Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Radiat Oncol ; 12(1): 32, 2017 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-28143487

RESUMEN

PURPOSE: To evaluate the efficacy and toxicity of helical tomotherapy (HT) in the management of spine chordomas when proton therapy is unavailable or non-feasible. METHODS AND MATERIALS: Between 2007 and 2013, 30 patients with biopsy-proven chordomas were treated by HT in five French institutions. Information regarding local control (LC), overall survival (OS), progression-free survival (PFS) and metastasis-free survival (MFS) was collected. Clinical efficacy, toxicity and treatment quality were evaluated. RESULTS: Two-year actuarial LC, OS, PFS and MFS were 69.9%, 96.7%, 61.2% and 76.4%, respectively. HT treatments were well tolerated and no Grade 4-5 toxicities were observed. HT permitted the delivery of a mean dose of 68 Gy while respecting organ at risk (OAR) dose constraints, in particular in the spinal cord and cauda equina. CONCLUSIONS: This multicentric, retrospective study demonstrated the feasibility of HT in the treatment of spine chordomas, in the absence of hadron therapy.


Asunto(s)
Cordoma/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Columna Vertebral/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Cordoma/patología , Femenino , Estudios de Seguimiento , Francia , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Pronóstico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Neoplasias de la Columna Vertebral/patología , Tasa de Supervivencia
2.
Radiother Oncol ; 91(3): 405-14, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19297051

RESUMEN

PURPOSE: To evaluate against Monte-Carlo the performance of various dose calculations algorithms regarding lung tumour coverage in stereotactic body radiotherapy (SBRT) conditions. MATERIALS AND METHODS: Dose distributions in virtual lung phantoms have been calculated using four commercial Treatment Planning System (TPS) algorithms and one Monte Carlo (MC) system (EGSnrc). We compared the performance of the algorithms in calculating the target dose for different degrees of lung inflation. The phantoms had a cubic 'body' and 'lung' and a central 2-cm diameter spherical 'tumour' (the body and tumour have unit density). The lung tissue was assigned five densities (rho(lung)): 0.01, 0.1, 0.2, 0.4 and 1g/cm(3). Four-field treatment plans were calculated with 6- and 18 MV narrow beams for each value of rho(lung). We considered the Pencil Beam Convolution (PBC(Ecl)) and the Analytical Anisotropic Algorithm (AAA(Ecl)) from Varian Eclipse and the Pencil Beam Convolution (PBC(OMP)) and the Collapsed Cone Convolution (CCC(OMP)) algorithms from Oncentra MasterPlan. RESULTS: When changing rho(lung) from 0.4 to 0.1g/cm(3), the MC median target dose decreased from 89.2% to 74.9% for 6 MV and from 83.3% to 61.6% for 18 MV (of dose maximum in the homogenous case at both energies), while for both PB algorithms the median target dose was virtually independent of lung density. CONCLUSIONS: Both PB algorithms overestimated the target dose, the overestimation increasing as rho(lung) decreased. Concerning target dose, the AAA(Ecl) and CCC(OMP) algorithms appear to be adequate alternatives to MC.


Asunto(s)
Algoritmos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Dosificación Radioterapéutica , Anisotropía , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Humanos , Pulmón/patología , Método de Montecarlo , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA