EJNMMI Phys ; 11(1): 54, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951352

RESUMEN

BACKGROUND: Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI. MATERIALS AND METHODS: We implemented a standard measurement protocol, which applies a flow phantom in order to compare image-derived flow values with respect to a ground truth flow value with [15O]H2O MPI performed on both a Discovery MI (DMI-20, GE Healthcare) and a Biograph Vision 600 (Vision-600, Siemens Healthineers) system. Both systems have automatic [15O]H2O radio water generators (Hidex Oy) individually installed, allowing us to also study the differences occurring due to two different bolus delivery systems. To investigate the technical factors contributing to the modelled flow values, we extracted the [15O]H2O bolus profiles, the flow values from the kinetic modeling (Qin and Qout), and finally calculated their differences between test-retest measurements on both systems. RESULTS: The measurements performed on the DMI-20 system produced Qin and Qout values corresponging to each other as well as to the reference flow value across all test-retest measurements. The repeatability differences on DMI-20 were 2.1% ± 2.6% and 3.3% ± 4.1% for Qin and Qout, respectively. On Vision-600 they were 10% ± 8.4% and 11% ± 10% for Qin and Qout, respectively. The measurements performed on the Vision-600 system showed more variation between Qin and Qout values across test-retest measurements and exceeded 15% difference in 7/24 of the measurements. CONCLUSIONS: A preliminary protocol for measuring the accuracy and reproducibility of flow values in [15O]H2O MPI between digital PET/CT systems was assessed. The test-retest reproducibility falls below 15% in majority of the measurements conducted between two individual injector systems and two digital PET/CT systems. This study highlights the importance of implementing a standardized bolus injection and delivery protocol and importance of assessing technical factors affecting flow value reproducibility, which should be carefully investigated in a multi-center setting.

2.
Int J Womens Health ; 16: 1173-1186, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38952793

RESUMEN

Purpose: This study aimed to develop the Health Belief Model scale for premature birth prevention (HBM-PBP) and evaluated its psychometric properties in women of childbearing age. Methods: This study employed a cross-sectional design and included 724 women of childbearing age with intentions of future childbirth or in their first trimester of pregnancy. An item pool was formulated from the literature and in-depth interviews based on the health belief model. Content validation was conducted by experts and through cognitive interviews with women of childbearing age. Construct and concurrent validity and reliability were evaluated using factor analysis, Pearson's correlation analysis, and Cronbach's alpha. Results: The HBM-PBP consisted of 96 items, including perceived susceptibility (21 items, 5 subscales), severity (26 items, 5 subscales), benefits (27 items, 5 subscales), and barriers (22 items, 5 subscales). Convergent and discriminant validity were supported. The Cronbach's alpha coefficient of the domains ranged from 0.87 to 0.94. Conclusion: The HBM-PBP is a valid and reliable measurement scale with good psychometric properties. It can be used to measure health beliefs in women, either as a whole or in individual domains. Health professionals can leverage the HBM-PBP to discern women's health beliefs on premature birth, facilitating tailored interventions and educational efforts.

3.
Turk J Phys Med Rehabil ; 70(2): 164-170, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948641

RESUMEN

Objectives: This study aimed to quantify test-retest reliability and minimal detectable change (MDC) of the four commonly used functional tests in older adults with a high risk of falling. Patients and methods: The cross-sectional study was conducted with 30 community-dwelling older adults (26 females, 4 males; mean age: 73.7±6.0 years; range, 65 to 88 years) with a high fall risk identified by the Thai falls risk assessment test between November 2018 and May 2019. Data from the 10-m walk test at a comfortable gait speed (CGS) and fast gait speed (FGS), timed up and go (TUG) test, five times sit to stand test (FTSST), and 6-min walk test (6MWT) were collected twice for each participant. The interval between test sessions was one week. Test-retest reliability was analyzed by the intraclass correlation coefficient (ICC). Standard error of measurement (SEM) and MDC at the 95% confidence interval (MDC95) were also calculated. Results: The four functional tests had ICC in the range of 0.92 to 0.97. The SEM values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.06 m/sec, 0.04 m/sec, 1.10 sec, 1.30 sec, and 20.60 m, respectively. The MDC95 values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.16 m/sec, 0.12 m/sec, 3.00 sec, 3.50 sec, and 57.20 m, respectively. Conclusion: All functional tests demonstrated excellent test-retest reliability. The SEM and MDC95 of all functional tests were established. These findings can help clinicians interpret the effectiveness of interventions and determine changes in functional ability over time in older adults at high risk of falls.

4.
J Family Reprod Health ; 18(1): 44-52, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38863843

RESUMEN

Objective: Internalized transphobia (IT) is influenced by societal norms and expectations, and it can have significant negative effects on the well-being and mental health of transgender individuals. The aim of this study was to translate and evaluate the psychometric properties of the Persian 8-item IT scale among Iranian transgender individuals in order to enhance the quality and quantity of research in this field. Materials and methods: This cross-sectional and methodological study utilized convenience sampling to recruit 119 transgender individuals in Mashhad, the second most populous city in Iran, in 2021. The Persian translation of the IT scale was developed using the backward-forward translation method. Subsequently, various types of validity and reliability were assessed, including content validity using the content validity index (CVI) and content validity ratio (CVR), face validity based on the impact score, construct validity through confirmatory factor analysis (CFA), internal consistency measured by Cronbach's alpha, and test-retest stability analyzed using the intraclass correlation coefficient (ICC). Results: The CVR ranged from 0.600 to 1, the CVI ranged from 0.800 to 1, and the impact score exceeded 1.5, indicating the appropriate content and face validity of the 8-item IT scale. The construct validity analysis revealed that the questionnaire is one-dimensional. The internal consistency, as measured by Cronbach's alpha, was 0.917, and the ICC for test-retest stability was 0.871. Conclusion: The Persian version of the IT scale demonstrated high and acceptable psychometric properties. The brevity of this scale facilitates its dissemination and utilization in clinical settings.

5.
Eur Radiol Exp ; 8(1): 75, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38853182

RESUMEN

BACKGROUND: To study the reproducibility of 23Na magnetic resonance imaging (MRI) measurements from breast tissue in healthy volunteers. METHODS: Using a dual-tuned bilateral 23Na/1H breast coil at 3-T MRI, high-resolution 23Na MRI three-dimensional cones sequences were used to quantify total sodium concentration (TSC) and fluid-attenuated sodium concentration (FASC). B1-corrected TSC and FASC maps were created. Two readers manually measured mean, minimum and maximum TSC and mean FASC values using two sampling methods: large regions of interest (LROIs) and small regions of interest (SROIs) encompassing fibroglandular tissue (FGT) and the highest signal area at the level of the nipple, respectively. The reproducibility of the measurements and correlations between density, age and FGT apparent diffusion coefficient (ADC) values were evaluatedss. RESULTS: Nine healthy volunteers were included. The inter-reader reproducibility of TSC and FASC using SROIs and LROIs was excellent (intraclass coefficient range 0.945-0.979, p < 0.001), except for the minimum TSC LROI measurements (p = 0.369). The mean/minimum LROI TSC and mean LROI FASC values were lower than the respective SROI values (p < 0.001); the maximum LROI TSC values were higher than the SROI TSC values (p = 0.009). TSC correlated inversely with age but not with FGT ADCs. The mean and maximum FGT TSC and FASC values were higher in dense breasts in comparison to non-dense breasts (p < 0.020). CONCLUSIONS: The chosen sampling method and the selected descriptive value affect the measured TSC and FASC values, although the inter-reader reproducibility of the measurements is in general excellent. RELEVANCE STATEMENT: 23Na MRI at 3 T allows the quantification of TSC and FASC sodium concentrations. The sodium measurements should be obtained consistently in a uniform manner. KEY POINTS: • 23Na MRI allows the quantification of total and fluid-attenuated sodium concentrations (TSC/FASC). • Sampling method (large/small region of interest) affects the TSC and FASC values. • Dense breasts have higher TSC and FASC values than non-dense breasts. • The inter-reader reproducibility of TSC and FASC measurements was, in general, excellent. • The results suggest the importance of stratifying the sodium measurements protocol.


Asunto(s)
Mama , Imagen por Resonancia Magnética , Sodio , Humanos , Femenino , Reproducibilidad de los Resultados , Adulto , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Persona de Mediana Edad , Isótopos de Sodio , Voluntarios Sanos , Variaciones Dependientes del Observador , Adulto Joven
6.
Front Genet ; 15: 1407285, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38859936

RESUMEN

Introduction: HLA typing is a critical tool in both clinical and research applications at the individual and population levels. Benchmarking studies have indicated HLA-HD as the preferred tool for accurate and comprehensive HLA allele calling. The advent of next-generation sequencing (NGS) has revolutionized genetic analysis by providing high-throughput sequencing data. This study aims to evaluate, using the HLA-HD tool, the HLA typing content of whole exome, whole genome, and HLA-targeted panel sequence data from the consanguineous population of Arab ethnicity, which has been underrepresented in prior benchmarking studies. Methods: We utilized sequence data from family trios and individuals, sequenced on one or more of the whole exome, whole genome, and HLA-targeted panel sequencing technologies. The performance and resolution across various HLA genes were evaluated. We incorporated a comparative quality control analysis, assessing the results obtained from HLA-HD by comparing them with those from the HLA-Twin tool to authenticate the accuracy of the findings. Results: Our analysis found that alleles across 29 HLA loci can be successfully and consistently typed from NGS datasets. Clinical-grade whole exome sequencing datasets achieved the highest consistency rate at three-field resolution, followed by targeted HLA panel, research-grade whole exome, and whole genome datasets. Discussion: The study catalogues HLA typing consistency across NGS datasets for a large array of HLA genes and highlights assessments regarding the feasibility of utilizing available NGS datasets in HLA allele studies. These findings underscore the reliability of HLA-HD for HLA typing in underrepresented populations and demonstrate the utility of various NGS technologies in achieving accurate HLA allele calling.

7.
J Biomech ; 171: 112195, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38878344

RESUMEN

Movement biomarkers are crucial for assessing sensorimotor impairments and tracking the effects of interventions over time. The Uncontrolled Manifold (UCM) analysis has been proposed as a novel biomarker for evaluating movement stability and coordination in various motor tasks across neurological and musculoskeletal disorders. Through inter-trial analysis, the UCM partitions the variance of elemental variables (e.g., finger forces) into components that affect (VORT) and do not affect (VUCM) a performance variable (e.g., total force). A third index, ΔV, is computed as the normalized difference between VORT and VUCM. However, the minimum number of trials required to achieve stable UCM estimates, considering its clinimetric properties, is unknown. This study aimed to determine the minimal number (N) of trials for UCM estimates by computing bootstrap estimates of standard errors (SE) at different N trials using thresholds based on the minimal detectable change (MDC, i.e., the minimum change in an outcome measure beyond measurement error). Thirteen adults (24.6 ± 1.1 years old) performed a finger-pressing coordination task. We computed the 95 % confidence intervals (CI) of bootstrap SE distributions for each UCM estimate and detected the lowest number of trials with the 95 % CI of SE below each MDC threshold. We found the minimal N of trials required was VUCM = 14, VORT = 4 and ΔV = 18. Our findings highlight that a relatively low number of trials (i.e., N = 18) are sufficient to compute all UCM estimates beyond the MDC, supporting the use of the UCM framework in clinical settings where many repetitions of a motor task are not practical.

8.
Sensors (Basel) ; 24(11)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38894235

RESUMEN

This study investigated the reliability of measuring the median nerve cross-sectional area (CSA) at the carpal tunnel inlet using a handheld ultrasound device (HUD) compared to a standard ultrasound system, focusing on intra- and inter-operator reproducibility among novice and expert operators. Employing a prospective cross-sectional design, 37 asymptomatic adults were assessed using both devices, with measurements taken by an expert with over five years of experience and a novice with less than six months. The CSA was determined using manual tracing and ellipse methods, with reproducibility evaluated through intraclass correlation coefficients (ICCs) and agreement assessed via Bland-Altman plots. Results showed a high degree of agreement between the devices, with excellent intra-operator reproducibility (ICC > 0.80) for the expert, and moderate reproducibility for the novice (ICCs ranging from 0.539 to 0.841). Inter-operator reliability was generally moderate, indicating acceptable consistency across different experience levels. The study concludes that HUDs are comparable to standard ultrasound systems for assessing median nerve CSA in asymptomatic subjects, with both devices providing reliable measurements. This supports the use of HUDs in diverse clinical environments, particularly where access to traditional ultrasound is limited. Further research with a larger sample and symptomatic patients is recommended to validate these findings.


Asunto(s)
Nervio Mediano , Ultrasonografía , Humanos , Nervio Mediano/diagnóstico por imagen , Ultrasonografía/métodos , Masculino , Femenino , Adulto , Reproducibilidad de los Resultados , Estudios Transversales , Persona de Mediana Edad , Estudios Prospectivos , Síndrome del Túnel Carpiano/diagnóstico por imagen
9.
Sensors (Basel) ; 24(11)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38894359

RESUMEN

This study aimed to determine the absolute and relative reliability of concentric and eccentric flexion, extension, horizontal abduction, and adduction movements of the shoulder using a functional electromechanical dynamometer (FEMD). Forty-three active male university students (23.51 ± 4.72 years) were examined for concentric and eccentric strength of shoulder flexion, extension, horizontal abduction, and horizontal adduction with an isokinetic test at 0.80 m·s-1. Relative reliability was determined by intraclass correlation coefficients (ICCs) with 95% confidence intervals. Absolute reliability was quantified by the standard error of measurement (SEM) and coefficient of variation (CV). Reliability was very high to extremely high for all movements on concentric and eccentric strength measurements (ICC: 0.76-0.94, SEM: 0.63-6.57%, CV: 9.40-19.63%). The results of this study provide compelling evidence for the absolute and relative reliability of concentric and eccentric flexion, extension, horizontal abduction, and horizontal adduction shoulder isokinetic strength tests in asymptomatic adults. The mean concentric force was the most reliable strength value for all tests.


Asunto(s)
Fuerza Muscular , Hombro , Humanos , Masculino , Adulto , Fuerza Muscular/fisiología , Adulto Joven , Hombro/fisiología , Reproducibilidad de los Resultados , Rango del Movimiento Articular/fisiología , Dinamómetro de Fuerza Muscular , Articulación del Hombro/fisiología , Fenómenos Biomecánicos/fisiología , Músculo Esquelético/fisiología
10.
Biotechniques ; : 1-4, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899492

RESUMEN

Science is in the midst of a reproducibility crisis and the integration of artificial intelligence into scientific research has only compounded the problem; yet could the technology hold the solution to its own problems?[Formula: see text].

11.
J Med Libr Assoc ; 112(1): 42-47, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38911529

RESUMEN

Background: By defining search strategies and related database exports as code/scripts and data, librarians and information professionals can expand the mandate of research data management (RDM) infrastructure to include this work. This new initiative aimed to create a space in McGill University's institutional data repository for our librarians to deposit and share their search strategies for knowledge syntheses (KS). Case Presentation: The authors, a health sciences librarian and an RDM specialist, created a repository collection of librarian-authored knowledge synthesis (KS) searches in McGill University's Borealis Dataverse collection. We developed and hosted a half-day "Dataverse-a-thon" where we worked with a team of health sciences librarians to develop a standardized KS data management plan (DMP), search reporting documentation, Dataverse software training, and howto guidance for the repository. Conclusion: In addition to better documentation and tracking of KS searches at our institution, the KS Dataverse collection enables sharing of searches among colleagues with discoverable metadata fields for searching within deposited searches. While the initial creation of the DMP and documentation took about six hours, the subsequent deposit of search strategies into the institutional data repository requires minimal effort (e.g., 5-10 minutes on average per deposit). The Dataverse collection also empowers librarians to retain intellectual ownership over search strategies as valuable stand-alone research outputs and raise the visibility of their labor. Overall, institutional data repositories provide specific benefits in facilitating compliance both with PRISMA-S guidance and with RDM best practices.


Asunto(s)
Almacenamiento y Recuperación de la Información , Humanos , Almacenamiento y Recuperación de la Información/métodos , Difusión de la Información/métodos , Manejo de Datos/métodos , Bibliotecas Médicas/organización & administración , Bibliotecólogos/estadística & datos numéricos
12.
Am J Clin Pathol ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38913880

RESUMEN

OBJECTIVES: The benefits of liquid-based cytology (LBC) in routine cervical cancer screening are often associated with the availability of instrumented platforms and economic considerations. A low-cost alternative to LBC in low-volume settings remains an unmet need. METHODS: A multisite evaluation of the BD SurePath (SurePath) LBC Direct to Slide (DTS) method was conducted. The DTS preparations were evaluated across 3 sites. Cytology features for DTS preparation included predetermined thresholds for total cellularity, cell distribution, cellular preservation, and stain quality. Rare event detection was evaluated using SiHa cells spiked into pools from negative cytology specimens. Concordance between Bethesda classification results was evaluated for SurePath LBC and DTS methods using routinely collected SurePath specimens in a split-sample study design. RESULTS: The DTS specimens met criteria for total cellularity, cell distribution, cellular preservation, and stain quality in more than 98% of all cases. Rare event detection was observed with an average detection of 5 SiHa cells per 2 mL of specimen. Concordant cervical cytology classifications were observed between SurePath LBC and DTS methods. CONCLUSIONS: The results demonstrate that the DTS process is suitable for routine cervical cytology evaluation. The procedure is reproducible and detected abnormal cervical cells in concordance with standard SurePath LBC preparation.

13.
Forensic Sci Int Genet ; 72: 103088, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38908322

RESUMEN

Several fully continuous probabilistic genotyping software (PGS) use Markov chain Monte Carlo algorithms (MCMC) to assign weights to different proposed genotype combinations at a locus. Replicate interpretations of the same profile in these software are expected not to produce identical weights and likelihood ratio (LR) values due to the Monte Carlo aspect. This paper reports a detailed precision study under reproducibility conditions conducted as a collaborative exercise across the National Institute of Standards and Technology (NIST), Federal Bureau of Investigation (FBI), and Institute of Environmental Science and Research (ESR). Replicate interpretations generated across the three laboratories used the same input files, software version, and settings but different random number seed and different computers. This work demonstrates that using different computers to analyze replicate interpretations does not contribute to any variations in LR values. The study quantifies the magnitude of differences in the assigned LRs that is only due to run-to-run MCMC variability and addresses the potential explanations for the observed differences.

14.
Microbiol Spectr ; : e0033224, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916332

RESUMEN

Clinically validated human papillomavirus (HPV) assays are crucial in cervical cancer screening. In this study, we evaluated the Allplex HPV HR Detection assay (Seegene, SouthKorea) for its clinical accuracy and reproducibility according to the international criteria, using the RealTime High Risk HPV m2000 assay (Abbott, USA) as standard comparator. The Allplex HPV HR assay exhibits significant non-inferior sensitivity to detect cervical intraepithelial neoplasia grade (CIN) 2 or worse (CIN2+) with a ratio of 1.00 (95% CI: 0.97-1.03, P = 0.006), insignificant non-inferior sensitivity to detect CIN3+ with a ratio of 1.00 (95% CI: 0.88-1.13, P = 0.098), and non-inferior specificity to exclude CIN2+ with a ratio of 0.99 (95% CI: 0.99-1.00, P < 0.001) compared to the standard comparator. In addition, the assay shows an excellent reproducibility within the same laboratory [96.5% (95% CI: 94.6-97.9) with a kappa value of 0.91 (95% CI: 0.87-0.95)] and between laboratories [96.7% (95% CI: 94.8-98.0) with a kappa value of 0.91 (95% CI: 0.87-0.95)] for overall high-risk HPV positivity as well as for each individual HPV type. Pooling our study data with those of another independent study supports the consistency of our findings. We conclude that both the clinical accuracy to detect cervical precancer and the reproducibility of Allplex HPV HR Detection assay fulfill the international validation criteria of use in cervical cancer screening.IMPORTANCEThe clinical validation of human papillomavirus (HPV) assays in accordance with well-established international guidelines is crucial to ensure that only validated assays are used in the context of screening (Meijer et al., Int J Cancer, 2009). The guidelines, developed by an international consortium, require that a novel HPV assay has non-inferior accuracy against a standard comparator test for the detection of cervical intraepithelial neoplasia grade (CIN) 2 or worse (CIN2+). Additionally, a new HPV assay should meet specific criteria for both intra- and inter-laboratory reproducibility to ensure the assay consistently exhibits technical precision and robust performance. Pooling our study data with those of another independent study supports the consistency of our findings. In conclusion, both the clinical accuracy to detect cervical precancer and the reproducibility of Allplex HPV HR Detection assay fulfill the international validation criteria of use in cervical cancer screening.

15.
Appetite ; 200: 107568, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38901766

RESUMEN

Limited evidence is available about the variability of appetitive responses within individuals after an acute bout of exercise. The present study aimed to assess the consistency and individual variability of post-exercise appetitive responses in healthy individuals. Twenty participants (10 females, 23.9 ± 4.1 years, 22.5 ± 2.0 kg m-2) joined the laboratory to perform four sessions separated by a minimum of 5 days: i) a control session with a rest period before and an ad libitum lunch (REST), and ii) three identical exercise sessions (EX) with a 30-min moderate-intensity (60-70% of predicted maximal heart rate) walking bout ending 25 min before the ad libitum lunch. Subjective appetite sensations were assessed before and after the meal at regular intervals, and satiety quotients were calculated. Food reward was assessed by the Leeds Food Preference Questionnaire before and after lunch. For each EX session, the difference with the REST session was calculated (Δ = EX - REST). Energy and macronutrient intake were consistent in response to exercise (all intraclass correlation coefficients (ICC) > 0.8) while results showed that post-exercise subjective appetite sensations and satiety quotients varied across the three EX sessions (almost all ICC < 0.7). Food reward was overall consistent in response to exercise before the test meal but not after. When considering the changes (Δ), the results showed no or poor consistency for most of the appetitive outcomes. To conclude, energy and macronutrient intake, as well as pre-meal food reward, are consistent after exercise in healthy individuals, while subjective appetite sensations are not stable within individuals across the sessions. Regarding the variations from REST to EX sessions, the results suggest that the individual changes observed are only random day-to-day variations.

16.
Mol Imaging Biol ; 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38907124

RESUMEN

PURPOSE: Preclinical imaging, with translational potential, lacks a standardized method for defining volumes of interest (VOIs), impacting data reproducibility. The aim of this study was to determine the interobserver variability of VOI sizes and standard uptake values (SUVmean and SUVmax) of different organs using the same [18F]FDG-PET and PET/CT datasets analyzed by multiple observers. In addition, the effect of a standardized analysis approach was evaluated. PROCEDURES: In total, 12 observers (4 beginners and 8 experts) analyzed identical preclinical [18F]FDG-PET-only and PET/CT datasets according to their local default image analysis protocols for multiple organs. Furthermore, a standardized protocol was defined, including detailed information on the respective VOI size and position for multiple organs, and all observers reanalyzed the PET/CT datasets following this protocol. RESULTS: Without standardization, significant differences in the SUVmean and SUVmax were found among the observers. Coregistering CT images with PET images improved the comparability to a limited extent. The introduction of a standardized protocol that details the VOI size and position for multiple organs reduced interobserver variability and enhanced comparability. CONCLUSIONS: The protocol offered clear guidelines and was particularly beneficial for beginners, resulting in improved comparability of SUVmean and SUVmax values for various organs. The study suggested that incorporating an additional VOI template could further enhance the comparability of the findings in preclinical imaging analyses.

17.
Brain Behav Immun ; 120: 391-402, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38897330

RESUMEN

Rodent models of maternal immune activation (MIA) are increasingly used as experimental tools in preclinical research of immune-mediated neurodevelopmental disorders and mental illnesses. Using a viral-like MIA model that is based on prenatal poly(I:C) exposure in mice, we have recently identified the existence of subgroups of MIA-exposed offspring that show dissociable behavioral, transcriptional, brain network and inflammatory profiles even under conditions of genetic homogeneity and identical MIA. Here, we tested the hypothesis that the intrauterine positions of fetuses, which are known to shape individual variability in litter-bearing mammals through variations in fetal hormone exposure, may contribute to the variable outcomes of MIA in mice. MIA was induced by maternal administration of poly(I:C) on gestation day 12 in C57BL/6N mice. Determining intrauterine positions using delivery by Cesarean section (C-section), we found that MIA-exposed offspring developing between female fetuses only (0M-MIA offspring) displayed significant deficits in sociability and sensorimotor gating at adult age, whereas MIA-exposed offspring developing between one or two males in utero (1/2M-MIA offspring) did not show the same deficits. These intrauterine position effects similarly emerged in male and female offspring. Furthermore, while MIA elevated fetal brain levels of pro- and anti-inflammatory cytokines independently of the precise intrauterine position and sex of adjacent fetuses during the acute phase, fetal brain levels of TNF-α remained elevated in 0M-MIA but not 1/2M-MIA offspring until the post-acute phase in late gestation. As expected, 1/2M offspring generally showed higher testosterone levels in the fetal brain during late gestation as compared to 0M offspring, confirming the transfer of testosterone from male fetuses to adjacent male or female fetuses. Taken together, our findings identify a novel source of within-litter variability contributing to heterogeneous outcomes of short- and long-term effects in a mouse model of MIA. In broader context, our findings highlight that individual differences in fetal exposure to hormonal and inflammatory signals may be a perinatal factor that shapes risk and resilience to MIA.

18.
Nutrients ; 16(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38892498

RESUMEN

This study aimed to validate a semiquantitative electronic food frequency questionnaire (eFFQ) in estimating the intake of a comprehensive list of nutrients and bioactive compounds among adults from six regions of Argentina using multiple 24 h dietary recall (24HR) as a reference. A total of 163 adults completed two administrations of the eFFQ and four 24HRs. The paired t-test/Wilcoxon signed-rank test, Spearman/Pearson correlations, cross-classification, weighted kappa statistics, and Bland-Altman plots were employed to determine relative validity. To determine reproducibility, intraclass correlations (ICC), cross-classification, and weighted kappa statistics were calculated. For relative validity, crude correlations ranged from 0.15 to 0.57; energy adjustment and de-attenuation slightly improved most of these correlations. In cross-classification analysis, agreements within one quintile adjacent to exact agreement (EA ± 1) ranged from 52.2% to ~74%; extreme misclassifications were < 7%. For reproducibility, the crude ICC ranged from 0.29 to 0.85, showing moderate to good correlations for most nutrients. Cross-classification analysis showed agreement levels for the EA ± 1 quintile of 70.6% to 87.7%. Weighted kappa values ranged from 0.21 to 0.62. The results show that this eFFQ is relatively valid in ranking adults according to their nutrient intake and has an acceptable reproducibility, yet it slightly overestimates the intake of most nutrients.


Asunto(s)
Encuestas sobre Dietas , Humanos , Argentina , Adulto , Reproducibilidad de los Resultados , Femenino , Masculino , Persona de Mediana Edad , Encuestas sobre Dietas/normas , Encuestas sobre Dietas/métodos , Encuestas y Cuestionarios/normas , Dieta/estadística & datos numéricos , Adulto Joven , Registros de Dieta , Ingestión de Energía , Evaluación Nutricional , Conducta Alimentaria , Recuerdo Mental
19.
Anal Chim Acta ; 1312: 342767, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834270

RESUMEN

BACKGROUND: Surface-enhanced Raman spectroscopy (SERS) has gained increasing importance in molecular detection due to its high specificity and sensitivity. Complex biofluids (e.g., cell lysates and serums) typically contain large numbers of different bio-molecules with various concentrations, making it extremely challenging to be reliably and comprehensively characterized via conventional single SERS spectra due to uncontrollable electromagnetic hot spots and irregular molecular motions. The traditional approach of directly reading out the single SERS spectra or calculating the average of multiple spectra is less likely to take advantage of the full information of complex biofluid systems. RESULTS: Herein, we propose to construct a spectral set with unordered multiple SERS spectra as a novel representation strategy to characterize full molecular information of complex biofluids. This new SERS representation not only contains details from each single spectra but captures the temporal/spatial distribution characteristics. To address the ordering-independent property of traditional chemometric methods (e.g., the Euclidean distance and the Pearson correlation coefficient), we introduce Wasserstein distance (WD) to quantitatively and comprehensively assess the quality of spectral sets on biofluids. WD performs its superiority for the quantitative assessment of the spectral sets. Additionally, WD benefits from its independence of the ordering of spectra in a spectral set, which is undesirable for traditional chemometric methods. With experiments on cell lysates and human serums, we successfully achieve the verification for the reproducibility between parallel samples, the uniformity at different positions in the same sample, the repeatability from multiple tests at one location of the same sample, and the cardinality effect of the spectral set. SERS spectral sets also manage to distinguish different classes of human serums and achieve higher accuracy than the traditional prostate-specific antigen in prostate cancer classification. SIGNIFICANCE: The proposed SERS spectral set is a robust representation approach in accessing full information of biological samples compared to relying on a single or averaged spectra in terms of reproducibility, uniformity, repeatability, and cardinality effect. The application of WD further demonstrates the effectiveness and robustness of spectral sets in characterizing complex biofluid samples, which extends and consolidates the role of SERS.


Asunto(s)
Espectrometría Raman , Espectrometría Raman/métodos , Humanos , Propiedades de Superficie , Nanopartículas del Metal/química , Masculino
20.
Sci Rep ; 14(1): 12686, 2024 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-38830966

RESUMEN

Accurate, and objective diagnosis of brain injury remains challenging. This study evaluated useability and reliability of computerized eye-tracker assessments (CEAs) designed to assess oculomotor function, visual attention/processing, and selective attention in recent mild traumatic brain injury (mTBI), persistent post-concussion syndrome (PPCS), and controls. Tests included egocentric localisation, fixation-stability, smooth-pursuit, saccades, Stroop, and the vestibulo-ocular reflex (VOR). Thirty-five healthy adults performed the CEA battery twice to assess useability and test-retest reliability. In separate experiments, CEA data from 55 healthy, 20 mTBI, and 40 PPCS adults were used to train a machine learning model to categorize participants into control, mTBI, or PPCS classes. Intraclass correlation coefficients demonstrated moderate (ICC > .50) to excellent (ICC > .98) reliability (p < .05) and satisfactory CEA compliance. Machine learning modelling categorizing participants into groups of control, mTBI, and PPCS performed reasonably (balanced accuracy control: 0.83, mTBI: 0.66, and PPCS: 0.76, AUC-ROC: 0.82). Key outcomes were the VOR (gaze stability), fixation (vertical error), and pursuit (total error, vertical gain, and number of saccades). The CEA battery was reliable and able to differentiate healthy, mTBI, and PPCS patients reasonably well. While promising, the diagnostic model accuracy should be improved with a larger training dataset before use in clinical environments.


Asunto(s)
Conmoción Encefálica , Tecnología de Seguimiento Ocular , Aprendizaje Automático , Humanos , Adulto , Masculino , Femenino , Conmoción Encefálica/fisiopatología , Conmoción Encefálica/diagnóstico , Persona de Mediana Edad , Adulto Joven , Movimientos Oculares/fisiología , Reproducibilidad de los Resultados , Reflejo Vestibuloocular , Síndrome Posconmocional/diagnóstico , Síndrome Posconmocional/fisiopatología , Movimientos Sacádicos/fisiología , Atención/fisiología