RESUMEN
Free thyroid hormone (FTH) serves as the preferred indicator for the clinical assessment of thyroid function, mainly encompassing free thyroxine and free triiodothyronine. The immunoassay commonly employed in the clinical setting exhibits certain unresolvable deficiencies. The results of over 5,500 clinical laboratories for FTH from China in 2024 demonstrated that the outcomes of immunoassay were not comparable, with robust CVs calculated in accordance with ISO 13528 ranging from 13.82% to 21.42%. Establishing reference methods is an important tool to achieve accurate and comparable results of free hormones. Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) holds a distinct advantage in the precise detection of small molecules, and two reference methods for free thyroxine based on LC-MS/MS are included in the JCTLM list. This article conducts a comprehensive review of the detection methods and standardization of FTH. It presents the metabolism of thyroid hormones, the significance of detection, the techniques, and application examples of free thyroid hormone assays, and deliberates on the current status, prospects, and recommendations for the standardization of FTH assays. Immunoassay and LC-MS/MS, as significant techniques for FTH detection, are predominantly emphasized in the case references. Ultrafiltration and equilibrium dialysis, which are utilized to separate FTH, are also addressed. This article aims to discuss the status quo of FTH detection and clarify the advantages of LC-MS/MS in FTH detection, propose that LC-MS/MS can be utilized as an auxiliary validation method or alternative method in clinical applications, and offer suggestions for the standardization of testing results.
RESUMEN
Many biophysical techniques, such as single-molecule fluorescence correlation spectroscopy, Förster resonance energy transfer, and fluorescence anisotropy, measure the translation and rotation of biomolecules to quantify molecular processes at the nanoscale. These methods often simplify data analysis by assuming isotropic rotational diffusion, e.g., that molecules wobble within a circular cone. This simplification ignores the anisotropy present in many biological contexts that may cause molecules to exhibit different degrees of diffusion in different directions. Here, we loosen this assumption and establish a theoretical framework for describing and measuring anisotropic rotational diffusion using fluorescence imaging. We show that anisotropic wobble is directly quantified by the eigenvalues of a 3-by-3 positive-semidefinite Hermitian matrix M consisting of the second-order moments of a molecule's transition dipole µ. This formalism enables us to model the influence of unavoidable shot noise using a Hermitian perturbation matrix E; the eigenvalues of E directly bound errors in measurements of wobble via Weyl's inequality. Quantifying various perturbations E reveals that anisotropic wobble measurements are generally more sensitive to errors compared to quantifying isotropic wobble. Moreover, severe shot noise can induce negative eigenvalues in estimates of M, thereby causing the anisotropic wobble measurement to fail. Our analysis, using Fisher information, shows that techniques with worse orientation measurement sensitivity experience stronger perturbations E and require larger signal to background ratios to measure anisotropic rotational diffusion accurately. Our work provides deep insights for improving the state of the art in imaging the orientations and anisotropic rotational diffusion of single molecules.
RESUMEN
Background: Cancer-associated fibroblasts (CAFs) within the tumor microenvironment (TME) can interact with tumor parenchymal cells to promote tumor growth and migration. Fibroblast activation protein (FAP) expressed by CAFs can be targeted with positron emission tomography (PET) tracers, but studies on FAP expression patterns in intracranial tumors remain scarce. We aimed to evaluate FAP expression patterns in intracranial tumors with gallium-68 FAP inhibitor-04 (68Ga-FAPi-04) and immunohistochemical staining and to observe the interactions between CAFs and tumor cells with a head-to-head comparison of 68Ga-FAPi-04 and fluoride-18 fluoroethyl-L-tyrosine (18F-FET) for PET quantification analysis. Methods: We prospectively enrolled 22 adult patients with intracranial mass lesions. 68Ga-FAPi-04 and 18F-FET PET-computed tomography (PET/CT) brain imaging were applied before surgery. Maximal tumor-to-brain ratio (TBRmax), metabolic tumor volume (MTV), and total lesion tracer uptake (TLU) was obtained, and different thresholds were used for 68Ga-FAPi-04-positive lesion delineation owing to the lack of relevant guidelines. The MTV and TLU ratios of both tracers were calculated. Linear regression was applied to observe the differential efficacy of semiquantitative PET parameters. Results: A total of 22 patients with a mean age of 50±13 years (range, 27-69 years) were enrolled. Heterogeneous patterns of 68Ga-FAPi-04 uptake [median of maximal standardized uptake value (SUVmax) =3.8; range, 0.1-19.1] were found. More malignant tumors, including brain metastasis, glioblastoma, and medulloblastoma, generally exhibited more significant 68Ga-FAPi-04 uptake than did the less malignant tumors, while the SUVmax and TBRmax exhibited nonsignificant differences across three intracranial lesion groups of primary brain tumor, brain metastasis, and noncancerous disease (SUVmax: P=0.092; TBRmax: P=0.189). Immunohistochemistry staining showed different stromal FAP expression status in various intracranial lesions. In 15 patients with positive 68Ga-FAPi-04 intracranial tumor uptake, the MTVFAPi:MTVFET ratio had differential efficacy in various types of intracranial tumors [95% confidence interval (CI): 0.572-7.712; P=0.027], and further quantification analyses confirmed the differential ability of the MTVFAPi:MTVFET ratio (95% CI: -0.045 to 11.013, P=0.052; 95% CI: 0.044-17.903, P=0.049; 95% CI: -1.131 to 30.596, P=0.065) with different isocontour volumetric thresholds. Conclusions: This head-to-head study demonstrated heterogeneous FAP expression in intracranial tumors. The FAP expression volume percentage in tumor parenchyma may therefore offer benefit with respect to differentiating between intracranial tumor types.
RESUMEN
Amyloid-beta (Aß42) aggregates are characteristic Alzheimer's disease signatures, but probing how their nanoscale architectures influence their growth and decay remains challenging using current technologies. Here, we apply time-lapse single-molecule orientation-localization microscopy (SMOLM) to measure the orientations and rotational "wobble" of Nile blue (NB) molecules transiently binding to Aß42 fibrils. We correlate fibril architectures measured by SMOLM with their growth and decay over the course of 5 to 20 min visualized by single-molecule localization microscopy (SMLM). We discover that stable Aß42 fibrils tend to be well-ordered and signified by well-aligned NB orientations and small wobble. SMOLM also shows that increasing order and disorder are signatures of growing and decaying fibrils, respectively. We also observe SMLM-invisible fibril remodeling, including steady growth and decay patterns that conserve ß-sheet organization. SMOLM reveals that increased fibril architectural heterogeneity is correlated with dynamic remodeling and that large-scale fibril remodeling tends to originate from strongly heterogeneous local regions.
RESUMEN
OBJECTIVES: Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients. METHODS: Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared. RESULTS: Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6â¯%, 4.6 and 14.9â¯%, 8.3 and 25.7â¯%, and 10.0 and 34.4â¯% for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2â¯%, 2.5-14.7â¯%, 9.9-31.0â¯%, and 10.0-35.5â¯%, respectively. CONCLUSIONS: The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.
Asunto(s)
Aldosterona , Renina , Aldosterona/sangre , Renina/sangre , Humanos , China , Laboratorios Clínicos , Análisis Químico de la Sangre/normas , Análisis Químico de la Sangre/métodos , Espectrometría de Masas en Tándem , Cromatografía Liquida , Inmunoensayo/normas , Inmunoensayo/métodos , Hiperaldosteronismo/sangre , Hiperaldosteronismo/diagnósticoRESUMEN
Amyloid-beta (Aß42) aggregates are characteristic signatures of Alzheimer's disease, but probing how their nanoscale architectures influence their growth and decay remains challenging using current technologies. Here, we apply time-lapse single-molecule orientation-localization microscopy (SMOLM) to measure the orientations and rotational "wobble" of Nile blue (NB) molecules transiently binding to Aß42 fibrils. We quantify correlations between fibril architectures, measured by SMOLM, and their growth and decay visualized by single-molecule localization microscopy (SMLM). We discover that stable Aß42 fibrils tend to be well-ordered, signified by well-aligned NB orientations and small wobble. SMOLM also shows that increasing order and disorder are signatures of growing and decaying Aß42 fibrils, respectively. We also observe SMLM-invisible fibril remodeling, including steady growth and decay patterns that conserve ß-sheet organization. SMOLM reveals that increased heterogeneity in fibril architectures is correlated with more dynamic remodeling and that large-scale fibril remodeling tends to originate from local regions that exhibit strong heterogeneity.
RESUMEN
BACKGROUND: This study aims to investigate the impact of age and sex on high-sensitivity cardiac troponin T (hs-cTnT) and establish 99th percentile upper reference limits (URLs) in older individuals utilizing large-scale real-world data. METHODS: 40,530 outpatient hs-cTnT results were obtained from the laboratory database from January 1, 2018, to December 31, 2023. Our study included 4,199 elderly outpatients (aged ≥ 60) without cardiovascular disease or other heart-related chronic conditions. Nested analysis of variance was used to explore the necessity of partitioning reference intervals (RIs) by sex and age groups. RIs were established by the refineR algorithm and assessed based on ≤ 10% test results of validation data set outside the new RIs. RESULTS: RIs for hs-cTnT in the older population needed to be partitioned by sex and age groups ([standard deviation ratio] SDRage = 0.75; SDRsex = 0.49). URLs in older Chinese adults were 21.8 ng/L for males, 16.5 ng/L for females, and 20.7 ng/L for the overall participant group. URLs for males aged 60-69, 70-79, and ≥ 80 were 13.7, 19.4, and 31.0 ng/L, respectively. Female values were 10.1, 17.2, and 22.0 ng/L. Importantly, manufacturer-reported RIs do not suffice for Chinese individuals aged ≥ 70. Validation data showed that 2.7-5.2% of test results fell outside the new RIs, confirming the validity of the results. CONCLUSION: This study establishes age- and sex-specific 99th percentile URLs for hs-cTnT in Chinese older individuals, thereby enhancing the accuracy of clinical assessments.
Asunto(s)
Minería de Datos , Troponina T , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Edad , Pueblo Asiatico , China , Minería de Datos/métodos , Pueblos del Este de Asia , Valores de Referencia , Factores Sexuales , Troponina T/sangreRESUMEN
Synthetic peptides that self-assemble into cross-ß fibrils are versatile building blocks for engineered biomaterials due to their modularity and biocompatibility, but their structural and morphological similarities to amyloid species have been a long-standing concern for their translation. Further, their polymorphs are difficult to characterize by using spectroscopic and imaging techniques that rely on ensemble averaging to achieve high resolution. Here, we utilize Nile red (NR), an amyloidophilic fluorogenic probe, and single-molecule orientation-localization microscopy (SMOLM) to characterize fibrils formed by the designed amphipathic enantiomers KFE8L and KFE8D and the pathological amyloid-beta peptide Aß42. Importantly, NR SMOLM reveals the helical (bilayer) ribbon structure of both KFE8 and Aß42 and quantifies the precise tilt of the fibrils' inner and outer backbones in relevant buffer conditions without the need for covalent labeling or sequence mutations. SMOLM also distinguishes polymorphic branched and curved morphologies of KFE8, whose backbones exhibit much more heterogeneity than those of typical straight fibrils. Thus, SMOLM is a powerful tool to interrogate the structural differences and polymorphism between engineered and pathological cross-ß-rich fibrils.
Asunto(s)
Péptidos beta-Amiloides , Microscopía , Conformación Proteica en Lámina beta , Estructura Secundaria de Proteína , Péptidos beta-Amiloides/química , Amiloide/químicaRESUMEN
BACKGROUND: This study assessed the alternations of kynurenine pathway (KP) and neopterin in type 2 diabetes mellitus (T2DM) and explored possible differential metabolites. METHODS: A fresh residual sera panel was collected from 80 healthy control (HC) individuals and 72 T2DM patients. Metabolites/ratios of interest including tryptophan (TRP), kynurenine (KYN), 5-hydroxytryptamine (5HT), kynurenic acid (KA), xanthurenic acid (XA), neopterin (NEO), KA/KYN ratio and KYN/TRP ratio were determined using a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) metabolomics approach, and the difference between groups was assessed. Supervised orthogonal partial least squares-discriminant analysis and differential metabolite screening with fold change (FC) were performed to identify distinct biomarkers. The diagnostic performance of KP metabolites in T2DM was evaluated. RESULTS: Significant decreases of TRP, 5HT, KA, XA, and KA/KYN and increases of KYN/TRP and NEO in T2DM compared to HC group were observed (P < 0.05). The KP metabolites panel significantly changed between T2DM and HC groups (Q2: 0.925, P < 0.005). 5HT (FC: 0.63, P < 0.01) and NEO (FC: 3.27, P < 0.01) were proven to be distinct differential metabolites. A combined testing of fasting plasma glucose and KYN/TRP showed good value in the prediction of T2DM (AUC: 0.904, 95% CI 0.843-0.947). CONCLUSIONS: The targeted LC-MS/MS metabolomics study is a powerful tool for evaluating the status of T2DM. This study facilitated the application of KP metabolomics into future clinical practice. 5HT and NEO are promising biomarkers in T2DM. KYN/TRP was highly associated with the development of T2DM and may serve as a potential treatment target.
Asunto(s)
Diabetes Mellitus Tipo 2 , Quinurenina , Humanos , Quinurenina/metabolismo , Neopterin , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida con Espectrometría de Masas , Triptófano/metabolismo , BiomarcadoresRESUMEN
OBJECTIVES: To quantitatively assess and compare retinal macular structures of rural-dwelling older adults in China using two different optical coherence tomography (OCT) scanners and to examine their associations with demographic, lifestyle, clinical and ocular factors. DESIGN, SETTING AND PARTICIPANTS: This population-based, cross-sectional study included 971 participants (age ≥60 years) derived from the Multimodal Interventions to Delay Dementia and Disability in Rural China study. We collected data on demographics, lifestyle factors, clinical conditions (eg, cardiovascular disease (CVD)) and ocular factors (eg, visual acuity and spherical equivalent). We used two models of spectral-domain OCT to measure macular parameters in nine Early Treatment Diabetic Retinopathy Study subï¬elds. Data were analysed using the multiple general linear models. RESULTS: Spectralis OCT demonstrated higher macular thickness but a lower macular volume than Primus 200 OCT (p<0.05). Nasal quadrant of the inner and outer subfields was the thickest, followed by superior quadrant. Adjusting for multiple potential confounding variables, older age was significantly correlated with lower average inner and outer macular thicknesses and overall macular volume. Men had higher macular parameters than women. The presence of CVD was correlated with lower central macular thickness (ß=-6.83; 95% CI: -13.08 to -0.58; p=0.032). Middle school or above was associated with higher average inner macular thickness (ß=7.85; 95% CI: 1.14 to 14.55; p=0.022) and higher spherical equivalent was correlated with lower average inner macular thickness (ß=-1.78; 95% CI: -3.50 to -0.07; p=0.042). CONCLUSIONS: Macular thickness and volume assessed by Spectralis and Primus 200 OCT scanners differ. Older age and female sex are associated with lower macular thickness and volume. Macular parameters are associated with education, CVD and spherical equivalent. TRIAL REGISTERATION NUMBER: MIND-China study (ChiCTR1800017758).
Asunto(s)
Retinopatía Diabética , Tomografía de Coherencia Óptica , Masculino , Humanos , Femenino , Anciano , Persona de Mediana Edad , Estudios Transversales , Tomografía de Coherencia Óptica/métodos , Retina/diagnóstico por imagen , Refracción OcularRESUMEN
OBJECTIVES: The standardization of cystatin C (CysC) measurement has received increasing attention in recent years due to its importance in estimating glomerular filtration rate (GFR). Mass spectrometry-based assays have the potential to provide an accuracy base for CysC measurement. However, a precise, accurate and sustainable LC-MS/MS method for CysC is still lacking. METHODS: The developed LC-MS/MS method quantified CysC by detecting signature peptide (T3) obtained from tryptic digestion. Stable isotope labeled T3 peptide (SIL-T3) was spiked to control matrix effects and errors caused by liquid handling. The protein denaturation, reduction and alkylation procedures were combined into a single step with incubation time of 1â¯h, and the digestion lasted for 3.5â¯h. In the method validation, digestion time-course, imprecision, accuracy, matrix effect, interference, limit of quantification (LOQ), carryover, linearity, and the comparability to two routine immunoassays were evaluated. RESULTS: No significant matrix effect or interference was observed with the CysC measurement. The LOQ was 0.21â¯mg/L; the within-run and total imprecision were 1.33-2.05â¯% and 2.18-3.90â¯% for three serum pools (1.18-5.34â¯mg/L). The LC-MS/MS method was calibrated by ERM-DA471/IFCC and showed good correlation with two immunoassays traceable to ERM-DA471/IFCC. However, significant bias was observed for immunoassays against the LC-MS/MS method. CONCLUSIONS: The developed LC-MS/MS method is robust and simpler and holds the promise to provide an accuracy base for routine immunoassays, which will promote the standardization of CysC measurement.
Asunto(s)
Cistatina C , Cromatografía Líquida con Espectrometría de Masas , Humanos , Cistatina C/sangre , Inmunoensayo/métodos , Límite de Detección , Cromatografía Líquida con Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodosRESUMEN
PURPOSE: Determination of isocitrate dehydrogenase (IDH) genotype is crucial in the stratification of diagnosis and prognostication in diffuse gliomas. We sought to build and validate radiomics models and clinical features incorporated nomogram for preoperative prediction of IDH mutation status and WHO grade of diffuse gliomas with L-[methyl-11C] methionine ([11C]MET) PET/CT imaging according to the 2016 WHO classification of tumors of the central nervous system. METHODS: Consecutive 178 preoperative [11C]MET PET/CT images were retrospectively studied for radiomics analysis. One hundred six patients from PET scanner 1 were used as training dataset, and 72 patients from PET scanner 2 were used for validation dataset. [11C]MET PET and integrated CT radiomics features were extracted, respectively; three independent predictive models were built based on PET features, CT features, and combined PET/CT features, respectively. The SelectKBest method, Spearman correlation analysis, Least Absolute Shrinkage and Selection Operator (LASSO) regression, and machine learning algorithms were applied for feature selection and model building. After filtering the satisfactory predictive model, key clinical features were incorporated for the nomogram establishment. RESULTS: The combined [11C]MET PET/CT radiomics model, which consisted of four PET features and eight integrated CT features, was significantly associated with IDH genotype (p < 0.0001 for both training and validation datasets). Nomogram based on the [11C]MET PET/CT radiomics score, patients' age, and dichotomous tumor location status showed satisfactory discrimination capacity, and the AUC was 0.880 (95% CI, 0.726-0.998) in the training dataset and 0.866 (95% CI, 0.777-0.956) in the validation dataset. In IDH stratified WHO grade prediction, the final radiomics model consists of four PET features and two CT features had reasonable and stable differential efficacy of WHO grade II and III patients from grade IV patients in IDH-wildtype patients, and the AUC was 0.820 (95% CI, 0.541-1.000) in the training dataset and 0.766 (95% CI, 0.612-0.921) in the validation dataset. CONCLUSION: [11C]MET PET radiomics features could benefit non-invasive IDH genotype prediction, and integrated CT radiomics features could enhance the efficacy. Radiomics and clinical features incorporation could establish satisfactory nomogram for clinical application. This non-invasive predictive investigation based on our consecutive cohort from two PET scanners could provide the perspective to observe the differential efficacy and the stability of radiomics-based investigation in untreated diffuse gliomas.
Asunto(s)
Neoplasias Encefálicas , Glioma , Humanos , Isocitrato Deshidrogenasa/genética , Estudios de Cohortes , Metionina , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiómica , Radioisótopos de Carbono , Glioma/diagnóstico por imagen , Glioma/genética , Glioma/patología , Racemetionina , Mutación , Organización Mundial de la SaludRESUMEN
OBJECTIVES: This study aims to evaluate the commutability of external quality assessment (EQA) materials and candidate reference materials (RMs) for plasma renin activity (PRA) assay. METHODS: Commutabilities of 16 candidate RMs were measured along with 40 clinical samples by the four different routine PRA assays, including three LCâMS/MS assays and one chemiluminescence immunoassay. Sixteen candidate RMs included native/spiked human plasma pools (small-scale pools with <50 individuals) and current EQA materials (large-scale pools with >1,000 individuals). Difference in bias approach and linear regression with prediction interval approach were adopted to determine the commutability. Two-way variance analysis was used to estimate the effects of spiked and pool size on the commutability. Stability and homogeneity studies were performed. RESULTS: Precision and correlation performance of all assays was acceptable. In the difference in bias approach, the commutability results were not satisfactory (noncommutability: 14/16) and significant sample-specific effects were detected in assay pairs using different incubation buffers. For the prediction interval approach, no commutability was observed in the spiked small-scale pools; EQA materials (4/9) had more satisfactory commutability among all assays than the small-scale pools (2/7); RMs of large-scale pools tend to have better commutability no matter spiked or not. CONCLUSIONS: Commutable RMs were obtainable but challenging. Current EQA materials with relatively good commutability, stability, and homogeneity were appropriate RMs. Large-scale pools are tending to be commutable. Spiking in small-scale pools was not suggested to prepare RMs. MPs adopting a uniform incubation buffer would be preferable for further commutability research.
Asunto(s)
Renina , Espectrometría de Masas en Tándem , Humanos , Estándares de Referencia , Cromatografía Liquida , SesgoRESUMEN
BACKGROUND: This study aims to investigate serological characteristics of kynurenine pathway (KP) metabolites in healthy controls (HC) and gout patients and explore possible differential metabolites. METHODS: A total of 191 individual fresh residual sera was collected from 129 HC and 62 gout patients. A liquid chromatography-tandem mass spectrometry method was fully validated to measure 6 metabolites, including tryptophan (TRP), kynurenine (KYN), 5-hydroxytryptamine (5HT), kynurenic acid (KA), xanthurenic acid (XA), and neopterin (NEO). Supervised orthogonal partial least squares-discriminant analysis (OPLS-DA) and differential metabolite screening with fold change (FC) were performed to identify intrinsic variations and differential levels of KP metabolites between the HC and gout groups. Logistic regression was used to assess the contributions of KP metabolites to gout. RESULTS: There were significant decreases of TRP, 5HT, XA, and NEO and increases of KYN, KA, KA/KYN, and KYN/TRP in gout patients compared to the HC group (all p < 0.05). KP metabolites of the gout group showed good discrimination from those of the HC group (Q2: 0.892). Two distinct different metabolites were identified in gout, i.e., XA (FC: 0.56, p < 0.01) and NEO (FC: 0.34, p < 0.01). Of the KP metabolites, KYN was strongly associated with gout (OR: 7.91, p < 0.01). CONCLUSIONS: Abnormal levels of serum KP metabolites were observed in gout. XA and NEO are promising biomarkers that were relevant to the status of gout. The level of KYN could be an attractive checkpoint for the management of gout. Continuous monitoring of KP metabolism in gout provides new opportunities to predict therapeutic efficacy and prognosis.
RESUMEN
Synthetic peptides that self-assemble into cross-ß fibrils have remarkable utility as engineered biomaterials due to their modularity and biocompatibility, but their structural and morphological similarity to amyloid species has been a long-standing concern for their translation. Further, their polymorphs are difficult to characterize using spectroscopic and imaging techniques that rely on ensemble averaging to achieve high resolution. Here, we utilize single-molecule orientation-localization microscopy (SMOLM) to characterize fibrils formed by the designed amphipathic enantiomers, KFE8L and KFE8D, and the pathological amyloid-beta peptide Aß42. SMOLM reveals that the orientations of Nile red, as it transiently binds to both KFE8 and Aß42, are consistent with a helical (bilayer) ribbon structure and convey the precise tilt of the fibrils' inner and outer backbones. SMOLM also finds polymorphic branched and curved morphologies of KFE8 whose backbones exhibit much more heterogeneity than those of more typical straight fibrils. Thus, SMOLM is a powerful tool to interrogate the structural differences and polymorphism between engineered and pathological cross ß-rich fibrils.
RESUMEN
BACKGROUND: We investigated the interference of vitamin C (VitC), glycerol fructose, lipoprotein X (LpX) and lipemia on the analysis of serum lipids. METHODS: Serum were collected from 44 patients with VitC infusion, serum lipid concentrations before and after VitC auto-oxidation were compared. Serum of 31 patients with glycerol fructose infusion were collected, triglycerides (TG) measured by glycerol blanking and non-blanking reagents were compared. Forty-four serum samples suspected to contain LpX were collected, LDL-C measured by reagents from five manufacturers were compared. Lipemia samples were collected, LDL-C measured using five different reagents were compared. The interference rate was considered unacceptable if it was greater than 1/2 total allowable error (TEa). RESULTS: In patients with VitC infusion, the interference rates of TG and total cholesterol (TC) were -59% (-123%, -28%) and -15% (-21%, -11%), respectively. In patients with glycerol fructose infusion, the interference rate of TG was 13% (4%, 113%). LpX interference led to increased LDL-C results for most reagents. Lipemia caused great interference with LDL-C analysis. CONCLUSION: VitC, glycerol fructose, LpX and lipemia significantly interfered with lipid assays. The reagent formulation should be improved to get reliable results.
Asunto(s)
Ácido Ascórbico , Glicerol , Humanos , LDL-Colesterol , Bioensayo , Fructosa , TriglicéridosRESUMEN
OBJECTIVES: To find suitable external quality assessment (EQA) materials for serum C-peptide, we evaluated the commutability of five types of processed materials. METHODS: Seventy-four individual serum samples and 12 processed samples including three EQA samples currently in use, frozen human serum pools (FHSP), and three other kinds of processed samples were prepared by dissolving WHO International Standard Reagent for C-peptide (WHO ISR 13/146) in three different matrixes: 0.05â¯% bovine serum albumin, fetal bovine serum and human serum pools. Samples were analyzed using the isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method and six widely used immunoassays. The commutabilities of processed materials were assessed according to the difference in bias approach recommended by the IFCC. And the short- and long-term stability of FHSP samples at different temperatures were also evaluated. RESULTS: Out of the five kinds of processed materials, FHSP samples were commutable on most assays. In contrast, the EQA materials currently in use were only commutable on a few immunoassays. Additionally, processed materials derived from WHO ISR 13/146 were found to be un-commutable on over half of immunoassays. The FHSP samples could be stably stored at 4 and -20⯰C for at least 16 days, and at -80⯰C for at least 1 year, but at room temperature only for 12â¯h. CONCLUSIONS: With clarified commutability and stability information, the human serum pool samples along with the developed ID-LC-MS/MS method could be used in the EQA program to promote the comparability among laboratories for C-peptide measurement in China.
Asunto(s)
Laboratorios , Espectrometría de Masas en Tándem , Humanos , Péptido C , Cromatografía Liquida , Sesgo , Estándares de ReferenciaRESUMEN
OBJECTIVES: This study aims to investigate and update the consistency and comparability of plasma renin activity (PRA) assays in measuring clinical samples. The contributions of recalibration, blank subtraction, and incubation strategies to interchangeability were also explored. METHODS: Five different laboratories were evaluated using forty-six individual plasma samples, including four liquid chromatography-tandem mass spectrometry (LCâMS/MS) assays and one chemiluminescence immunoassay (CLIA). Spearman correlation coefficient (R), Passing-Bablok regression, and BlandâAltman plot analyses were used to evaluate the consistency among assays. Consistency before and after recalibration, blank subtraction, and incubation strategy unification was compared. RESULTS: A good correlation was observed among all assays (R>0.93). None of the samples measured by all assays showed coefficient variation (CV) <10â¯%, and 37â¯% of samples showed overall CVs >20â¯%. The 95â¯% confidence intervals (CIs) for slopes did not contain 1 for most assay pairs. Large relative biases (-85.1-104.2â¯%) were found, and 76â¯% (52-93â¯%) of samples had unacceptable biases. Recalibration reduced the calibration bias. Ignoring blank subtraction improved the comparability across all assays while unifying incubation did not. CONCLUSIONS: The interchangeability of PRA measurement was unsatisfying. Harmonization on calibrator and ignoring blank were recommended. Unifying incubation strategy was unnecessary.
Asunto(s)
Renina , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Calibración , Mediciones Luminiscentes , Inmunoensayo/métodosRESUMEN
OBJECTIVES: Except for the large bias of some measurement systems for serum cystatin C (CysC) measurements, unacceptable imprecision has been observed for the heterogenous system. This study analyzed the external quality assessment (EQA) results in 2018-2021 to provide an insight into the imprecision of CysC assays. METHODS: Five EQA samples were sent to participating laboratories every year. Participants were divided into reagent/calibrator-based peer groups, for which the robust mean of each sample and robust coefficient of variation (CV) were calculated by Algorithm A from ISO 13528. Peers with more than 12 participants per year were selected for further analysis. The limit of CV was determined to be 4.85% based on clinical application requirements. The concentration-related effect on CVs was investigated using logarithmic curve fitting; the difference in medians and robust CVs between instrument-based subgroups was also evaluated. RESULTS: The total number of participating laboratories increased from 845 to 1,695 in four years and heterogeneous systems remained the mainstream (≥85%). Of 18 peers with ≥12 participants, those using homogeneous systems showed relatively steady and small CVs over four years, with the mean four-year CVs ranging from 3.21 to 3.68%. Some peers using heterogenous systems showed reduced CVs over four years, while 7/15 still had unacceptable CVs in 2021 (5.01-8.34%). Six peers showed larger CVs at the low or high concentrations, and some instrument-based subgroups presented greater imprecision than others. CONCLUSIONS: More efforts should be made to improve the imprecision of heterogeneous systems for CysC measurement.
Asunto(s)
Cistatina C , Humanos , Pruebas de Función RenalRESUMEN
BACKGROUND: Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools' commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. METHODS: Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools' stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples' results were analyzed using the Bland-Altman and Passing and Bablok regression analyses. RESULTS: Serum pools were commutable among most assays, the EQA samples-lyophilized serum pools-were non-commutable among most assays. Serum pools can be stably stored at -20°C and -80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays' agreement at middle and high insulin levels, but not at low levels. CONCLUSIONS: Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.