Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Artif Organs ; 27(1): 23-31, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36738330

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effect of decalcification and existence of stent at the aortic annulus on mitral annular motion after surgery. METHODS: Patients receiving Inspiris (Edwards, CA, USA, n = 117), Intuity (Edwards, n = 36), Perceval (Corcym, London, UK, n = 36), Evolut (Medtronics, MN, USA, n = 81) and Sapien 3 (Edwards, n = 250) were included in the study. Mitral annular motion was evaluated by E', using tissue doppler imaging. RESULTS: After surgery, a significant increase in E' was observed in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Discharge: 5.0 ± 1.23 cm/s, p < 0.001). Mid-term echocardiogram performed at 11.8 ± 2.2 months after the surgery, showed a significant increase in E' in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Mid-term: 5.2 ± 1.20 cm/s, p < 0.001) and Perceval (Before: 3.9 ± 1.34 cm/s vs. Mid-term: 4.5 ± 1.24 cm/s, p = 0.008). Univariable analysis showed a higher increase in E' in patients with decalcified annulus compared to those without decalcified annulus (Decalcification: 0.15 ± 1.321 cm/s vs. No Decalcification: 0.66 ± 1.420 cm/s, p < 0.001). Multivariable analysis showed that balloon-expandable stent (ß = - 0.6960, p < 0.001) and self-expanding stent (r = - 0.3592, p = 0.042) were independent limiting factors for an increase in E' at discharge. However, balloon-expandable stent (ß = - 0.8382, p < 0.001), and not self-expanding stent (ß = - 0.3682, p = 0.089), was a remaining independent factor associated with E' at mid-term follow-up. CONCLUSIONS: Decalcification was associated with improvement in E' after surgery. Balloon-expandable stent was an independent limiting factor for improvement in E' up to 1 year after the surgery, while self-expanding stent was not a significant factor after 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Stents , Resultado del Tratamiento , Diseño de Prótesis
3.
J Card Surg ; 37(9): 2706-2712, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726649

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the changes in mitral annular motion after surgery in patients with aortic stenosis. METHODS: Patients receiving Edwards (Edwards) valves were included in the study. Echocardiographic findings were compared among the three treatments postoperatively, at discharge, and at 1 year after the surgery. Mitral annular motion was evaluated by e prime, using tissue doppler imaging. RESULTS: There were 111 patients receiving Inspiris, 30 patients receiving Intuity and 241 patients receiving Sapien 3. The patients receiving Sapien 3 were significantly older, (Inspiris: 71 ± 6.7 years vs. Intuity: 75 ± 5.2 years vs. Sapien 3: 84 ± 5.1 years, p < .001), and prevalence of hemodialysis were significantly higher in patients receiving Intuity (Inspiris: 11.7% vs. Intuity: 46.7% vs. Sapien 3: 0.0%, p < .001). There was a significant improvement in mean pressure gradient in all groups (Inspiris: 55 ± 21.2-13 ± 5.2 mmHg, p < .001; Intuity: 48 ± 17.6-12 ± 4.9 mmHg, p < .001, Sapien 3: 55 ± 16.6-14 ± 5.2 mmHg, p < .001). Decalcification was associated with increase in e prime after surgery (no decalcification: 0.10 ± 1.280 cm/s vs. decalcification: 0.68 ± 1.405 cm/s, p < .001) Further, existence of stent was associated with less increase in e prime after surgery (no stent: 0.83 ± 1.210 cm/s vs. stent: 0.10 ± 1.356; p < .001). Multivariate analysis showed that existence of stent but not decalcification of the aortic valve was independently associated with changes in e prime after surgery (ß: -.4679, 95% confidence interval: -0.93389 to -0.00200, p = .049). CONCLUSIONS: Although improvement in pressure gradient was achieved in all treatments, existence of stent inhibited mitral annular motion after surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento
4.
Int J Cardiol Heart Vasc ; 9: 89-94, 2015 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-28785715

RESUMEN

BACKGROUND: Detection of concurrent diastolic dysfunction (DD) may be beneficial in patients with persistent and longstanding persistent atrial fibrillation (AF). The role of transthoracic echocardiography (TTE) in assessing DD in patients with AF has not been well characterized. We sought to determine the utility of TTE in detecting elevated left atrial pressure (LAP) in patients with persistent and longstanding persistent non-valvular AF using directly measured LAP as the reference standard. METHODS: We retrospectively studied 157 patients with persistent AF and preserved left ventricular ejection fraction who underwent pulmonary vein isolation (PVI). LAP was determined in conjunction with trans-septal puncture at the time of catheter ablation. TTE was performed 1 day after PVI and included two dimensional, pulse wave spectral Doppler and tissue Doppler assessments. RESULTS: The clinical parameter that strongly correlated with elevated LAP is longstanding persistent AF. Four strongest TTE parameters identified to moderately correlate with LAP include 1. left atrial minimum volume (LAVmin), 2. peak velocity of early mitral diastolic inflow velocity (E), 3. pulmonary vein systolic flow velocity (PVS), and 4. ratio of early diastolic transmitral inflow velocity to mitral annular velocity at the lateral site (E/E' lateral). CONCLUSION: Accurate assessment of diastolic dysfunction in patients with persistent and longstanding persistent AF is difficult using TTE. A combination of LAVmin, PVS, and E might be helpful to determine elevated LAP.

5.
J Cardiol ; 65(5): 397-402, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25062786

RESUMEN

BACKGROUND: Mitral annular motion (MAM) and tricuspid annular motion (TAM) velocities obtained by pulsed tissue Doppler echocardiography have been used to evaluate left ventricular (LV) and right ventricular (RV) functions. Although TAM velocity has been clinically applied for evaluating various cardiac diseases, the effects of age and gender remain unclear. Therefore, we aimed to determine the effects of age and gender on TAM velocity in normal hearts. METHODS: We randomly selected 265 subjects (mean age, 59 years; range, 20-89 years) without abnormal clinical, electrocardiographic, and echocardiographic findings from a pool of subjects who had undergone transthoracic echocardiography. They were classified into four age groups: 20-39, 40-59, 60-79, and >80 years. Pulsed wave Doppler was applied to obtain MAM velocity of the lateral side and TAM velocity of the RV free wall side. The peak systolic (s'), early diastolic (e'), and atrial systolic (a') velocities of MAM and TAM were measured in all subjects. RESULTS: While MAM-s' (r=-0.267, p<0.001) correlated with age, TAM-s' did not (p=0.755). TAM-s' in any age groups had no significant gender differences. TAM-e' (r=-0.447, p<0.001) and MAM-e' (r=-0.724, p<0.001) correlated with age, respectively. In those aged 40-59 years, both TAM-e' (p=0.002) and MAM-e' (p=0.048) in females were significantly higher than those in males. The gender differences diminished in the ≥60 years age groups. CONCLUSIONS: There was no age-associated decline in TAM-s', while TAM-e' varied with age and gender as did MAM-e'. Although the same criteria for the TAM-s' can be used for identifying abnormal RV systolic function regardless of age and gender, age and gender differences must be considered when one utilizes the TAM-e' for the diagnosis or management of cardiovascular disease.


Asunto(s)
Factores de Edad , Válvula Mitral/fisiología , Análisis de la Onda del Pulso , Factores Sexuales , Válvula Tricúspide/fisiología , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/diagnóstico , Diástole/fisiología , Ecocardiografía , Ecocardiografía Doppler , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Sístole/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA