Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
J Orthop Surg Res ; 19(1): 278, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704574

RESUMEN

BACKGROUND: The surgical treatment of severe and complex adult spinal deformity (ASD) commonly required three-column osteotomy (3-CO), which was technically demanding with high risk of neurological deficit. Personalized three dimensional (3D)-printed guide template based on preoperative planning has been gradually applied in 3-CO procedure. The purpose of this study was to compare the efficacy, safety, and precision of 3D-printed osteotomy guide template and free-hand technique in the treatment of severe and complex ASD patients requiring 3-CO. METHODS: This was a single-centre retrospective comparative cohort study of patients with severe and complex ASD (Cobb angle of scoliosis > 80° with flexibility < 25% or focal kyphosis > 90°) who underwent posterior spinal fusion and 3-CO between January 2020 to January 2023, with a minimum 12 months follow-up. Personalized computer-assisted three-dimensional osteotomy simulation was performed for all recruited patients, who were further divided into template and non-template groups based on the application of 3D-printed osteotomy guide template according to the surgical planning. Patients in the two groups were age- and gender- propensity-matched. The radiographic parameters, postoperative neurological deficit, and precision of osteotomy execution were compared between groups. RESULTS: A total of 40 patients (age 36.53 ± 11.98 years) were retrospectively recruited, with 20 patients in each group. The preoperative focal kyphosis (FK) was 92.72° ± 36.77° in the template group and 93.47° ± 33.91° in the non-template group, with a main curve Cobb angle of 63.35° (15.00°, 92.25°) and 64.00° (20.25°, 99.20°), respectively. Following the correction surgery, there were no significant differences in postoperative FK, postoperative main curve Cobb angle, correction rate of FK (54.20% vs. 51.94%, P = 0.738), and correction rate of main curve Cobb angle (72.41% vs. 61.33%, P = 0.101) between the groups. However, the match ratio of execution to simulation osteotomy angle was significantly greater in the template group than the non-template group (coronal: 89.90% vs. 74.50%, P < 0.001; sagittal: 90.45% vs. 80.35%, P < 0.001). The operating time (ORT) was significantly shorter (359.25 ± 57.79 min vs. 398.90 ± 59.48 min, P = 0.039) and the incidence of postoperative neurological deficit (5.0% vs. 35.0%, P = 0.018) was significantly lower in the template group than the non-template group. CONCLUSION: Performing 3-CO with the assistance of personalized 3D-printed guide template could increase the precision of execution, decrease the risk of postoperative neurological deficit, and shorten the ORT in the correction surgery for severe and complex ASD. The personalized osteotomy guide had the advantages of 3D insight of the case-specific anatomy, identification of osteotomy location, and translation of the surgical planning or simulation to the real surgical site.


Asunto(s)
Osteotomía , Impresión Tridimensional , Humanos , Estudios Retrospectivos , Osteotomía/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Estudios de Cohortes , Escoliosis/cirugía , Escoliosis/diagnóstico por imagen , Cifosis/cirugía , Cifosis/diagnóstico por imagen , Fusión Vertebral/métodos , Índice de Severidad de la Enfermedad , Curvaturas de la Columna Vertebral/cirugía , Curvaturas de la Columna Vertebral/diagnóstico por imagen , Medicina de Precisión/métodos , Resultado del Tratamiento , Adulto Joven
2.
Adv Mater Technol ; 8(21)2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-39130370

RESUMEN

This study aims to develop an ex vivo organ-on-a-chip model, intervertebral Disc-on-a-ChipMF, to investigate integrated effects of mechanical loading and nutrition on disc health. The system consists of a detachable multilayer microfluidic chip, a Computer-Arduino-based control system, and a mechanical loading unit, which were optimized for accurate axial force measurement and the maintenance of a 21-day ex vivo disc culture. To ensure accuracy of axial force, we optimized the axial mechanical loading regimen, used the Computer-Arduino-based system and low-profile force sensors (LPFS) to control the mechanical loading unit, and modeled the force distribution by using computational simulation. A 21-day ex vivo disc culture was demonstrated using the Disc-on-a-ChipMF system, with optimized mechanical loading (0.02 MPa at 1Hz, 1.5 hr/day) and flow rate (1 µL/min). The structural integrity, collagen breakdown, catabolic enzyme activities, and disc cell and collagen alignment revealed that the on-chip cultured discs exhibited a preferred disc health similar to that of native discs for up to 21 days, while discs in a static culture showed detrimental degenerative changes. The mouse Disc-on-a-ChipMF system mimics in vivo disc microenvironment and provides a valuable platform for studying the effects of various factors on disc health and degeneration and testing new therapies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA