Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Nanomaterials (Basel) ; 14(14)2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-39057858

RESUMEN

The high rate of rejection and failure of orthopedic implants is primarily attributed to incomplete osseointegration and stress at the implant-to-bone interface due to significant differences in the mechanical properties of the implant and the surrounding bone. Various surface treatments have been developed to enhance the osteoconductive properties of implants. The aim of this work was the in vitro characterization of titanium alloy modified with a nanocrystalline hydroxyapatite surface layer in relative comparison to unmodified controls. This investigation focused on the behavior of the surface treatment in relation to the physiological environment. Moreover, the osteogenic response of human osteoblasts and adipose stem cells was assessed. Qualitative characterization of cellular interaction was performed via confocal laser scanning microscopy focusing on the cell nuclei and cytoskeletons. Filipodia were assessed using scanning electron microscopy. The results highlight that the HA treatment promotes protein adhesion as well as gene expression of osteoblasts and stem cells, which is relevant for the inorganic and organic components of the extracellular matrix and bone. In particular, cells grown onto HA-modified titanium alloy are able to promote ECM production, leading to a high expression of collagen I and non-collagenous proteins, which are crucial for regulating mineral matrix formation. Moreover, they present an impressive amount of filipodia having long extensions all over the test surface. These findings suggest that the HA surface treatment under investigation effectively enhances the osteoconductive properties of Ti6Al4V ELI.

2.
ACS Biomater Sci Eng ; 10(8): 5381-5389, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39041183

RESUMEN

In this research, we investigate the impact of varying machining parameters [depth of cutting (mm) and spindle rotation speed (rpm)] on the microstructure and electrochemical behavior of Ti6Al4V-ELI dental implants. This comprehensive study employs an approach, leveraging potentiodynamic methods and electrochemical impedance spectroscopy, to analyze corrosion behavior in a phosphate-buffered saline solution. To further deepen our understanding of corrosion kinetics, we used an alternating current circuit model, based on a simple Randles equivalent circuit. This model elucidates the corrosion interface interactions of the Ti6Al4-V-ELI alloy implant within the PBS solution. In addition, our research delves into the microstructural implications of different machining parameters, utilizing scanning electron microscopy and X-ray diffraction (XRD) techniques to reveal significant phase changes. The changes in texture were examined qualitatively by comparing the intensities of the peaks of the XRD pattern. A detailed correlation analysis further links the machining parameters with the corrosion properties of dental implants, offering a comprehensive perspective rarely explored in the existing literature. The results obtained for the three samples showed that the corrosion resistance would be higher by increasing the machining depth and the spindle rotation and that the corrosion current would be lower. As a result, a lower corrosion rate was obtained. Finally, experimental results from electrochemical analyses are compared and discussed.


Asunto(s)
Aleaciones , Implantes Dentales , Titanio , Corrosión , Titanio/química , Aleaciones/química , Ensayo de Materiales , Difracción de Rayos X , Microscopía Electrónica de Rastreo , Espectroscopía Dieléctrica , Diseño de Prótesis Dental , Propiedades de Superficie
3.
Front Bioeng Biotechnol ; 11: 1301454, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38130824

RESUMEN

Introduction: Stress shielding is a common complication following endoprosthetic reconstruction surgery. The resulting periprosthetic osteopenia often manifests as catastrophic fractures and can significantly limit future treatment options. It has been long known that bone plates with lower elastic moduli are key to reducing the risk of stress shielding in orthopedics. Inclusion of open space lattices in metal endoprostheses is believed to reduce the prosthesis modulus potentially improving stress shielding. However, no in vivo data is currently available to support this assumption in long bone reconstruction. This manuscript aims to address this hypothesis using a sheep model of extraarticular bone defect. Methods: Initially, CT was used to create a virtual resection plan of the distal femoral metaphyses and to custom design endoprostheses specific to each femur. The endoprostheses comprised additively manufactured Ti6Al4V-ELI modules that either had a solid core with a modulus of ∼120 GPa (solid implant group) or an open space lattice core with unit cells that had a modulus of 3-6 GPa (lattice implant group). Osteotomies were performed using computer-assisted navigation followed by implantations. The periprosthetic, interfacial and interstitial regions of interest were evaluated by a combination of micro-CT, back-scattered scanning electron microscopy (BSEM), as well as epifluorescence and brightfield microscopy. Results: In the periprosthetic region, mean pixel intensity (a proxy for tissue mineral density in BSEM) in the caudal cortex was found to be higher in the lattice implant group. This was complemented by BSEM derived porosity being lower in the lattice implant group in both caudal and cranial cortices. In the interfacial and interstitial regions, most pronounced differences were observed in the axial interfacial perimeter where the solid implant group had greater bone coverage. In contrast, the lattice group had a greater coverage in the cranial interfacial region. Conclusion: Our findings suggest that reducing the prosthesis modulus by inclusion of an open-space lattice in its design has a positive effect on bone material and morphological parameters particularly within the periprosthetic regions. Improved mechanics appears to also have a measurable effect on the interfacial osteogenic response and osteointegration.

4.
J Mech Behav Biomed Mater ; 140: 105707, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36801786

RESUMEN

Additive manufacturing is widely used in the orthopaedic industry for the high freedom and flexibility in the design and production of personalized custom implants made of Ti6Al4V. Within this context, finite element modeling of 3D printed prostheses is a robust tool both to guide the design phase and to support clinical evaluations, possibly virtually describing the in-vivo behavior of the implant. Given realistic scenarios, a suitable description of the overall implant's mechanical behavior is unavoidable. Considering typical custom prostheses' designs (i.e. acetabular and hemipelvis implants), complex designs involving solid and/or trabeculated parts, and material distribution at different scales hinder a high-fidelity modeling of the prostheses. Moreover, uncertainties in the production and in the material characterization of small parts approaching the accuracy limit of the additive manufacturing technology still exist. While recent works suggest that the mechanical properties of thin 3D-printed parts may be peculiarly affected by specific processing parameters (i.e. powder grain size, printing orientation, samples' thickness) as compared to conventional Ti6Al4V alloy, the current numerical models make gross simplifications in describing the complex material behavior of each part at different scales. The present study focuses on two patient-specific acetabular and hemipelvis prostheses, with the aim of experimentally characterizing and numerically describing the dependency of the mechanical behavior of 3D printed parts on their peculiar scale, therefore, overcoming one major limitation of current numerical models. Coupling experimental activities with finite element analyses, the authors initially characterized 3D printed Ti6Al4V dog-bone samples at different scales, representative of the main material components of the investigated prostheses. Afterwards, the authors implemented the characterized material behaviors into finite element models to compare the implications of adopting scale-dependent vs. conventional scaleindependent approaches in predicting the experimental mechanical behavior of the prostheses in terms of their overall stiffness and the local strain distribution. The material characterization results highlighted the need for a scale-dependent reduction of the elastic modulus for thin samples compared to the conventional Ti6Al4V, which is fundamental to properly describe the overall stiffness and local strain distribution on the prostheses. The presented works demonstrate how an appropriate material characterization and a scale-dependent material description is needed to develop reliable FE models of 3D printed implants characterized by a complex material distribution at different scales.


Asunto(s)
Aleaciones , Prótesis e Implantes , Animales , Perros , Análisis de Elementos Finitos , Porosidad , Diseño de Prótesis , Acetábulo , Impresión Tridimensional
5.
J Biomed Mater Res A ; 111(5): 688-700, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36680491

RESUMEN

The long-term success of intraosseous transcutaneous amputation prostheses (ITAPs) mainly relies on dermal attachment of skin cells to the implant. Otherwise, bacteria can easily penetrate through the interface between the implant and the skin. Therefore, infection at this implant/skin interface remains a significant complication in orthopedic surgeries in which these prostheses are required. Two main strategies were investigated to prevent these potential infection problems which consist in either establishing a strong sealing at the skin/implant interface or on eradicating infections by killing bacteria. In this work, two adhesion peptides, either KRGDS or KYIGSR and one antimicrobial peptide, Magainin 2 (Mag 2), were covalently grafted via phosphonate anchor arms to the surface of the Ti6Al4V ELI (extra low interstitials) material, commonly used to manufacture ITAPs. X-ray photoelectron spectroscopy, contact angle, and confocal microscopy analyses enabled to validate the covalent and stable grafting of these three peptides. Dermal fibroblasts cultures on bare Ti6Al4V ELI surfaces and functionalized ones displayed a good cell adhesion and proliferation on all samples. However, cell spreading and viability appeared to be improved on grafted surfaces, especially for those conjugated with KRGDS and Mag 2. Moreover, the dermal sheet attachment, was significantly higher on surfaces functionalized with Mag 2 as compared to the other surfaces. Therefore, the surface functionalization with the antimicrobial peptide Mag 2 seems to be the best approach for the targeted application, as it could play a dual role, inducing a strong skin adhesion while limiting infections on Ti6Al4V ELI materials.


Asunto(s)
Prótesis e Implantes , Titanio , Titanio/química , Adhesión Celular , Péptidos , Amputación Quirúrgica , Péptidos Antimicrobianos , Propiedades de Superficie
6.
Biomed Mater ; 17(4)2022 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-35447615

RESUMEN

Site-specific drug delivery has the potential to reduce drug dosage by 3- to 5-folds. Given the propensity of drugs used in the treatment of tuberculosis and cancers, the increased drug dosages via oral ingestion for several months to a few years of medication is often detrimental to the health of patients. In this study, the sustained delivery of drugs with multiscale structured novel Neovius lattices was achieved. 3D Neovius open cell lattices (NOCL) with porosities of 40%, 45%, and 50% were fabricated layer-by-layer on the laser bed fusion process. Micron-sized Ti6Al4V ELI powder was used for 3D printing. The Young's modulus achieved from the novel Neovius lattices were in the range of 1.2-1.6 GPa, which is comparable to human cortical bone and helps to improve implant failure due to the stress shielding effect. To provide sustained drug delivery, nanotubes (NTs) were fabricated on NOCLs via high-voltage anodization. The osteogenic agent icariin was loaded onto the NOCL-NT samples and their release profiles were studied for 7 d. A significantly steady and slow release rate of 0.05% per hour of the drug was achieved using NOCL-NT. In addition, the initial burst release of NOCL-NT was 4 fold lower than that of the open-cell lattices without NTs. Cellular studies using MG63 human osteoblast-like cells were performed to determine their biocompatibility and osteogenesis which were analyzed using Calcein AM staining and Alamar Blue after 1, 5, and 7 d. 3D printed NOCL samples with NTs and with Icariin loaded NTs demonstrated a significant increase in cell proliferation as compared to as printed NOCL samples.


Asunto(s)
Aleaciones , Nanotubos , Humanos , Osteogénesis , Porosidad , Impresión Tridimensional , Titanio/química
7.
Prog Orthod ; 23(1): 11, 2022 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-35368222

RESUMEN

BACKGROUND: Mini-screws are widely used as temporary anchorages in orthodontic treatment, but have the disadvantage of showing a high failure rate of about 10%. Therefore, orthodontic mini-screws should have high biocompatibility and retention. Previous studies have demonstrated that the retention of mini-screws can be improved by imparting bioactivity to the surface. The method for imparting bioactivity proposed in this paper is to sequentially perform anodization, periodic pre-calcification, and heat treatments with a Ti-6Al-4V ELI alloy mini-screw. MATERIALS AND METHODS: A TiO2 nanotube-structured layer was formed on the surface of the Ti-6Al-4V ELI alloy mini-screw through anodization in which a voltage of 20 V was applied to a glycerol solution containing 20 wt% H2O and 1.4 wt% NH4F for 60 min. Fine granular calcium phosphate precipitates of HA and octacalcium phosphate were generated as clusters on the surface through the cyclic pre-calcification and heat treatments. The cyclic pre-calcification treatment is a process of immersion in a 0.05 M NaH2PO4 solution and a saturated Ca(OH)2 solution at 90 °C for 1 min each. RESULTS: It was confirmed that the densely structured protrusions were precipitated, and Ca and P concentrations, which bind and concentrate endogenous bone morphogenetic proteins, increased on the surface after simulated body fluid (SBF) immersion test. In addition, the removal torque of the mini-screw fixed into rabbit tibias for 4 weeks was measured to be 8.70 ± 2.60 N cm. CONCLUSIONS: A noteworthy point in this paper is that the Ca and P concentrations, which provide a scaffold suitable for endogenous bone formation, further increased over time after SBF immersion of the APH group specimens. The other point is that our mini-screws have a significantly higher removal torque compared to untreated mini-screws. These results represent that the mini-screw proposed in this paper can be used as a mini-screw for orthodontics.


Asunto(s)
Calor , Oseointegración , Aleaciones , Animales , Materiales Biocompatibles , Tornillos Óseos , Humanos , Conejos , Titanio
8.
Materials (Basel) ; 15(5)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35269102

RESUMEN

Numerical models can be useful for analysis of the ability of structural engineering materials to withstand harsh environmental conditions such as dynamic loading. In the present study, a microstructure-variable-based numerical model for predicting the high strain rate and temperature properties of different microstructures of Ti6Al4V (ELI-Extra Low Interstitial) produced by laser-based powder bed fusion is proposed. The model was implemented in two different subroutines, VUMAT and VUHARD, available in ABAQUS/Explicit for simulating dynamic conditions. The two subroutines were then used to simulate the split Hopkinson pressure bar (SHPB) experiments to study the flow properties of various forms of the direct metal laser sintered Ti6Al4V(ELI) alloy at various conditions of strain rate and temperature. Comparison of the results obtained through simulation and those obtained from experimental testing showed high degrees of correlation and accuracy with correlation coefficients and absolute percentage errors >0.97 and <4%, respectively. The numerical model was also shown to give good predictions of the strain hardening and dynamic recovery phenomena that prevail for deformations at high strain rates and temperatures.

9.
Materials (Basel) ; 15(1)2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-35009518

RESUMEN

Numerical modelling and simulation can be useful tools in qualification of additive manufactured parts for use in demanding structural applications. The use of these tools in predicting the mechanical properties and field performance of additive manufactured parts can be of great advantage. Modelling and simulation of non-linear material behaviour requires development and implementation of constitutive models in finite element analysis software. This paper documents the implementation and verification process of a microstructure-variable based model for DMLS Ti6Al4V (ELI) in two separate ABAQUS/Explicit subroutines, VUMAT and VUHARD, available for defining the yield surface and plastic deformation of materials. The verification process of the implemented subroutines was conducted for single and multiple element tests with varying prescribed loading conditions. The simulation results obtained were then compared with the analytical solutions at the same conditions of strain rates and temperatures. This comparison showed that both developed subroutines were accurate in predicting the flow stress of various forms of DMLS Ti6Al4V (ELI) under different conditions of strain rates and temperatures.

10.
J Mech Behav Biomed Mater ; 123: 104712, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34365098

RESUMEN

The Ti-6Al-4V alloy is the most common biomaterial used for bone replacements and reconstructions. Despite its advantages, the Ti-6Al-4V has a high stiffness that can cause stress-shielding. In this work, we demonstrated that the selective laser melting (SLM) technology could be used to fabricate porosity in Ti-6Al-4V extra low interstitial (ELI) to reduce its stiffness while improving cell adhesion and proliferation. With a porosity of 14.04%, the elastic modulus of the porous Ti-6Al-4V ELI was reduced to 80 GPa. The compressive stress and the 3-point-bending flexural tests revealed that the porous Ti-6Al-4V ELI possessed a brittle characteristic. The additional pores within the beams of the lattice structures of porous Ti-6Al-4V ELI increased its surface arithmetic average roughness, Ra = 3.94 µm. The in vitro cytocompatibility test showed that the SLM printing process and the post-processes did not cause any toxicity in the MC3T3-E1 cells. The in vitro cell proliferation test also showed that the porous Ti-6Al-4V ELI increased the proliferation rate of osteogenic induced MC3T3-E1 cells on Day 7. The findings from this study would provide engineers and researchers with both the mechanical information and biological understanding of SLM printed porous Ti-6Al-4V ELI, and SLM printed dense Ti-6Al-4V ELI towards biomedical applications.


Asunto(s)
Rayos Láser , Titanio , Aleaciones , Ensayo de Materiales , Porosidad , Tecnología
11.
J Mech Behav Biomed Mater ; 113: 104130, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33049622

RESUMEN

In the present study, cellular lattice structures for implant applications are reported for the first-time incorporating copper directly by in-situ alloying in the laser powder bed fusion process. The aim to incorporate 3 at.% Cu into Ti6Al4V(ELI) is selected for improved antibacterial properties while maintaining appropriate mechanical properties. Previously, topologically optimized Ti6Al4V(ELI) lattice structures were successfully designed, manufactured and studied for implant applications. The development of a new alloy produced by in-situ alloying of elemental powder mixture of Ti6Al4V(ELI) and pure Cu powders was used here for the production of identical lattice structures with improved antibacterial properties. One of the same as-designed CAD models was used for the manufacturing of these lattices compared to previous work on pure Ti6Al4V(ELI) lattices, making direct comparison of mechanical properties possible. Similar manufacturability highlights the applicability of this alloying technique to other lattice designs. Microstructural characterization was performed by optical and electron microscopies, as well as microCT. Mechanical characterization was performed by means of compression tests and hardness measurements. Results showed that in-situ alloying with copper leads to the formation of localized Cu-rich regions, refinement of martensitic phase and the formation of CuTi2 intermetallic precipitates, which increased the hardness and strength of the material. Deviations in wall thickness between the as-designed and as-manufactured lattices led to anisotropy of the mechanical properties of the lattices. Higher compressive strength values were obtained when thicker walls were oriented along the loading direction. Nevertheless, alloying with Cu had a higher impact on the compressive strength of lattice structure than the wall thickness deviations. The direct in-situ alloying of copper in Ti6Al4V(ELI) is a promising route for direct manufacturing of antibacterial implants.


Asunto(s)
Aleaciones , Titanio , Rayos Láser , Polvos
12.
Materials (Basel) ; 13(23)2020 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-33255870

RESUMEN

Dislocations play a central role in determining strength and flow properties of metals and alloys. Diffusionless phase transformation of ß→α in Ti6Al4V during the Direct Metal Laser Sintering (DMLS) process produces martensitic microstructures with high dislocation densities. However, heat treatment, such as stress relieving and annealing, can be applied to reduce the volume of these dislocations. In the present study, an analysis of the X-ray diffraction (XRD) profiles of the non-heat-treated and heat-treated microstructures of DMLS Ti6Al4V(ELI) was carried out to determine the level of defects in these microstructures. The modified Williamson-Hall and modified Warren-Averbach methods of analysis were used to evaluate the dislocation densities in these microstructures. The results obtained showed a 73% reduction of dislocation density in DMLS Ti6Al4V(ELI) upon stress relieving heat treatment. The density of dislocations further declined in microstructures that were annealed at elevated temperatures, with the microstructures that were heat-treated just below the ß→α recording the lowest dislocation densities.

13.
Materials (Basel) ; 13(22)2020 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-33213110

RESUMEN

The interplay between a prosthetic and tissue represents an important factor for the fixation of orthopedic implants. Laser texturing tests and electropolishing were performed on two materials used in the fabrication of medical devices, i.e., CoCr and Ti6Al4V-ELI alloys. The material surface was textured with a diode-pumped solid state (DPSS) laser and its effect on the surface quality and material modification, under different combinations of laser power and marking speed, were investigated. Our results indicate that an increment of energy per unit length causes an incremental trend in surface roughness parameters. Additionally, phase transformation on the surface of both alloys was achieved. Chemical analysis by energy dispersive X-ray spectrometer (EDX) shows the formation of (Co(Cr,Mo)) phase and the M23C6 precipitate on the CoCr surface; while quantitative analysis of the X-ray diffractometer (XRD) results demonstrates the oxidation of the Ti alloy with the formation of Ti2O and Ti6O from the reduction of the α-Ti phase. The behaviors were both related with an increase of the energy per unit length. Control of the final surface roughness was achieved by an electropolishing post-treatment, minimizing the as-treated values. After polishing, a reduction of surface roughness parameters was obtained in a range between 3% and 44%, while no changes in chemical composition or present phases were observed.

14.
Materials (Basel) ; 13(12)2020 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-32585940

RESUMEN

Electron beam melting (EBM) is an additive manufacturing technique, which allows forming customized implants that perfectly fit the loss of the anatomical structure of bone. Implantation efficiency depends not only on the implant's functional or mechanical properties but also on its surface properties, which are of great importance with regard to such biological processes as bone regeneration or microbial contamination. This work presents the impact of surface modifications (mechanical polishing, sandblasting, and acid-polishing) of EBM-produced Ti6Al4V ELI implants on essential biological parameters. These include wettability, cytotoxicity toward fibroblast and osteoblast cell line, and ability to form biofilm by Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans. Obtained results indicated that all prepared surfaces exhibited hydrophilic character and the highest changes of wettability were obtained by chemical modification. All implants displayed no cytotoxicity against osteoblast and fibroblast cell lines regardless of the modification type. In turn, the quantitative microbiological tests and visualization of microbial biofilm by means of electron microscopy showed that type of implant's modification correlated with the species-specific ability of microbes to form biofilm on it. Thus, the results of the presented study confirm the relationship between such technological aspects as surface modification and biological properties. The provided data are useful with regard to applications of the EBM technology and present a significant step towards personalized, customized implantology practice.

15.
Materials (Basel) ; 13(7)2020 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-32224887

RESUMEN

Selective Electron Beam Additive Manufacturing (SEBAM) is a promising powder bed fusion additive manufacturing technique for titanium alloys that select particular area melting in different energy density for producing complexly shaped biomedical devices. For most commercial Ti6Al4V porous medical devices, the gradient energy density is usually applied to manufacture in one component during the SEBAM process which selects different energy density built on particular zones. This paper presents gradient energy density base characterization study on an SEBAM built rectangular specimen with a size of 3 mm × 20 mm × 60 mm. The specimen was divided into three zones were built in gradient energy density from 16 to 26.5 J/mm3. The microstructure and mechanical properties were investigated by means of scanning electron microscopy, X-ray diffraction, transmission electron microscopy and mechanical test. The α' martensitic and lack of fusion were observed in the low energy density (LED) built zone. However, no α' phase and no irregular pores were observed both in overlap energy density (OED) and high energy density (HED) built zones located at the middle and bottom of the specimen respectively. This implies the top location and lower energy density have positive effects on the cooling rate but negative effects on densification. The subsequence mechanical properties result also supports this point. Moreover, the intermetallic Ti3Al found in the bottom may be due to the heat transfer from the following melting layer. Furthermore, the microstructure evolution in gradient energy built zones is discussed based on the findings of the microstructure and thermal history correlation analysis.

16.
J Adv Pharm Technol Res ; 11(4): 202-206, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33425705

RESUMEN

Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Sprague Dawley rats were divided into six groups as follows: the treated group, the control group, and the defect group without implant material. In the treated group, the femur bone defect was implanted with as-cast Ti-6Al-4V ELI, 850°C, 950°C, and 1050°C heat-treated Ti-6Al-4V ELI implant material. The rats were euthanized after 30 days postimplantation and evaluated histologically. The results show that the histological scoring of the specimen for femur defect without implant material is 2 (fibrous union and fibrocartilaginous), score with implant as-cast is 2.5, the sample with 850°C heat treatment material is 2.5, 950°C is 2.5, and the temperature at 1050°C is 2.5. The score of 2.5 is between score 2 and score 3: hemorrhage, fibrous union, fibrocartilaginous microhemorrhage, and mineralized cartilage union. In conclusion, there is no effect of different heat treatment temperatures for Ti-6Al-4V ELI implant material in rat bone regeneration's maturation level.

17.
Mater Sci Eng C Mater Biol Appl ; 106: 110289, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31753386

RESUMEN

This paper systematically investigates the biomedical performance of selective laser melted (SLM) porous Ti6Al4V ELI scaffolds for bone implantation through in vitro and in vivo experiments. Scaffolds with pore sizes of 500 µm, 600 µm and 700 µm and porosities of 60% and 70% were manufactured in order to explore the optimum pore size and porosity. Rat bone marrow mesenchymal stem cells (rBMMSCs) were used in the in vitro experiments. Cell Counting Kit-8, live/dead staining and scanning electron microscope were used to assess the cytotoxicity of the porous scaffolds. DNA content quantification was performed to investigate cell proliferation on the porous scaffolds. The osteogenic differentiation of cells was measured by alkaline phosphatase (ALP) activity and osteogenic gene expressions, including bone morphogenetic protein-2 (BMP-2), collagen type 1α1 (COL-1), osteocalcin (OCN), osteopontin (OPN) and runt-related transcription factor-2 (RUNX-2). The Sprague-Dawley (SD) rat models with distal femoral condyles defect were used in the in vivo experiments. Micro-CT analysis and histological analysis were performed after implantation surgery to reveal the bone ingrowth into the porous scaffolds. All in vitro data were analyzed by one-way ANOVA followed by Tukey post hoc tests, in vivo data were analyzed using Kruskall-Wallis ANOVA and Conover-Inman post-hoc test. Based on the in vitro and in vivo experiments, it is found that the porous scaffolds manufactured by SLM did not induce a cytotoxic effect. Among all the porous scaffolds, the scaffold with a pore size of 500 µm and porosity of 60% showed the best cell proliferation and osteogenic differentiation (in vitro experiments) and bone ingrowth (in vivo experiments).


Asunto(s)
Diferenciación Celular , Proliferación Celular , Osteogénesis , Andamios del Tejido/química , Titanio/química , Aleaciones , Animales , Células de la Médula Ósea/citología , Huesos/diagnóstico por imagen , Huesos/patología , Diferenciación Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Subunidad alfa 1 del Factor de Unión al Sitio Principal/genética , Subunidad alfa 1 del Factor de Unión al Sitio Principal/metabolismo , Fracturas Óseas/terapia , Rayos Láser , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/metabolismo , Osteocalcina/genética , Osteocalcina/metabolismo , Osteogénesis/efectos de los fármacos , Porosidad , Ratas , Ratas Sprague-Dawley , Ingeniería de Tejidos , Titanio/toxicidad , Microtomografía por Rayos X
18.
J Mech Behav Biomed Mater ; 71: 295-306, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28376363

RESUMEN

Fatigue resistance and biocompatibility are key parameters for the successful implantation of hard-tissue prostheses, which nowadays are more and more frequently manufactured by selective laser melting (SLM). For this purpose, the present paper is aimed at investigating the effect of post-sintering treatments on the fatigue behavior and biological properties of Ti samples produced by SLM. After the building process, all samples are heat treated to achieve a complete stress relief. The remaining ones are tribofinished with the aim of reducing the surface roughness of the as-sintered condition. Part of the tribofinished samples are then subjected to one of the following post-sintering treatments: (i) shot peening, (ii) hot isostatic pressing (HIP), and (iii) electropolishing. It is found that shot peening and HIP are the most effective treatments to improve the high and the very-high cycle fatigue resistance, respectively. At the same time, they preserve the good biocompatibility ensured by the biomedical Titanium Grade 23.


Asunto(s)
Rayos Láser , Prótesis e Implantes , Titanio/análisis , Aleaciones , Dureza , Humanos , Ensayo de Materiales , Propiedades de Superficie
19.
Clin Oral Implants Res ; 28(8): 893-901, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27317626

RESUMEN

OBJECTIVE: The aim of this preclinical study was to compare histologically and histomorphometrically both sandblasted/acid-etched implant surfaces with or without maintained in an isotonic solution of 0.9% sodium chloride in early stages of osseointegration. MATERIAL AND METHODS: Both implant surfaces were composed of a titanium/aluminum/vanadium alloy (Ti6Al4V-ELI), but they had different surface chemistries: sandblasted/acid-etched titanium surface (FN) or sandblasted/acid-etched surface maintained in an isotonic solution of 0.9% sodium chloride (FA). The surface morphology, topography and chemistry were evaluated by scanning electron microscopy (SEM), confocal microscopy (CM) and X-ray photoelectron spectroscopy (XPS), respectively. Dynamic contact angle (DCA) was employed for wettability evaluation. One implant from each group was placed in the left tibia of twenty healthy, skeletally mature Santa Ines sheep (n = 5). Bone area (BA) and bone-to-implant contact (BIC) were performed on thin sections (30 µm) at 7, 14, 21 and 28 days after implant installation. RESULTS: Despite the roughness and morphology similarities between the groups, at the XPS evaluation, the FA group presented 2.3 times less carbon on the surface (FN: 27.3% and FA: 11.6%), sharply enhanced hydrophilicity and significantly enhanced BA and BIC at 14, 21 and 28 days of healing (P < 0.05) compared with the FN. CONCLUSION: The data suggest that the hydrophilic FA accelerates the BA apposition and BIC interface around the implants during early stages of bone formation, providing highest degree of osseointegration.


Asunto(s)
Interfase Hueso-Implante/patología , Oseointegración , Tibia/cirugía , Titanio , Aleaciones , Animales , Implantación Dental Endoósea/métodos , Implantes Dentales , Interacciones Hidrofóbicas e Hidrofílicas , Microscopía Confocal , Microscopía Electrónica de Rastreo , Ovinos , Propiedades de Superficie , Tibia/patología
20.
Mater Sci Eng C Mater Biol Appl ; 60: 339-347, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26706539

RESUMEN

In this paper, the effects of cell geometry and relative density on the high-cycle fatigue behavior of Titanium scaffolds produced by selective laser melting and electron beam melting techniques were numerically investigated by finite element analysis. The regular titanium lattice samples with three different unit cell geometries, namely, diamond, rhombic dodecahedron and truncated cuboctahedron, and the relative density range of 0.1-0.3 were analyzed under uniaxial cyclic compressive loading. A failure event based algorithm was employed to simulate fatigue failure in the cellular material. Stress-life approach was used to model fatigue failure of both bulk (struts) and cellular material. The predicted fatigue life and the damage pattern of all three structures were found to be in good agreement with the experimental fatigue investigations published in the literature. The results also showed that the relationship between fatigue strength and cycles to failure obeyed the power law. The coefficient of power function was shown to depend on relative density, geometry and fatigue properties of the bulk material while the exponent was only dependent on the fatigue behavior of the bulk material. The results also indicated the failure surface at an angle of 45° to the loading direction.


Asunto(s)
Titanio/química , Materiales Biocompatibles/química , Análisis de Elementos Finitos , Ensayo de Materiales , Porosidad , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA