Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38488985

RESUMEN

OBJECTIVE: This study aims to investigate the clinical manifestations, operative techniques, and outcomes of patients who undergo open repair after thoracic endovascular aortic repair (TEVAR). METHODS: From January 2010 to June 2022, 113 consecutive type A aortic dissection (TAAD) patients underwent secondary open operation after TEVAR at our institution, and the median interval from primary intervention to open surgery was 12 (1.9-48.0) months. We divided the patients into two groups (RTAD (retrograde type A dissection) group, N = 56; PNAD (proximal new aortic dissection) group, N = 57) according to their anatomical features. Survival analysis during the follow-up was evaluated using a Kaplan-Meier survival curve and a log-rank test. RESULTS: The 30-day mortality was 6.2% (7/113), the median follow-up period was 31.7 (IQR 14.7-65.6) months, and the overall survival at 1 year, 5 years, and 10 years was 88.5%, 88.5%, and 87.6%, respectively. Fourteen deaths occurred during the follow-up, but there were no late aorta-related deaths. Three patients underwent total thoracoabdominal aortic replacement 1 year after a second open operation. The RTAD group had a smaller ascending aorta size (42.5 ± 7.7 mm vs 48.4 ± 11.4 mm; P < .01) and a closer proximal landing zone (P < .01) compared to the PNAD group. However, there were no differences in survival between the two groups. CONCLUSIONS: TAAD can present as an early or a late complication after TEVAR due to stent-grafting-related issues or disease progression. Open operation can be performed to treat TAAD, and this has acceptable early and mid-term outcomes. Follow-up should become mandatory for patients after TEVAR because these patients are at increased risk for TAAD.

2.
Quant Imaging Med Surg ; 14(2): 1477-1492, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38415169

RESUMEN

Background: It has been suggested that biomechanical factors may influence plaque development. However, key determinants for assessing plaque vulnerability remain speculative. Methods: In this study, a two-dimensional (2D) structural mechanical analysis and a three-dimensional (3D) fluid-structure interaction (FSI) analysis were conducted based on intravascular optical coherence tomography (IV-OCT) and digital subtraction angiography (DSA) data sets. In the 2D study, 103 IV-OCT slices were analyzed. An in-depth morpho-mechanic analysis and a weighted least absolute shrinkage and selection operator (LASSO) regression analysis were conducted to identify the crucial features related to plaque vulnerability via the tuning parameter (λ). In the 3D study, the coronary model was reconstructed by fusing the IV-OCT and DSA data, and a FSI analysis was subsequently performed. The relationship between vulnerable plaque and wall shear stress (WSS) was investigated. Results: The influential factors were selected using the minimum criteria (λ-min) and one-standard error criteria (λ-1se). In addition to the common vulnerable factor of the minimum fibrous cap thickness (FCTmin), four biomechanical factors were selected by λ-min, including the average/maximal displacements and average/maximal stress, and two biomechanical factors were selected by λ-1se, including the average/maximal displacements. Additionally, the positions of the vulnerable plaques were consistent with the sites of high WSS. Conclusions: Functional indices are crucial for plaque status assessment. An evaluation based on biomechanical simulations might provide insights into risk identification and guide therapeutic decisions.

3.
Small ; 20(3): e2305406, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37702139

RESUMEN

In recent years, nitrogen-doped carbons show great application potentials in the fields of electrochemical energy storage and conversion. Here, the ultrafast and green preparation of nitrogen-doped carbon nanotubes (N-CNTs) via an efficient flash Joule heating method is reported. The precursor of 1D core-shell structure of CNT@polyaniline is first synthesized using an in situ polymerization method and then rapidly conversed into N-CNTs at ≈1300 K within 1 s. Electrochemical tests reveal the desirable capacitive property and oxygen catalytic activity of the optimized N-CNT material. It delivers an improved area capacitance of 101.7 mF cm-2 at 5 mV s-1 in 1 m KOH electrolyte, and the assembled symmetrical supercapacitor shows an energy density of 1.03 µWh cm-2 and excellent cycle stability over 10 000 cycles. In addition, the flash N-CNTs exhibit impressive catalytic performance toward oxygen reduction reaction with a half-wave potential of 0.8 V in alkaline medium, comparable to the sample prepared by the conventional long-time pyrolysis method. The Zn-air battery presents superior charge-discharge ability and long-term durability relative to commercial Pt/C catalyst. These remarkable electrochemical performances validate the superiorities of the Joule heating method in preparing the heteroatom-doped carbon materials for wide applications.

