Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Chem ; 61(11): 1391-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26384353

RESUMEN

BACKGROUND: The Department of Defense (DoD) and the Food and Drug Administration (FDA) have collaboratively worked on a pre-Emergency Use Authorization (pre-EUA) process for in vitro diagnostic (IVD) devices, using FDA's regulatory flexibilities under the EUA authorities. The pre-EUA process enables FDA review of data in anticipation of a request for an EUA, advancing US government public health emergency preparedness efforts. METHODS: The IVD device developed to detect Escherichia coli O104:H4, for which an EUA has not been issued, serves as an example to illustrate that process. Specifically, DoD designed real-time PCR assays to target the virulent E. coli strain O104:H4 (etiological agent of the 2011 German outbreak) including: fliC (flagellin), Agg3C (AAF), and rfb (wbwC) on the basis of the published sequences. RESULTS: After development and optimization of these 3 specific assays, a defined protocol was followed to determine and document the sensitivity and specificity of each assay analytically. CONCLUSIONS: FDA reviewed these data and returned commentary on additional required experiments to complete the pre-EUA process and expedite the use of the device should there be an emergency need for an IVD device to detect this virulent E. coli strain before such a test is cleared by FDA.


Asunto(s)
Infecciones por Escherichia coli/diagnóstico , Infecciones por Escherichia coli/microbiología , Escherichia coli/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , ADN Bacteriano/genética , Brotes de Enfermedades , Escherichia coli/genética , Proteínas de Escherichia coli/genética , Proteínas Fimbrias/genética , Flagelina/genética , Galactosiltransferasas/genética , Humanos , Hidrólisis , Límite de Detección , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Análisis de Secuencia de ADN , Estados Unidos , United States Food and Drug Administration
2.
Viruses ; 7(3): 857-72, 2015 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-25710889

RESUMEN

Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM) for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR). The ViroCyt® Virus Counter (VC) 2100 (ViroCyt, Boulder, CO, USA) is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.


Asunto(s)
Ebolavirus/aislamiento & purificación , Carga Viral/métodos , Animales , Humanos , Coloración y Etiquetado/métodos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA