Portico THV in a real-world setting suggested that the system is associated with satisfactory safety and efficacy parameters. Previously published datasets may not have found similar findings owing to lower operator experience with the Portico THV system.


Asunto(s)
Enfermedad de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Australia/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Enfermedad de la Válvula Aórtica/cirugía , Diseño de Prótesis
5.
JACC Cardiovasc Interv ; 15(11): 1153-1163, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35680195

RESUMEN

BACKGROUND: Resolute Onyx polymer-based zotarolimus-eluting stents (ZES) were noninferior in safety and effectiveness to BioFreedom polymer-free biolimus A9-coated stents (DCS) in high-bleeding-risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) at 1 year. OBJECTIVES: This study reports the final 2-year results of the randomized Onyx ONE trial. METHODS: The Onyx ONE (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy (DAPT) for High-Bleeding Risk Patients) trial randomly assigned HBR patients to treatment with ZES or DCS. Following 1-month DAPT, event-free patients received SAPT (either aspirin or a P2Y12 inhibitor at physician discretion). The primary safety endpoint, a composite of cardiac death, myocardial infarction, or stent thrombosis at 1 year, was determined at 1 year. Rates of primary and secondary endpoints were calculated after final follow-up at 2 years. RESULTS: A total of 1,003 patients were randomly allocated to ZES and 993 patients to DCS. Follow-up was complete in 980 (97.7%) ZES patients and 962 (96.9%) DCS patients at 2 years. The primary safety endpoint occurred in 208 (21.2%) patients in the ZES group and 199 (20.7%) patients in the DCS group (risk difference: 0.5%; 95% CI: -3.1% to 4.2%; P = 0.78) at 2 years without significant differences in individual components of the composite endpoint. The secondary effectiveness endpoint occurred in 217 (22.1%) patients in the ZES group and 202 (21.0%) patients in the DCS group (risk difference: 1.1%; 95% CI: -2.5% to 4.8%; P = 0.54). CONCLUSIONS: Among patients at HBR treated with 1-month DAPT followed by SAPT, the Resolute Onyx polymer-based ZES had similar 2-year outcomes for the primary safety and secondary effectiveness endpoint compared with the BioFreedom polymer-free DCS. (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy [DAPT] for High-Bleeding Risk Patients [Onyx ONE]; NCT03344653).


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Polímeros , Diseño de Prótesis , Stents/efectos adversos , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 99(3): 583-592, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34478233

RESUMEN

OBJECTIVES: To compare clinical outcomes in high bleeding risk (HBR) patients with and without complex percutaneous coronary intervention (PCI) treated with Resolute Onyx zotarolimus-eluting stents (ZES) after 1-month dual antiplatelet therapy (DAPT). BACKGROUND: PCI with 1-month DAPT has been demonstrated to be safe in HBR patients treated with Resolute Onyx ZES. Whether these outcomes are consistent in patients with complex lesions is uncertain. METHODS: Among HBR patients who were event-free 1 month after PCI with ZES and treated thereafter with single antiplatelet therapy (SAPT), the clinical outcomes between 1 month and 1 year were compared after complex PCI (3 vessels treated, ≥ 3 lesions treated, total stent length > 60 mm, bifurcation with ≥ 2 stents implanted, atherectomy, or left main, surgical bypass graft or chronic total occlusion PCI) versus noncomplex PCI. Propensity score adjustment was performed to adjust for baseline differences among complex and noncomplex patients. RESULTS: Complex patients (N = 401, 26.6% of total) had a higher prevalence of hyperlipidemia, diabetes mellitus and previous myocardial infarction (MI). Between 1 month and 1 year, rates of MI (7.1% vs. 4.0%, p = 0.02) and cardiac death/MI (9.3% vs. 6.1%, p = 0.04) were higher among complex versus noncomplex patients, although stent thrombosis rates were similar. After adjustment for baseline characteristics, differences in outcomes were no longer significant between groups. CONCLUSIONS: Higher rates of ischemic outcomes in complex PCI patients were largely explained by baseline clinical differences, rather than lesion complexity, among HBR patients treated with 1-month DAPT following PCI with Resolute Onyx ZES.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria , Resultado del Tratamiento
7.
J Clin Med ; 12(1)2022 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-36615080

RESUMEN

Introduction: Several large registries have evaluated outcomes after percutaneous coronary intervention (PCI) in the USA, however there are no contemporary data regarding long-term outcomes after PCI, particularly comparing new generation drug-eluting stents (DES) with other stents in Australia. Additionally, approval of new-generation drug-eluting stents (DES) is almost exclusively based on non-inferiority trials comparing outcomes with early generation DES, and there are limited data comparing safety and efficacy outcomes of new-generation DES with bare metal stents (BMS). This study reports in-hospital and long-term outcomes after PCI with the Xience DES from a large national registry, the GenesisCare Outcomes Registry (GCOR). Methods: The first 1500 patients consecutively enrolled from January 2015 to January 2019 and treated exclusively with either Xience DES or BMS and eligible for 1-year follow-up were included. Baseline patient and procedural data, major adverse cardiovascular events (MACE) in-hospital, at 30 days and 1-year, and medications were reported and analysed with respect to Xience DES (n = 1000) or BMS (n = 500) use. Results: In this cohort the mean age was 68.4 ± 10.7 years, 76.9% were male, 24.6% had diabetes mellitus and 45.9% presented with acute coronary syndromes. Of the overall cohort of 4765 patients from this period including all DES types, and patients who received multiple DES or a combination of DES and BMS, DES were exclusively used in 3621 (76.0%) patients, and BMS were exclusively used in 596 (12.5%). In comparison to international cohorts, adverse clinical event rates were low at 30 days in terms of mortality (0.20%), target lesion revascularisation (TLR, 0.27%) and MACE (0.47%), and at 12 months for mortality (1.26%) TLR (1.16%) and MACE (1.78%). Conclusions: Clinical practice and long-term outcomes of PCI with the Xience DES in Australia are consistent with international series. Recent trends indicate DES use has increased in parallel with good outcomes despite an increasingly complex patient and lesion cohort.

8.
Circ Cardiovasc Interv ; 13(11): e009565, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33167705

RESUMEN

BACKGROUND: Despite treatment guidance endorsing shortened dual antiplatelet therapy (DAPT) duration in high bleeding risk (HBR) patients after drug-eluting stents, limited evidence exists to support these recommendations. The present study was designed to examine the safety and effectiveness of 1-month DAPT duration following percutaneous coronary intervention with zotarolimus-eluting stents in HBR patients. METHODS: Onyx ONE Clear was a prospective, multicenter, nonrandomized study evaluating the safety and effectiveness of 1-month DAPT followed by single antiplatelet therapy in HBR patients undergoing percutaneous coronary intervention with Resolute Onyx drug-eluting stents. The primary analysis of cardiac death or myocardial infarction between 1 month and 1 year was performed in the prespecified one-month clear population of patients pooled from the Onyx ONE US/Japan study and Onyx ONE randomized controlled trial. One-month clear was defined as DAPT adherence and without major adverse events during the first month following percutaneous coronary intervention. RESULTS: Among patients enrolled in Onyx ONE US/Japan (n=752) and Onyx ONE randomized controlled trial (n=1018), 1506 patients fulfilled one-month clear criteria. Mean HBR characteristics per patient was 1.6 with 44.7% having multiple risks. By 2 months and 1 year, respectively, 96.9% and 89.3% of patients were taking single antiplatelet therapy. Between 1 month and 1 year, the rate of the primary end point was 7.0%. The 1-sided upper 97.5% CI was 8.4%, less than the performance goal of 9.7% (P<0.001). CONCLUSIONS: Among HBR patients who were event free before DAPT discontinuation at 1 month, favorable safety and effectiveness through 1 year support treatment with Resolute Onyx drug-eluting stents as part of an individualized strategy for shortened DAPT duration following percutaneous coronary intervention. Registration: URL: https://www.clinicaltrials.gov; Unique identifier NCT03647475.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Esquema de Medicación , Terapia Antiplaquetaria Doble/efectos adversos , Femenino , Hemorragia/inducido químicamente , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
9.
Int J Cardiol Heart Vasc ; 30: 100643, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33015315

RESUMEN

BACKGROUND: The present study is a prospective observational single arm clinical investigation, with parallel bench test interrogation, aimed at investigating the technical feasibility, safety and clinical outcomes with the cone flare crush modified-T (CFCT) bifurcation stenting technique. Bifurcation percutaneous coronary intervention (PCI) remains an area of ongoing procedural evolution. More widely applicable and reproducible techniques are required. METHODS: From April 2018 until March 2019, 20 consecutive patients underwent bifurcation PCI using the CFCT technique with a Pt-Cr everolimus drug-eluting stent with a bioresorbable polymer. Exercise stress echocardiography was performed at 12-month follow-up. The primary outcome was a composite of cardiac related mortality, myocardial infarction, target lesion/vessel revascularization and stroke. Safety secondary endpoints included bleeding, all-cause mortality and stent thrombosis. RESULTS: All patients underwent a successful CFCT bifurcation procedure with no complications to 30-day follow-up. One patient met the primary endpoint requiring target lesion revascularization at 9 months for stable angina. There were no other primary or secondary outcome events in the cohort. There were no strokes, deaths, stent thrombosis or myocardial infarction during the follow-up period. The mean CCS score improved from 2.25 to 0.25 (p < 0.0001). Optical coherence tomography (OCT) and bench test findings indicated optimal side branch ostial coverage and minimal redundant strut material crowding the neo-carina. CONCLUSIONS: The CFCT technique appears to be a safe, efficacious and feasible strategy for managing coronary artery bifurcation disease. Expanded and randomized datasets with longer term follow-up are required to further explore confirm this feasibility data. (ANZCTR ID: ACTRN12618001145291).

10.
N Engl J Med ; 382(13): 1208-1218, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32050061

RESUMEN

BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Polímeros , Sirolimus/análogos & derivados , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos/efectos adversos , Cardiopatías/mortalidad , Hemorragia/inducido químicamente , Humanos , Estimación de Kaplan-Meier , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Método Simple Ciego , Sirolimus/administración & dosificación
11.
Catheter Cardiovasc Interv ; 95(6): 1076-1084, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31489742

RESUMEN

OBJECTIVES: To evaluate the long-term safety and efficacy of the novel combined sirolimus-eluting endothelial progenitor cell capture Combo stent (OrbusNeich, Fort Lauderdale, FL) at 5 years in the REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coated bio-Engineered stEnt) trial. BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by late and very late thrombosis and accelerated neoatherosclerosis. Alternative or adjunctive technologies are needed to address these limitations. METHODS: A total of 183 patients with de novo lesions in native coronary arteries were randomized 2:1 to Combo (n = 124) or Taxus Liberté (n = 59). Primary endpoint was 9 month angiographic in-stent late lumen loss and the secondary endpoint was the occurrence of major adverse events (MACE) through 5-year follow-up. RESULTS: Compared with Taxus, after 5 years the Combo stent was associated with similar rates of MACE (18.3% vs. 16.9%, p = .89), cardiac death (0.8% vs. 5.1%, p = .07), myocardial infarction (4.1% vs. 3.4%, p = .81), target lesion (9.4% vs. 10.2%, p = .78), and target vessel revascularization (14.4% vs. 11.9%, p = .73). No cases of definite stent thrombosis were reported in the Combo group. The follow-up rate at 5 years was 97.7%. CONCLUSION: At 5-year follow-up, the Combo stent remained clinically safe and effective with an overall low rate of MACE comparable to Taxus.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Células Progenitoras Endoteliales/patología , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/patología , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
12.
Am J Physiol Heart Circ Physiol ; 317(4): H811-H819, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31441693

RESUMEN

A large body of evidence demonstrates an independent association between arterial stiffness and prospective risk of cardiovascular events. A reduction in coronary perfusion is presumed to underscore this association; however, studies confirming this are lacking. This study compared invasive measures of coronary blood flow (CBF) with cardiac magnetic resonance (CMR)-derived aortic distensibility (AD). Following coronary angiography, a Doppler FloWire and infusion microcatheter were advanced into the study vessel. Average peak velocity (APV) was acquired at baseline and following intracoronary adenosine to derive coronary flow velocity reserve (CFVR = hyperemic APV/resting APV) and CBF [π × (diameter)2 × APV × 0.125]. Following angiography, patients underwent CMR to evaluate distensibility at the ascending aorta (AA), proximal descending aorta (PDA) and distal descending aorta (DDA). Fifteen participants (53 ± 13 yr) with minor epicardial disease (maximum stenosis <30%) were enrolled. Resting CBF was 44.1 ± 11.9 mL/min, hyperemic CBF was 143.8 ± 37.4 mL/min, and CFVR was 3.15 ± 0.48. AD was 3.89 ± 1.72·10-3mmHg-1 at the AA, 4.08 ± 1.80·10-3mmHg-1 at the PDA, and 4.42 ± 1.67·10-3mmHg-1 at the DDA. All levels of distensibility correlated with resting CBF (R2 = 0.350-0.373, P < 0.05), hyperemic CBF (R2 = 0.453-0.464, P < 0.01), and CFVR (R2 = 0.442-0.511, P < 0.01). This study demonstrates that hyperemic and, to a lesser extent resting CBF, are significantly associated with measures of aortic stiffness in patients with only minor angiographic disease. These findings provide further in vivo support for the observed prognostic capacity of large artery function in cardiovascular event prediction.NEW & NOTEWORTHY Cardiac magnetic resonance-derived aortic distensibility is associated with invasive measures of coronary blood flow. Large artery function is more strongly correlated with hyperemic than resting blood flow. Increased stiffness may represent a potential target for novel antianginal medications.


Asunto(s)
Aorta/fisiopatología , Circulación Coronaria , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Hiperemia/fisiopatología , Rigidez Vascular , Adenosina/administración & dosificación , Adulto , Anciano , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Vasodilatadores/administración & dosificación
13.
Coron Artery Dis ; 30(7): 520-527, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30883431

RESUMEN

BACKGROUND: Cardiovascular disease is the leading cause of death in patients with chronic kidney disease. Studies investigating the disproportionate burden of cardiovascular disease have occurred predominantly in the peripheral vasculature, often used noninvasive imaging modalities, and infrequently recruited patients receiving dialysis. This study sought to evaluate invasive coronary dynamic vascular function in patients with end-stage renal failure (ESRF). PATIENTS AND METHODS: Patients referred for invasive coronary angiography prior to renal transplantation were invited to participate. Control patients were recruited in parallel. Baseline characteristics were obtained. Coronary diameter (via quantitative coronary angiography) and coronary blood flow (via Doppler Flowire) were measured; macrovascular endothelial-dependent and independent effects were evaluated in response to intracoronary acetylcholine infusion (10 and 10 mol/l) and intracoronary glyceryl trinitrate, respectively. Microvascular function was evaluated by response to adenosine and expressed as coronary flow velocity reserve. Mean values were compared. RESULTS: Thirty patients were evaluated: 15 patients with ESRF (mean age 52.1 ± 9, male 73%) and 15 control patients (mean age 53.3 ± 13, male 60%). Comorbidity profile, aside from ESRF, was well matched. Baseline coronary blood flow was similar between groups (101.6 ± 10.3 vs. 103.4 ± 9.1 ml/min, P = 0.71), as was endothelial-dependent response to acetylcholine (159.1 ± 16.9 vs. 171.1 ± 16.8 ml/min, P = 0.41). Endothelial-independent response to glyceryl trinitrate was no different between groups (14.3 ± 3.1 vs. 13.1 ± 2.3%, P = 0.73. A significantly reduced coronary flow velocity reserve was observed in the ESRF cohort compared to controls (2.34 ± 0.4 vs. 3.05 ± 0.3, P = 0.003). CONCLUSION: Patients with ESRF had preserved endothelial-dependent function however compared to controls, demonstrated significantly attenuated microvascular reserve. An impaired response to adenosine may not only represent a component of the pathophysiological milieu in patients with ESRF but may also provide a basis for the suboptimal diagnostic performance of vasodilatory stress in this population.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Vasos Coronarios/fisiopatología , Endotelio Vascular/fisiopatología , Fallo Renal Crónico/fisiopatología , Microcirculación , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Hiperemia/fisiopatología , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Masculino , Persona de Mediana Edad , Vasodilatadores/administración & dosificación
14.
Int J Nephrol Renovasc Dis ; 11: 259-266, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30310302

RESUMEN

AIM: Radiofrequency ablation of peri-arterial renal autonomic nerves has been studied as a potential therapeutic option for resistant hypertension. While recent clinical trials have reported its efficacy, there is paucity of data addressing the effects of the procedure on renal arteries, such as changes in vessel and lumen areas. Herein, the effect of atheroma burden on renal arteries after renal denervation was assessed using computed tomography (CT) imaging. MATERIALS AND METHODS: Serial renal artery CT imaging was conducted in 38 patients from the EnligHTN™ I study, a prospective, multicenter study evaluating the efficacy of the EnligHTN multi-electrode radiofrequency ablation catheter in resistant hypertensive subjects. Cross-sectional images of renal arteries at 1 mm intervals were acquired using commercially available software (3mensio Structural Heart version 5.1). Vessel and lumen areas were manually traced in each image. Vessel wall volume (VWV) and percent vessel wall volume (P-VWV) were calculated. The measurements within the ablation (first 30 mm segments) and the non-ablation (subsequent 30 mm segment after the first bifurcation of renal arteries) zones were compared. RESULTS: On serial evaluation, greater increase in P-VWV and VWV was observed in the ablation zone (change in P-VWV, 6.7%±5.1% vs 3.6%±2.8%, P=0.001; change in VWV, 106.3±87.4 vs 23.0±18.2 mm3, P=0.001). Receiver-operating characteristic analysis demonstrated baseline P-VWV in the ablation zone >37.1% as an optimal cutoff value to predict its substantial progression after the procedure (area under the curve=0.88, sensitivity 89.8%, specificity 79.1%). CONCLUSION: Change in vessel wall was greater within the segments receiving renal artery denervation. Baseline VWV predicted its substantial increase after the procedure. These observations suggest that atheroma burden within the renal arteries is a potential contributing factor to vascular changes after renal sympathetic denervation.

15.
Circ Cardiovasc Interv ; 11(8): e006367, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30354779

RESUMEN

BACKGROUND: Acute kidney injury (AKI) can be a major complication of transcatheter aortic valve replacement (TAVR). Atheroembolization of debris during catheter manipulation has been considered as a potential factor causing AKI. This study investigates the impact of aortic atheroma burden on AKI post-TAVR and evaluates the potential of preoperative multislice computed tomographic (MSCT) imaging for the assessment of AKI in these patients. METHODS AND RESULTS: Preoperative multislice computed tomographic images were analyzed in 278 patients with symptomatic severe aortic stenosis who underwent TAVR. AKI was defined as an absolute increase in serum creatinine ≥0.3 mg/dL. Aorta vessel and lumen areas in each 1-mm cross-sectional image were measured. Percent atheroma volume above (PAVabove renal arteries) and below (PAVbelow renal arteries) renal arteries were calculated by the following formula: PAV={Σ (vessel area-lumen area)/Σ(vessel area)}×100. AKI occurred in 92 patients (33.1%) after TAVR. AKI was associated with a greater PAV above (30.4±8.2 versus 21.3±5.8%; P=0.02) but not below (28.9±7.7 versus 25.8±6.1%; P=0.41) the renal arteries. Greater PAVabove renal arteries was associated directly with AKI severity ( P=0.008) and inversely with recovery in serum creatinine level from peak to discharge ( r=0.78; P=0.002). Multivariate analysis demonstrated that PAVabove renal arteries was a significant predictor of AKI ( P=0.02). Receiver-operating curve analysis identified PAVabove renal arteries >29.5% as an optimal threshold to predict AKI. CONCLUSIONS: Suprarenal aortic atheroma burden is associated with the occurrence, severity, and recovery of AKI after TAVR. This highlights the utility of preoperative assessment of aortic atherosclerosis on multislice computed tomography to identify patients at high-risk for AKI.


Asunto(s)
Lesión Renal Aguda/epidemiología , Enfermedades de la Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Aortografía/métodos , Aterosclerosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesión Renal Aguda/diagnóstico , Anciano de 80 o más Años , Enfermedades de la Aorta/epidemiología , Enfermedades de la Aorta/patología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Aterosclerosis/epidemiología , Aterosclerosis/patología , Femenino , Humanos , Masculino , Nueva Gales del Sur/epidemiología , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
17.
Med J Aust ; 209(3): 136-141, 2018 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-30071816

RESUMEN

Aortic stenosis is the most common valvular lesion requiring intervention and with an ageing population, its burden is likely to increase. Increasing comorbidity and a desire for less invasive treatment strategies has facilitated the expansion of percutaneous aortic valve therapies. Robust clinical trial data are now available to support the role of transcatheter aortic valve implantation (TAVI) in patients of prohibitive, high and now intermediate surgical risk. The introduction of a Medicare Benefits Schedule reimbursement is likely to see TAVI use grow exponentially in Australia over the next 5 years. Clinical trials evaluating low risk patients may be the final frontier to see TAVI become the standard of care for most patients with severe aortic stenosis.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias , Factores de Riesgo , Nivel de Atención
18.
JAMA Cardiol ; 3(9): 815-822, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30046828

RESUMEN

Importance: CER-001 is a negatively charged, engineered pre-ß high-density lipoprotein (HDL) mimetic containing apolipoprotein A-I and sphingomyelin. Preliminary studies demonstrated favorable effects of CER-001 on cholesterol efflux and vascular inflammation. A post hoc reanalysis of a previously completed study of intravenous infusion of CER-001, 3 mg/k, showed that the intravenous infusion in patients with a high coronary plaque burden promoted regression as assessed by intravascular ultrasonography. Objective: To determine the effect of infusing CER-001 on coronary atherosclerosis progression in statin-treated patients. Design, Setting, and Participants: A double-blind, randomized, multicenter trial evaluating the effect of 10 weekly intravenous infusions of CER-001, 3 mg/kg, (n = 135) or placebo (n = 137) in patients with an acute coronary syndrome (ACS) and baseline percent atheroma volume (PAV) greater than 30% in the proximal segment of an epicardial artery by intravascular ultrasonography. The study included 34 academic and community hospitals in Australia, Hungary, the Netherlands, and the United States in patients with ACS presenting for coronary angiography. Patients were enrolled from August 15, 2015, to November 19, 2016. Interventions: Participants were randomized to receive weekly CER-001, 3 mg/kg, or placebo for 10 weeks in addition to statins. Main Outcomes and Measures: The primary efficacy measure was the nominal change in PAV from baseline to day 78 measured by serial intravascular ultrasonography imaging. The secondary efficacy measures were nominal change in normalized total atheroma volume and percentage of patients demonstrating plaque regression. Safety and tolerability were also evaluated. Results: Among 293 patients (mean [SD] age, 59.8 [9.4] years; 217 men [79.8%] and 261 white race/ethnicity [96.0%]), 86 (29%) had statin prior use prior to the index ACS and 272 (92.8%) had evaluable imaging at follow-up. The placebo and CER-001 groups had similar posttreatment median levels of low-density lipoprotein cholesterol (74 mg/dL vs 79 mg/dL; P = .15) and high-density lipoprotein cholesterol (43 mg/dL vs 44 mg/dL; P = .66). The primary efficacy measure, PAV, decreased 0.41% with placebo (P = .005 compared with baseline), but not with CER-001 (-0.09%; P = .67 compared with baseline; between group differences, 0.32%; P = .15). Similar percentages of patients in the placebo and CER-001 groups demonstrated regression of PAV (57.7% vs 53.3%; P = .49). Infusions were well tolerated, with no differences in clinical and laboratory adverse events observed between treatment groups. Conclusions and Relevance: Infusion of CER-001 did not promote regression of coronary atherosclerosis in statin-treated patients with ACS and high plaque burden. Trial Registration: ClinicalTrials.gov Identifier: NCT2484378.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/tratamiento farmacológico , Apolipoproteína A-I/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Fosfolípidos/administración & dosificación , Proteínas Recombinantes/administración & dosificación , Anciano , Apolipoproteína A-I/uso terapéutico , Australia , Progresión de la Enfermedad , Método Doble Ciego , Esquema de Medicación , Femenino , Humanos , Hungría , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Bombas de Infusión , Masculino , Persona de Mediana Edad , Países Bajos , Fosfolípidos/uso terapéutico , Proteínas Recombinantes/uso terapéutico , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos
19.
Atherosclerosis ; 272: 207-215, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29627741

RESUMEN

BACKGROUND AND AIMS: Echocardiographic studies have shown improvements in cardiac indices associated with renal sympathetic denervation (RDN), however, the benefits on myocardial perfusion have never been assessed. This trial was designed to study the effects of RDN on myocardial perfusion using cardiac magnetic resonance (CMR) imaging. METHODS: A total of 14 patients with resistant hypertension were recruited for RDN and myocardial perfusion, alongside other CMR indices, was assessed at baseline and at 6 months. RESULTS: RDN showed significant reduction of mean office blood pressures from 181/100 ±â€¯19/16 mmHg to 147/85 ±â€¯19/17 mmHg, 6 months after the procedure (p < 0.0001). This was combined with significant improvement in regional aortic distensibility (p < 0.02) and associated with trends of improved myocardial perfusion reserve index (baseline = 2.2 ±â€¯1; 6 months = 2.9 ±â€¯1 units) (p = 0.08). Left ventricular end systolic volume index decreased from baseline to 6 months post procedure, 27 ±â€¯13 ml/m2vs. 22 ±â€¯10 ml/m2 (p = 0.03), but there was no significant change in left ventricular end diastolic volume index (p = 0.09). There was significant improvement in mean left ventricular ejection fraction from 68 ± 10% to 72 + 9%, 6 months post procedure (p = 0.04). T1 mapping failed to detect fibrosis in these patients at baseline and therefore no change was noted, however, extracellular volume percent improved from 46 ±â€¯4% at baseline to 41 ±â€¯8% at 6 months (p = 0.002). CONCLUSIONS: This study demonstrates that renal sympathetic denervation increased myocardial perfusion by 32% as assessed by CMR, and, this was associated with improvements in cardiac volumes and function. Larger well controlled and randomized studies are required to assess the clinical significance of these findings.


Asunto(s)
Corazón/diagnóstico por imagen , Corazón/fisiología , Riñón/inervación , Miocardio/patología , Simpatectomía , Aorta/patología , Presión Sanguínea , Ecocardiografía , Humanos , Hipertensión/fisiopatología , Riñón/fisiopatología , Imagen por Resonancia Magnética , Perfusión , Estudios Prospectivos , Función Ventricular Izquierda
20.
Heart ; 104(17): 1439-1446, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29496901

RESUMEN

OBJECTIVE: Coronary vasodilator function and atherosclerotic plaque progression have both been shown to be associated with adverse cardiovascular events. However, the relationship between these factors and the lipid burden of coronary plaque remains unknown. These experiments focus on investigating the relationship between impaired coronary vasodilator function (endothelium dependent (salbutamol) and endothelium independent (glyceryl trinitrate)) and the natural history of atheroma plaque progression and lipid burden using dual modality intravascular ultrasound (IVUS) and near-infrared spectroscopy (NIRS) imaging. METHODS: 33 patients with stable chest pain or acute coronary syndrome underwent serial assessment of coronary vasodilator function and intracoronary plaque IVUS and NIRS imaging. Coronary segmental macrovascular response (% change segmental lumen volume (ΔSLV)), plaque burden (per cent atheroma volume (PAV)), lipid core (lipid-rich plaque (LRP) and lipid core burden index (LCBI)) were measured at baseline and after an interval of 12-18 months (n=520 segments). RESULTS: Lipid-negative coronary segments which develop into LRP over the study time period demonstrated impaired endothelial-dependent function (-0.24±2.96 vs 5.60±1.47%, P=0.04) and endothelial-independent function (13.91±4.45 vs 21.19±3.19%, P=0.036), at baseline. By multivariate analysis, endothelial-dependent function predicted ∆LCBI (ß coefficient: -3.03, 95% CI (-5.81 to -0.25), P=0.033) whereas endothelial-independent function predicted ∆PAV (ß coefficient: 0.07, 95% CI (0.04 to 0.10), P<0.0001). CONCLUSIONS: Epicardial coronary vasodilator function is a determinant of future atheroma progression and composition irrespective of the nature of clinical presentation. TRIAL REGISTRATION NUMBER: ACTRN12612000594820, Post-results.


Asunto(s)
Albuterol/farmacología , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Endotelio Vascular , Nitroglicerina/farmacología , Placa Aterosclerótica , Vasodilatación , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/fisiopatología , Progresión de la Enfermedad , Endotelio Vascular/efectos de los fármacos , Endotelio Vascular/fisiopatología , Femenino , Humanos , Lípidos/análisis , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/metabolismo , Valor Predictivo de las Pruebas , Espectroscopía Infrarroja Corta/métodos , Ultrasonografía Intervencional/métodos , Vasodilatación/efectos de los fármacos , Vasodilatación/fisiología , Vasodilatadores/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA