Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.036
Filtrar
Más filtros

Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38746904

RESUMEN

Image-enhanced endoscopy (IEE) has advanced gastrointestinal disease diagnosis and treatment. Traditional white-light imaging has limitations in detecting all gastrointestinal diseases, prompting the development of IEE. In this review, we explore the utility of IEE, including texture and color enhancement imaging and red dichromatic imaging, in pancreatobiliary (PB) diseases. IEE includes methods such as chromoendoscopy, optical-digital, and digital methods. Chromoendoscopy, using dyes such as indigo carmine, aids in delineating lesions and structures, including pancreato-/cholangio-jejunal anastomoses. Optical-digital methods such as narrow-band imaging enhance mucosal details and vessel patterns, aiding in ampullary tumor evaluation and peroral cholangioscopy. Moreover, red dichromatic imaging with its specific color allocation, improves the visibility of thick blood vessels in deeper tissues and enhances bleeding points with different colors and see-through effects, proving beneficial in managing bleeding complications post-endoscopic sphincterotomy. Color enhancement imaging, a novel digital method, enhances tissue texture, brightness, and color, improving visualization of PB structures, such as PB orifices, anastomotic sites, ampullary tumors, and intraductal PB lesions. Advancements in IEE hold substantial potential in improving the accuracy of PB disease diagnosis and treatment. These innovative techniques offer advantages paving the way for enhanced clinical management of PB diseases. Further research is warranted to establish their standard clinical utility and explore new frontiers in PB disease management.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38725874

RESUMEN

Objective: Iodine staining on white light imaging (WLI) is the gold standard for detecting and demarcating esophageal squamous cell carcinoma (ESCC). We examined the effects of texture and color enhancement imaging (TXI) on improving the endoscopic visibility of ESCC under iodine staining. Methods: Twenty ESCC lesions that underwent endoscopic submucosal dissection were retrospectively included. The color difference between ESCC and the surrounding mucosa (ΔEe) on WLI, TXI, and narrow-band imaging was assessed, and ΔEe under 1% iodine staining on WLI and TXI. Furthermore, the visibility grade determined by endoscopists was evaluated on each imaging. Result: The median ΔEe was greater on TXI than on WLI (14.53 vs. 10.71, respectively; p < 0.005). Moreover, the median ΔEe on TXI under iodine staining was greater than the median ΔEe on TXI and narrow-band imaging (39.20 vs. 14.53 vs. 16.42, respectively; p < 0.005 for both). A positive correlation in ΔEe under iodine staining was found between TXI and WLI (correlation coefficient = 0.61, p < 0.01). Moreover, ΔEe under iodine staining on TXI in each lesion was greater than the corresponding ΔEe on WLI. The visibility grade assessed by endoscopists on TXI was also significantly greater than that on WLI under iodine staining (p < 0.01). Conclusions: The visibility of ESCC after iodine staining was greater on TXI than on WLI.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38725875

RESUMEN

Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase-shift method to measure three-dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase-shift method using a stripe pattern projected from a small projecting device to an object. For evaluation, 88 measurement points were inserted in porcine stomach tissue, attached to a half-pipe jig, with an inner radius of 21 mm. The accuracy and precision of the measurement data for our shape measurement system were compared with the data obtained using an Olympus STM6 measurement microscope. The accuracy of the path length of a simulated protruded lesion was evaluated using a plaster model of the curved stomach and graph paper. The difference in height measures between the measurement microscope and measurement system data was 0.24 mm for the 88 measurement points on the curved surface of the porcine stomach. The error in the path length measurement for a lesion on an underlying curved surface was <1% for a 10-mm lesion. The software was developed for the automated calculation of the major and minor diameters of each lesion. The accuracy of our measurement system could improve the accuracy of determining the size of lesions, whether protruded or depressed, regardless of the curvature of the underlying surface.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38817687

RESUMEN

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39144408

RESUMEN

Objectives: We aimed to conduct a systematic review and meta-analysis to assess the value of image-enhanced endoscopy including blue laser imaging (BLI), linked color imaging, narrow-band imaging (NBI), and texture and color enhancement imaging to detect and diagnose gastric cancer (GC) compared to that of white-light imaging (WLI). Methods: Studies meeting the inclusion criteria were identified through PubMed, Cochrane Library, and Japan Medical Abstracts Society databases searches. The pooled risk ratio for dichotomous variables was calculated using the random-effects model to assess the GC detection between WLI and image-enhanced endoscopy. A random-effects model was used to calculate the overall diagnostic performance of WLI and magnifying image-enhanced endoscopy for GC. Results: Sixteen studies met the inclusion criteria. The detection rate of GC was significantly improved in linked color imaging compared with that in WLI (risk ratio, 2.20; 95% confidence interval [CI], 1.39-3.25; p < 0.01) with mild heterogeneity. Magnifying endoscopy with NBI (ME-NBI) obtained a pooled sensitivity, specificity, and area under the summary receiver operating curve of 0.84 (95 % CI, 0.80-0.88), 0.96 (95 % CI, 0.94-0.97), and 0.92, respectively. Similarly, ME-BLI showed a pooled sensitivity, specificity, and area under the curve of 0.81 (95 % CI, 0.77-0.85), 0.85 (95 % CI, 0.82-0.88), and 0.95, respectively. The diagnostic efficacy of ME-NBI/BLI for GC was evidently high compared to that of WLI, However, significant heterogeneity among the NBI studies still existed. Conclusions: Our meta-analysis showed a high detection rate for linked color imaging and a high diagnostic performance of ME-NBI/BLI for GC compared to that with WLI.

6.
J Biomed Opt ; 30(Suppl 1): S13703, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39034959

RESUMEN

Significance: Standardization of fluorescence molecular imaging (FMI) is critical for ensuring quality control in guiding surgical procedures. To accurately evaluate system performance, two metrics, the signal-to-noise ratio (SNR) and contrast, are widely employed. However, there is currently no consensus on how these metrics can be computed. Aim: We aim to examine the impact of SNR and contrast definitions on the performance assessment of FMI systems. Approach: We quantified the SNR and contrast of six near-infrared FMI systems by imaging a multi-parametric phantom. Based on approaches commonly used in the literature, we quantified seven SNRs and four contrast values considering different background regions and/or formulas. Then, we calculated benchmarking (BM) scores and respective rank values for each system. Results: We show that the performance assessment of an FMI system changes depending on the background locations and the applied quantification method. For a single system, the different metrics can vary up to ∼ 35 dB (SNR), ∼ 8.65 a . u . (contrast), and ∼ 0.67 a . u . (BM score). Conclusions: The definition of precise guidelines for FMI performance assessment is imperative to ensure successful clinical translation of the technology. Such guidelines can also enable quality control for the already clinically approved indocyanine green-based fluorescence image-guided surgery.


Asunto(s)
Benchmarking , Imagen Molecular , Imagen Óptica , Fantasmas de Imagen , Relación Señal-Ruido , Imagen Molecular/métodos , Imagen Molecular/normas , Imagen Óptica/métodos , Imagen Óptica/normas , Procesamiento de Imagen Asistido por Computador/métodos
7.
J Environ Sci (China) ; 147: 512-522, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39003067

RESUMEN

To better understand the migration behavior of plastic fragments in the environment, development of rapid non-destructive methods for in-situ identification and characterization of plastic fragments is necessary. However, most of the studies had focused only on colored plastic fragments, ignoring colorless plastic fragments and the effects of different environmental media (backgrounds), thus underestimating their abundance. To address this issue, the present study used near-infrared spectroscopy to compare the identification of colored and colorless plastic fragments based on partial least squares-discriminant analysis (PLS-DA), extreme gradient boost, support vector machine and random forest classifier. The effects of polymer color, type, thickness, and background on the plastic fragments classification were evaluated. PLS-DA presented the best and most stable outcome, with higher robustness and lower misclassification rate. All models frequently misinterpreted colorless plastic fragments and its background when the fragment thickness was less than 0.1mm. A two-stage modeling method, which first distinguishes the plastic types and then identifies colorless plastic fragments that had been misclassified as background, was proposed. The method presented an accuracy higher than 99% in different backgrounds. In summary, this study developed a novel method for rapid and synchronous identification of colored and colorless plastic fragments under complex environmental backgrounds.


Asunto(s)
Monitoreo del Ambiente , Aprendizaje Automático , Plásticos , Espectroscopía Infrarroja Corta , Espectroscopía Infrarroja Corta/métodos , Monitoreo del Ambiente/métodos , Plásticos/análisis , Análisis de los Mínimos Cuadrados , Análisis Discriminante , Color
8.
J Environ Sci (China) ; 148: 602-613, 2025 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39095193

RESUMEN

Airborne microplastics (MPs) are important pollutants that have been present in the environment for many years and are characterized by their universality, persistence, and potential toxicity. This study investigated the effects of terrestrial and marine transport of MPs in the atmosphere of a coastal city and compared the difference between daytime and nighttime. Laser direct infrared imaging (LDIR) and polarized light microscopy were used to characterize the physical and chemical properties of MPs, including number concentration, chemical types, shape, and size. Backward trajectories were used to distinguish the air masses from marine and terrestrial transport. Twenty chemical types were detected by LDIR, with rubber (16.7%) and phenol-formaldehyde resin (PFR; 14.8%) being major components. Three main morphological types of MPs were identified, and fragments (78.1%) are the dominant type. MPs in the atmosphere were concentrated in the small particle size segment (20-50 µm). The concentration of MPs in the air mass from marine transport was 14.7 items/m3 - lower than that from terrestrial transport (32.0 items/m3). The number concentration of airborne MPs was negatively correlated with relative humidity. MPs from terrestrial transport were mainly rubber (20.2%), while those from marine transport were mainly PFR (18%). MPs in the marine transport air mass were more aged and had a lower number concentration than those in the terrestrial transport air mass. The number concentration of airborne MPs is higher during the day than at night. These findings could contribute to the development of targeted control measures and methods to reduce MP pollution.


Asunto(s)
Contaminantes Atmosféricos , Monitoreo del Ambiente , Microplásticos , China , Microplásticos/análisis , Contaminantes Atmosféricos/análisis , Ciudades , Atmósfera/química , Tamaño de la Partícula
9.
J Med Imaging (Bellingham) ; 12(Suppl 1): S13003, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39055549

RESUMEN

Purpose: Use of mechanical imaging (MI) as complementary to digital mammography (DM), or in simultaneous digital breast tomosynthesis (DBT) and MI - DBTMI, has demonstrated the potential to increase the specificity of breast cancer screening and reduce unnecessary biopsies compared with DM. The aim of this study is to investigate the increase in the radiation dose due to the presence of an MI sensor during simultaneous image acquisition when automatic exposure control is used. Approach: A radiation dose study was conducted on clinically available breast imaging systems with and without an MI sensor present. Our estimations were based on three approaches. In the first approach, exposure values were compared in paired clinical DBT and DBTMI acquisitions in 97 women. In the second approach polymethyl methacrylate (PMMA) phantoms of various thicknesses were used, and the average glandular dose (AGD) values were compared. Finally, a rectangular PMMA phantom with a 45 mm thickness was used, and the AGD values were estimated based on air kerma measurements with an electronic dosemeter. Results: The relative increase in exposure estimated from digital imaging and communications in medicine headers when using an MI sensor in clinical DBTMI was 11.9 % ± 10.4 . For the phantom measurements of various thicknesses of PMMA, the relative increases in the AGD for DM and DBT measurements were, on average, 10.7 % ± 3.1 and 11.4 % ± 3.0 , respectively. The relative increase in the AGD using the electronic dosemeter was 11.2 % ± < 0.001 in DM and 12.2 % ± < 0.001 in DBT. The average difference in dose between the methods was 11.5 % ± 3.3 . Conclusions: Our measurements suggest that the use of simultaneous breast radiography and MI increases the AGD by an average of 11.5 % ± 3.3 . The increase in dose is within the acceptable values for mammography screening recommended by European guidelines.

10.
Sci Rep ; 14(1): 19370, 2024 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169048

RESUMEN

Atrial fibrillation (A-fib) is the most common type of heart arrhythmia, typically treated with radiofrequency catheter ablation to isolate the heart from abnormal electrical signals. Monitoring the formation of ablation-induced lesions is crucial for preventing recurrences and complications arising from excessive or insufficient ablation. Existing imaging modalities lack real-time feedback, and their intraoperative usage is in its early stages. A critical need exists for an imaging-based lesion indexing (LSI) method that directly reflects tissue necrosis formation. Previous studies have indicated that spectroscopic photoacoustic (sPA) imaging can differentiate ablated tissues from their non-ablated counterparts based on PA spectrum variation. In this paper, we introduce a method for detecting ablation lesion boundaries using sPA imaging. This approach utilizes ablation LSI, which quantifies the ratio between the signal from ablated tissue and the total tissue signal. We enhance boundary detection accuracy by adapting a regression model-based compensation. Additionally, the method was cross-validated with clinically used intraoperative monitoring parameters. The proposed method was validated with ex vivo porcine cardiac tissues with necrotic lesions created by different ablation durations. The PA-measured lesion size was compared with gross pathology. Statistical analysis demonstrates a strong correlation (R > 0.90) between the PA-detected lesion size and gross pathology. The PA-detected lesion size also exhibits a moderate to strong correlation (R > 0.75) with local impedance changes recorded during procedures. These results suggest that the introduced PA imaging-based LSI has great potential to be incorporated into the clinical workflow, guiding ablation procedures intraoperatively.


Asunto(s)
Ablación por Catéter , Técnicas Fotoacústicas , Animales , Técnicas Fotoacústicas/métodos , Porcinos , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Necrosis/diagnóstico por imagen , Ablación por Radiofrecuencia/métodos
11.
BMC Complement Med Ther ; 24(1): 311, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169368

RESUMEN

BACKGROUND: Insomnia disorder (ID) is one of the most common sleep problems, usually accompanied by anxiety and depression symptoms. Functional magnetic resonance imaging (fMRI) study suggests that both poor sleep quality and negative emotion are linked to the dysregulation of brain network related to emotion processing in ID patients. Acupuncture therapy has been proven effective in improving sleep quality and mood of ID patients, but the involved neurobiological mechanism remains unclear. We aimed to investigate the modulation effect of acupuncture on resting-state functional connectivity (rsFC) of the emotional network (EN) in patients experiencing insomnia. METHODS: A total of 30 healthy controls (HCs) and 60 ID patients were enrolled in this study. Sixty ID patients were randomly assigned to real and sham acupuncture groups and attended resting-state fMRI scans before and after 4 weeks of acupuncture treatment. HCs completed an MRI/fMRI scan at baseline. The rsFC values within EN were calculated, and Hamilton Anxiety Scale (HAMA), Hamilton Depression Scale (HAMD), Pittsburgh Sleep Quality Index (PSQI), Hyperarousal Scale (HAS), and actigraphy data were collected for clinical efficacy evaluation. RESULTS: Resting-state FC analysis showed abnormalities in rsFC centered on the thalamus and dorsolateral prefrontal cortex within EN of ID patients compared to HCs. After real acupuncture treatment, rsFC of the anterior cingulate cortex, hippocampus, and amygdala were increased compared with the sham acupuncture group (p < 0.05, FDR corrected). In real acupuncture group, the rsFC value was decreased between left amygdala and left thalamus after 4 weeks of treatment compared with baseline. A trend of correlation was found that the increased rsFC value between the right amygdala and left hippocampus was positively correlated with the decreased HAMA scores across all ID patients, and the decreased left amygdala rsFC value with the left thalamus was negatively correlated with the increased sleep efficiency in the real acupuncture group. CONCLUSION: Our findings showed that real acupuncture could produce a positive effect on modulating rsFC within network related to emotion processing in ID patients, which may illustrate the central mechanism underlying acupuncture for insomnia in improving sleep quality and emotion regulation. TRIAL REGISTRATION: http://www.chictr.org.cn ., ChiCTR1800015282, 20/03/2018.


Asunto(s)
Terapia por Acupuntura , Imagen por Resonancia Magnética , Trastornos del Inicio y del Mantenimiento del Sueño , Humanos , Trastornos del Inicio y del Mantenimiento del Sueño/terapia , Trastornos del Inicio y del Mantenimiento del Sueño/fisiopatología , Masculino , Femenino , Adulto , Persona de Mediana Edad , Emociones , Encéfalo/fisiopatología , Encéfalo/diagnóstico por imagen
12.
Alzheimers Res Ther ; 16(1): 190, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169442

RESUMEN

BACKGROUND: Alzheimer's disease (AD) is a common, complex and multifactorial disease that may require screening across multiple routes of referral to enable early detection and subsequent future implementation of tailored interventions. Blood- and eye-based biomarkers show promise as low-cost, scalable and patient-friendly tools for early AD detection given their ability to provide information on AD pathophysiological changes and manifestations in the retina, respectively. Eye clinics provide an intriguing real-world proof-of-concept setting to evaluate the performance of these potential AD screening tools given the intricate connections between the eye and brain, presumed enrichment for AD pathology in the aging population with eye disorders, and the potential for an accelerated diagnostic pathway for under-recognized patient groups. METHODS: The BeyeOMARKER study is a prospective, observational, longitudinal cohort study aiming to include individuals visiting an eye-clinic. Inclusion criteria entail being ≥ 50 years old and having no prior dementia diagnosis. Excluded eye-conditions include traumatic insults, superficial inflammation, and conditions in surrounding structures of the eye that are not engaged in vision. The BeyeOMARKER cohort (n = 700) will undergo blood collection to assess plasma p-tau217 levels and a brief cognitive screening at the eye clinic. All participants will subsequently be invited for annual longitudinal follow-up including remotely administered cognitive screening and questionnaires. The BeyeOMARKER + cohort (n = 150), consisting of 100 plasma p-tau217 positive participants and 50 matched negative controls selected from the BeyeOMARKER cohort, will additionally undergo Aß-PET and tau-PET, MRI, retinal imaging including hyperspectral imaging (primary), widefield imaging, optical coherence tomography (OCT) and OCT-Angiography (secondary), and cognitive and cortical vision assessments. RESULTS: We aim to implement the current protocol between April 2024 until March 2027. Primary outcomes include the performance of plasma p-tau217 and hyperspectral retinal imaging to detect AD pathology (using Aß- and tau-PET visual read as reference standard) and to detect cognitive decline. Initial follow-up is ~ 2 years but may be extended with additional funding. CONCLUSIONS: We envision that the BeyeOMARKER study will demonstrate the feasibility of early AD detection based on blood- and eye-based biomarkers in alternative screening settings, and will improve our understanding of the eye-brain connection. TRIAL REGISTRATION: The BeyeOMARKER study (Eudamed CIV ID: CIV-NL-23-09-044086; registration date: 19th of March 2024) is approved by the ethical review board of the Amsterdam UMC.


Asunto(s)
Enfermedad de Alzheimer , Biomarcadores , Diagnóstico Precoz , Humanos , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/diagnóstico por imagen , Biomarcadores/sangre , Estudios Prospectivos , Masculino , Femenino , Anciano , Proteínas tau/sangre , Persona de Mediana Edad , Estudios Longitudinales , Péptidos beta-Amiloides/sangre , Oftalmopatías/diagnóstico , Oftalmopatías/sangre , Oftalmopatías/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Estudios de Cohortes
13.
Front Neurol ; 15: 1443496, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39170078

RESUMEN

Introduction: Traumatic brain injury (TBI) even in the mild form may result in long-lasting post-concussion symptoms. TBI is also a known risk to late-life neurodegeneration. Recent studies suggest that dysfunction in the glymphatic system, responsible for clearing protein waste from the brain, may play a pivotal role in the development of dementia following TBI. Given the diverse nature of TBI, longitudinal investigations are essential to comprehending the dynamic changes in the glymphatic system and its implications for recovery. Methods: In this prospective study, we evaluated two promising glymphatic imaging markers, namely the enlarged perivascular space (ePVS) burden and Diffusion Tensor Imaging-based ALPS index, in 44 patients with mTBI at two early post-injury time points: approximately 14 days (14Day) and 6-12 months (6-12Mon) post-injury, while also examining their associations with post-concussion symptoms. Additionally, 37 controls, comprising both orthopedic patients and healthy individuals, were included for comparative analysis. Results: Our key findings include: (1) White matter ePVS burden (WM-ePVS) and ALPS index exhibit significant correlations with age. (2) Elevated WM-ePVS burden in acute mTBI (14Day) is significantly linked to a higher number of post-concussion symptoms, particularly memory problems. (3) The increase in the ALPS index from acute (14Day) to the chronic (6-12Mon) phases in mTBI patients correlates with improvement in sleep measures. Furthermore, incorporating WM-ePVS burden and the ALPS index from acute phase enhances the prediction of chronic memory problems beyond socio-demographic and basic clinical information. Conclusion: ePVS burden and ALPS index offers distinct values in assessing glymphatic structure and activity. Early evaluation of glymphatic function could be crucial for understanding TBI recovery and developing targeted interventions to improve patient outcomes.

14.
Heliyon ; 10(15): e35502, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170113

RESUMEN

To evaluate the efficacy of the 18F-AlF-NOTA-RGD2 positron emission tomography (PET)/computed tomography (CT) molecular probe for the noninvasive staging of liver fibrosis in mini pigs, a potential alternative to invasive diagnostic methods was revealed. This study used 18F-AlF-NOTA-RGD2 PET/CT imaging of mini pigs to assess liver fibrosis. The methods included synthesis and quality control of the molecular probe, establishment of an animal model of liver fibrosis, blood serum enzymatic tests, histopathological examination, PET/CT imaging, collagen content and expression, and mitochondrial reserve function assessment. The 18F-AlF-NOTA-RGD2 PET/CT molecular probe effectively differentiated various stages of liver fibrosis in mini pigs. Blood serum enzymatic tests revealed distinct stages of liver fibrosis, revealing significant increases in AST, ALT, TBIL, and DBIL levels as fibrosis advanced. Notably, ALT levels increased markedly in severe fibrosis patients. A gradual increase in collagen deposition and increasing α-SMA RNA expression and protein levels effectively differentiated between mild and severe fibrosis stages. Pathological examinations and Sirius Red staining confirmed these findings, highlighting substantial increases in collagen accumulation. PET/CT imaging results aligned with histopathological findings, showing that increased radiotracer uptake correlated with fibrosis severity. Assessments of mitochondrial function revealed a decrease in total liver glutathione content and mitochondrial reserve capacity, especially in patients with severe fibrosis. The 18F-AlF-NOTA-RGD2 PET/CT molecular probe is a promising tool for the noninvasive assessment of liver fibrosis, offering potential benefits over traditional diagnostic methods in hepatology.

15.
Heliyon ; 10(15): e35249, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170121

RESUMEN

Advances in radiotherapy, particularly the exploration of alternative radiation types such as carbon ions have updated our understanding of its effects and applicability on chondrosarcoma cells. Here we compare the optical effects produced by carbon ions (CI) and X-rays (XR) radiations on chondrosarcoma cells nuclei and set an automated method for evaluating the radiation-induced alterations without the need of chemical marking. Hyperspectral images (HSI) of SW1353 chondrosarcoma line carry detectable optical changes of the cells irradiated either with CI or XR compared to non-irradiated ones (REF). The differences between the spectral profiles of CI, XR and REF nuclei classes led to partitioning the HSIs into spectral sub-images. The changes are detected by support vector machine (SVM) classifiers whose performances are evaluated by the most used point metrics: sensitivity (SEN), accuracy (ACC), and precision (PREC), applied on spatial feature values. Specific interaction mechanisms by radiation type reveal distinct subintervals where HSIs changes are more prominent, and the classifiers perform at best. For CI the best classifiers are obtained for sub-images in the interval (424-436 nm), while for XR the best classifiers are obtained for sub-images in the interval (436-445 nm). The classifiers work better with texture features than roughness features in both cases. The classifier with the best SEN point metric in the testing phase is the most suitable to measure the irradiation efficiency irrespective of the radiation type. The altered nuclei are easier to discriminate when irradiated with CI than with XR. The study proves that SVM with optical data offers a rapid, automated, and label-free method for evaluating radiation-induced alterations in chondrosarcoma nuclei, thereby enabling effective analysis of extensive data.

16.
Heliyon ; 10(15): e35440, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170139

RESUMEN

Diffusion-weighted imaging (DWI) is widely utilized for evaluating uterine diseases. However, the prevalent technique, single-shot echo planar imaging (ssEPI), is hindered by notable image distortion and low spatial resolution. Therefore, optimizing uterine DWI sequences is vital for improving image quality. To investigate the efficacy of multiplexed sensitivity encoding (MUSE) combined with reverse polarity gradient (RPG) in enhancing uterine DWI quality and assessing local invasion in endometrial and cervical cancer, we included 149 patients. Each patient underwent DWI of the uterus using ssEPI, MUSE, and RPG-MUSE techniques. We compared these three sequences regarding image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion rate (GDR), ADC values, accuracy in determining the extent of cancer invasion, and the Area Under the Curve (AUC) for identifying endometrial cancer and benign endometrial lesions using ADC values. The results indicated that RPG-MUSE DWI had less artifacts than MUSE and ssEPI (P < 0.05). Lesions were more apparent in MUSE and RPG-MUSE sequences compared to ssEPI (P < 0.05), with RPG-MUSE providing clearer lesion edges (P < 0.05). Additionally, RPG-MUSE DWI demonstrated higher SNR and CNR than ssEPI and MUSE (P < 0.05), along with a lower GDR (P < 0.05). The ADC values did not show significant differences among the three sequences (P > 0.05). Furthermore, the AUC of the ROC for detecting endometrial cancer and benign endometrial lesions using ADC values showed no significant differences across the sequences (P = 0.7609, 0.7186, and 0.8706, respectively). When combining each DWI sequence with T2WI for FIGO staging, RPG-MUSE and MUSE exhibited better alignment with pathology findings compared to ssEPI (P < 0.05). Overall, RPG-MUSE DWI showed fewer artifacts, higher SNR and CNR, reduced geometric distortion, and clearer lesion visualization compared to ssEPI and MUSE, leading to a more precise assessment of endometrial and cervical cancer invasion extent.

17.
Heliyon ; 10(15): e35103, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170274

RESUMEN

Perfusion of porous scaffolds transports cells to the surface to yield cellular constructs for 3D models of disease and for tissue engineering applications. While ceramic scaffolds mimic the structure and composition of trabecular bone, their opacity and tortuous pores limit the penetration of light into the interior. Scaffolds that are both perfusable and amenable to fluorescence microscopy are therefore needed to visualize the spatiotemporal dynamics of cells in the bone microenvironment. In this study, a hybrid injection molding approach was designed to enable rapid prototyping of collector arrays with variable configurations that are amenable to longitudinal imaging of attached human mesenchymal stem cells (hMSCs) using fluorescence microscopy. Cylindrical collectors were arranged in an array that is permeable to perfusion in the xy-plane and to light in the z-direction for imaging from below. The effects of the collector radius, number, and spacing on the collection efficiency of perfused hMSCs was simulated using computational fluid dynamics (CFD) and measured experimentally using fluorescence microscopy. The effect of collector diameter on simulated and experimental cell collection efficiencies followed a trend similar to that predicted by interception theory corrected for intermolecular and hydrodynamic forces for the arrays with constant collector spacing. In contrast, arrays designed with constant collector number yielded collection efficiencies that poorly fit the trend with collector radius predicted by interception theory. CFD simulations of collection efficiency agreed with experimental measurements within a factor of two. These findings highlight the utility of CFD simulations and hybrid injection molding for rapid prototyping of collector arrays to optimize the longitudinal imaging of cells without the need for expensive and time-consuming tooling.

18.
Heliyon ; 10(15): e35203, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170364

RESUMEN

Rationale and objectives: To compare the performance of SS, FOCUS SS, MUSE, and FOCUS MUSE DWI for pulmonary lesions to obtain a better technique for pulmonary DWI imaging. Materials and methods: 44 patients with pulmonary lesions were recruited to perform pulmonary DWI using SS, FOCUS SS, MUSE, and FOCUS MUSE sequences. Then, two radiologists with 12 and 10 years of chest MRI experiences assessed the overall image quality while another two radiologists both with 3 years of experiences evaluated the SNR, DR, and ADC of pulmonary lesions. Using interclass correlation coefficient (ICC) and kappa statistics to assess consistency of readers, Friedman test and Dunn-Bonferroni post hoc were used to calculate the difference between sequences. Mann-Whitney test and ROC curve were used to distinguish malignant from benign lesions. Results: All the assessed variables of the four sequences presented good to excellent intra-/inter-observer consistency. Compared with SS, FOCUS SS and MUSE, FOCUS MUSE demonstrated better image quality, including significantly higher 5-point Likert scale score (P < 0.001) and smaller DR (P < 0.001). SNR was comparable among SS, FOCUS SS, and FOCUS MUSE (P > 0.05) while MUSE presented with significantly higher SNR over them (P < 0.01). ADC of malignant was significantly smaller than that of benign for all the four sequences (P < 0.05). ROC analysis showed relatively better diagnostic performance of FOCUS MUSE (AUC = 0.820) over SS (AUC = 0.748), FOCUS SS (AUC = 0.778), and MUSE (AUC = 0.729) in distinguishing malignant from benign lesions. Conclusion: FOCUS MUSE possessed sufficient SNR and was better over SS, FOUCS SS, and MUSE for characterizing pulmonary lesions.

19.
Heliyon ; 10(15): e35632, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170509

RESUMEN

As lithium-bearing minerals become critical raw materials for the field of energy storage and advanced technologies, the development of tools to accurately identify and differentiate these minerals is becoming essential for efficient resource exploration, mining, and processing. Conventional methods for identifying ore minerals often depend on the subjective observation skills of experts, which can lead to errors, or on expensive and time-consuming techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS) or Optical Emission Spectroscopy (ICP-OES). More recently, Raman Spectroscopy (RS) has emerged as a powerful tool for characterizing and identifying minerals due to its ability to provide detailed molecular information. This technique excels in scenarios where minerals have similar elemental content, such as petalite and spodumene, by offering distinct vibrational information that allows for clear differentiation between such minerals. Considering this case study and its particular relevance to the lithium-mining industry, this manuscript reports the development of an unsupervised methodology for lithium-mineral identification based on Raman Imaging. The deployed machine-learning solution provides accurate and interpretable results using the specific bands expected for each mineral. Furthermore, its robustness is tested with additional blind samples, providing insights into the unique spectral signatures and analytical features that enable reliable mineral identification.

20.
Heliyon ; 10(15): e34910, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170550

RESUMEN

Progressive supranuclear palsy (PSP) is an atypical Parkinsonian syndrome characterized initially by falls and eye movement impairment. This multimodal imaging study aimed at eliciting structural and functional disease-specific brain alterations. T1-weighted and resting-state functional MRI were applied in multi-centric cohorts of PSP and matched healthy controls. Midbrain, cerebellum, and cerebellar peduncles showed severely low gray/white matter volume, whereas thinner cortical gray matter was observed in cingulate cortex, medial and temporal gyri, and insula. Eigenvector centrality analyses revealed regionally specific alterations. Multivariate pattern recognition classified patients correctly based on gray and white matter segmentations with up to 98 % accuracy. Highest accuracies were obtained when restricting feature selection to the midbrain. Eigenvector centrality indices yielded an accuracy around 70 % in this comparison; however, this result did not reach significance. In sum, the study reveals multimodal, widespread brain changes in addition to the well-known midbrain atrophy in PSP. Alterations in brain structure seem to be superior to eigenvector centrality parameters, in particular for prediction with machine learning approaches.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA