RESUMEN
Plakortone B is a naturally occurring bicyclic[3.3.0]furanolactone compound with attractive bioactivities. Although the relative configuration of plakortone B's central core had been established by NMR spectroscopic methods, the absolute configuration of its four stereocenters remained unknown. In the present paper, all four possible isomers of plakortone B were synthesized and one of these molecules was found to be identical with the natural plakortone B on the basis of (1)H, (13)C NMR spectra and specific rotation comparisons. Thus, the absolute configuration of the natural plakortone B was determined to be (3S,4S,6R,10R).
Asunto(s)
Lactonas/síntesis química , Catálisis , Ciclización , Lactonas/química , Espectroscopía de Resonancia Magnética/métodos , Estructura Molecular , EstereoisomerismoRESUMEN
OBJECTIVE: To estimate the biological exposure limit (BEL) using benchmark dose (BMD) based on two sets of data from occupational epidemiology. METHODS: Cadmium-exposed workers were selected from a cadmium smelting factory and a zinc product factory. Doctors, nurses or shop assistants living in the same area served as a control group. Urinary cadmium (UCd) was used as an exposure biomarker and urinary beta2-microgloburin (B2M), N-acetyl-13-D-glucosaminidase (NAG) and albumin (ALB) as effect biomarkers. All urine parameters were adjusted by urinary creatinine. Software of BMDS (Version 1.3.2, EPA.U.S.A) was used to calculate BMD. RESULTS: The cut-off point (abnormal values) was determined based on the upper limit of 95% of effect biomarkers in control group. There was a significant dose response relationship between the effect biomarkers (urinary B2M, NAG; and ALB) and exposure biomarker (UCd). BEL value was 5 microg/g creatinine for UB2M as an effect biomarker, consistent with the recommendation of WHO. BEL could be estimated by using the method of BMD. BEL value was 3 microg/g creatinine for UNAG as an effect biomarker. The more sensitive the used biomarker is, the more occupational population will be protected. CONCLUSION: BMD can be used in estimating the biological exposure limit (BEL). UNAG is a sensitive biomarker for estimating BEL after cadmium exposure.
Asunto(s)
Acetilglucosaminidasa/orina , Cadmio/toxicidad , Albuminuria/orina , Biomarcadores/orina , Cadmio/orina , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Exposición Profesional , Espectrofotometría Atómica , Microglobulina beta-2/orinaRESUMEN
OBJECTIVE: Based on two sets of data from occupational epidemiology, Benchmark dose (BMD) was applied to estimate biological exposure limit (BEL). METHODS: Cadmium exposed workers were selected from a cadmium smelting and a zinc products factory and control group was selected from doctors or nurses and staff from shops living in the same area; Urinary cadmium (UCd) was used as exposure biomarker and urinary beta(2) microglobulin (UBM), NAG (UNAG) and albumin (UALB) were as effect biomarkers. All urine parameters were adjusted by urinary creatinine. Software of BMDS (Version 1.3.2, EPA.U.S) was used to calculate BMD. RESULTS: Calculated abnormal prevalence was based on the upper limit of 95% of effect biomarkers in control group; There are significant dose response relationship between the prevalence of effect biomarkers (UBM, UNAG and UALB) and exposure biomarker (UCd); BEL was 5 microg/g creatinine for UBM as effect biomarker, It consists with the recommendation of WHO; BEL was 3 microg/g creatinine for UNAG as effect biomarker; BEL can be estimated by using the method of BMD; the more sensitive biomarker would used, the more occupational people would protected. CONCLUSION: The application of BMD in estimating biological exposure limit (BEL) is proper. UNAG is suggested as most sensitive biomarker to be used to estimate BEL for cadmium exposure.