4.
Angew Chem Int Ed Engl ; 62(42): e202309545, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37650786

RESUMEN

Iron phthalocyanine (FePc) with unique FeN4 site has attracted increasing interests as a promising non-precious catalyst. However, the plane symmetric structure endows FePc with undesired catalytic performance toward the oxygen reduction reaction (ORR). Here, we report a novel one-dimensional heterostructured ORR catalyst by coupling FePc at polyoxometalate-encapsulated carbon nanotubes (FePc-{PW12 }@NTs) using host-guest chemistry. The encapsulation of polyoxometalates can induce a local tensile strain of single-walled NTs to strengthen the interactions with FePc. Both the strain and curvature effects of {PW12 }@NT scaffold tune the geometric structure and electronic localization of FeN4 centers to enhance the ORR catalytic performance. As expected, such a heterostructured FePc-{PW12 }@NT electrocatalyst exhibits prominent durability, methanol tolerance, and ORR activity with a high half-wave potential of 0.90 V and a low Tafel slope of 30.9 mV dec-1 in alkaline medium. Besides, the assembled zinc-air battery demonstrates an ultrahigh power density of 280 mW cm-2 , excellent charge/discharge ability and long-term stability over 500 h, outperforming that of the commercial Pt/C+IrO2 cathode. This study offers a new strategy to design novel heterostructured catalysts and opens a new avenue to regulate the electrocatalytic performance of phthalocyanine molecules.

5.
Eur Radiol ; 33(12): 8682-8692, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37368110

RESUMEN

OBJECTIVES: The distal stent-induced new entry (distal SINE) is a life-threatening device-related complication after thoracic endovascular aortic repair (TEVAR). However, risk factors for distal SINE are not fully determined, and prediction models are lacking. This study aimed to establish a predictive model for distal SINE based on the preoperative dataset. METHODS: Two hundred and six patients with Stanford type B aortic dissection (TBAD) that experienced TEVAR were involved in this study. Among them, thirty patients developed distal SINE. Pre-TEVAR morphological parameters were measured based on the CT-reconstructed configurations. Virtual post-TEVAR morphological and mechanical parameters were computed via the virtual stenting algorithm (VSA). Two predictive models (PM-1 and PM-2) were developed and presented as nomograms to help risk evaluation of distal SINE. The performance of the proposed predictive models was evaluated and internal validation was conducted. RESULTS: Machine-selected variables for PM-1 included key pre-TEVAR parameters, and those for PM-2 included key virtual post-TEVAR parameters. Both models showed good calibration in both development and validation subsamples, while PM-2 outperformed PM-1. The discrimination of PM-2 was better than PM-1 in the development subsample, with an optimism-corrected area under the curve (AUC) of 0.95 and 0.77, respectively. Application of PM-2 in the validation subsample presented good discrimination with an AUC of 0.9727. The decision curve demonstrated that PM-2 was clinically useful. CONCLUSION: This study proposed a predictive model for distal SINE incorporating the CT-based VSA. This predictive model could efficiently predict the risk of distal SINE and thus might contribute to personalized intervention planning. CLINICAL RELEVANCE STATEMENT: This study established a predictive model to evaluate the risk of distal SINE based on the pre-stenting CT dataset and planned device information. With an accurate VSA tool, the predictive model could help to improve the safety of the endovascular repair procedure. KEY POINTS: • Clinically useful prediction models for distal stent-induced new entry are still lacking, and the safety of the stent implantation is hard to guarantee. • Our proposed predictive tool based on a virtual stenting algorithm supports different stenting planning rehearsals and real-time risk evaluation, guiding clinicians to optimize the presurgical plan when necessary. • The established prediction model provides accurate risk evaluation for vessel damage, improving the safety of the intervention procedure.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Incidencia , Stents/efectos adversos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Factores de Riesgo , Tomografía Computarizada por Rayos X/efectos adversos , Estudios Retrospectivos , Prótesis Vascular/efectos adversos
6.
J Endovasc Ther ; 30(3): 441-448, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35249398

RESUMEN

BACKGROUND: In this study, we aimed to evaluate hemodynamic influence of the dissected aortic system via various ex vivo type B aortic dissection (AD) models. METHODS: Twenty-four raw porcine aortas were harvested and randomly divided into 4 groups to create various aortic models. Model A was the control group, while models B to D indicated the AD group, where models B and C presented a proximal primary entry with the false lumen (FL) lengths of 15 and 20 cm, respectively, and model D presented a 20 cm FL with a proximal primary entry and a distal reentry. All the aortic models were connected to a mock circulation loop to attain the realistic flow and pressure status. The flow distribution rate (FDR) of the aortic branches was calculated. Doppler ultrasound was applied to visualize the AD structure and to attain the velocity of flow in both the true and false lumens. Several sections of the AD were stained with hematoxylin and eosin for histologic evaluation after the experiment. RESULTS: This study demonstrated that higher pressures were found for the AD group compared with the control group. The mean systolic pressures at the inlet of models A to D were 113.34±0.81, 120.58±0.52, 117.76±0.82, and 115.87±0.42 mm Hg, respectively. The FDRs of the celiac artery in models A to D were 8.65%, 8.32%±0.15%, 7.87%±0.13%, and 8.03%±0.21%, respectively. By ultrasound visualization, the velocity of the flow at the entry to the FL in the AD group ranged in 10 to 92 cm/s. The dissection flap presented pulsatile movement, especially in the models B and C which contained 1 primary entry without distal reentries. Histological examinations indicated that AD was located between the intimal and medial layers. CONCLUSIONS: Our ex vivo models demonstrated that the configuration of the dissected aorta influenced the pressure distribution. Moreover, the dissection flap affected the FDR of the aortic branches that possibly inducing malperfusion syndrome.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Disección Aórtica , Animales , Aorta/cirugía , Aneurisma de la Aorta/patología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/patología , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Hemodinámica , Porcinos , Resultado del Tratamiento
7.
Front Cardiovasc Med ; 9: 869505, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35586645

RESUMEN

Background: Endovascular repair of type B aortic dissection (TBAD) with aberrant right subclavian artery (ARSA) is challenging due to anatomical complexity. The embedded modular single-branched stent graft (EMSBSG) could solve this problem. However, the hemodynamic efficacy of this innovative technique has not been fully assessed. This study aimed to propose morphometric and functional indicators to quantify the outcomes of EMSBSG in treating TBAD with ARSA. Material and Methods: A patient who had TBAD with ARSA underwent EMSBSG implantation was admitted. Computational fluid dynamics (CFD) and three-dimensional structural analyses were conducted based on CTA datasets before the operation (Pre-1) and at 4 and 25 days after EMSBSG implantation (Post-1 and Post-2). Quantitative and qualitative functional analyses were conducted via pressure-, velocity- and wall shear stress (WSS) -based parameters, such as the luminal pressure difference (LPD), total energy loss, and flow distribution ratio. By precisely registering the aortas at the three time points, parameter variations in the EMSBSG region were also computed to investigate the prognostic improvement after EMSBSG implantation. Results: The first balance point of LPD distally shifted to the abdominal aorta in Post-1 by a distance of 20.172 cm, and shifted out of the dissected region in Post-2, indicating positive pressure recovery post EMSBSG. The flow distribution ratios of all aortic arch branches increased after EMSBSG implantation. A positive normal deformation index in the EMSBSG region confirmed true lumen expansion; dominant ARN (area ratio of negative value) of pressure and WSS-based parameters indicated an improved prognosis from Post-1 to Post-2. Conclusions: The short-term results of EMSBSG in treating TBAD with ARSA proved to be promising, especially in EMSBSG region. Comprehensive evaluation could provide new insight into the therapy of TBAD with ARSA. Thus, it might guide the further management of complex aortic arch lesions.

8.
Front Cardiovasc Med ; 9: 828910, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35449876

RESUMEN

Background: Iliac branch devices (IBDs) are valid tools for internal iliac artery preservation during endovascular abdominal aortic aneurysm and iliac aneurysm repair. The purpose of this study was to evaluate the effectiveness of a novel IBD with an embedded branch configuration. Method: A typical iliac artery model was reconstructed, and two models were manufactured using three-dimensional printing technology. The novel IBD was deployed into one iliac artery model by an experienced vascular surgeon. A mock circulation loop (MCL) and a computational fluid dynamics (CFD) simulation were used to investigate the haemodynamic parameters of the iliac models without (Model A) and with (Model B) the IBD. A morphological analysis was conducted using computed tomography angiography and medical endoscopy. The flow distribution rate (FDR) and energy loss (EL) were used to quantify IBD performance. Results: The FDR of the right internal iliac artery in the MCL of Model A and Model B was 18.88 ± 0.12% and 16.26 ± 0.09%, respectively (P = 0.0013). The FDR of the right internal iliac artery in the CFD simulation of Model A and Model B was 17.52 and 14.49%, respectively. The EL of Model A was greater than Model B in both the MCL and the CFD simulation. Compared with Model A, Model B had a larger region (8.46 vs. 3.64%) with a relative residence time of >20 Pa-1 at peak systole. Meanwhile, the area where the oscillatory flow index was >0.4 was significantly smaller in Model B than in Model A (0.46 vs. 0.043%). The region with an average wall shear stress of >4 Pa was greater in Model B than in Model A (0 vs. 0.22%). Conclusion: The MCL and CFD simulation showed that the novel IBD had little impact on the FDR and EL of the iliac artery models. However, the IBD might be an effective tool for the treatment of abdominal aortic/iliac aneurysms that extend into branches. Further investigations are warranted to confirm whether this IBD could be useful in the clinic.

9.
J Org Chem ; 86(6): 4448-4456, 2021 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-33651601

RESUMEN

A sulfa-Michael/aldol/lactonization cascade reaction has been established to construct isotetronic acid-fused thiochromanes in a highly stereoselective fashion (≥11:1 dr, 35-98% ee). The tricyclic products were obtained in 35-99% isolated yields in the presence of a bifunctional squaramide. Three reactive sites of ß,γ-unsaturated α-ketoester, including the less-explored ester carbonyl group, were sequentially utilized to construct two fused heterocycles in a one-pot operation.


Asunto(s)
Ésteres , Catálisis , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA