Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.146
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Biomech Eng ; 147(1)2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39269637

RESUMEN

Elevation in left ventricular (LV) myocardial stiffness is a key remodeling-mediated change that underlies the development and progression of heart failure (HF). Despite the potential diagnostic value of quantifying this deterministic change, there is a lack of enabling techniques that can be readily incorporated into current clinical practice. To address this unmet clinical need, we propose a simple protocol for processing routine echocardiographic imaging data to provide an index of left ventricular myocardial stiffness, with protocol specification for patients at risk for heart failure with preserved ejection fraction. We demonstrate our protocol in both a preclinical and clinical setting, with representative findings that suggest sensitivity and translational feasibility of obtained estimates.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos , Humanos , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Fenómenos Mecánicos , Masculino , Fenómenos Biomecánicos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Función Ventricular Izquierda , Persona de Mediana Edad , Femenino , Anciano
2.
Ther Clin Risk Manag ; 20: 719-729, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39386226

RESUMEN

Background: Despite the efficacy of catheter ablation (CA) as a treatment for non-valvular atrial fibrillation (NVAF), many patients still experience atrial fibrillation (AF) recurrence after CA. This study aimed to evaluate the predictive value of speckle tracking echocardiographic (STE) parameters for AF recurrence post-ablation. Methods: A total of 380 NVAF patients treated with CA at the First Affiliated Hospital of Guangxi Medical University from January 2020 to March 2023 were prospectively recruited. The mean age was 59.4 ± 10.8 years, and 72.1% were male, including 150 patients (39.5%) with persistent AF and 230 patients (60.5%) with paroxysmal AF. STE was used to evaluate baseline left atrial (LA) function before CA within 48h. Over a median follow-up of 9 (interquartile range, 4-17) months, AF recurrence occurred in 132 patients (34.7%). Results: The recurrence group showed lower left ventricular ejection fraction, LA reservoir strain (LASr), and conduit strain (LAScd), but higher LA stiffness than non- recurrence group (all P < 0.05). Multivariable Cox regression identified LA stiffness and LASr as independent risk factors. Time-dependent ROC analysis showed that LA stiffness (AUC 0.768, 95% CI 0.705-0.831) and LASr (AUC 0.755, 95% CI 0.691-0.820) were better at predicting 1-year AF recurrence than other risk factors. For 2-year AF recurrence post-catheter ablation, LA stiffness (AUC 0.866, 95% CI 0.804-0.928) and LASr (AUC 0.860, 95% CI 0.800-0.920) also demonstrated superior predictive performance. Kaplan-Meier curves showed a significant difference in AF recurrence rate for patients with LA stiffness > 0.55 and LASr ≤ 24.3% (Log rank P < 0.01). Conclusion: Evaluation of LA function using STE assists in stratifying the risk of AF recurrence in NVAF patients and guiding follow-up management. LASr and LA stiffness are independent predictors of AF recurrence following CA in NVAF patients, and potentially outperforming other morphological parameters.

3.
Rev Cardiovasc Med ; 25(9): 324, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39355576

RESUMEN

Background: The left ventricular (LV) rotational mechanics are of particular importance in the function of the LV. The rotational movement is the consequence of the arrangement of the subepicardial and subendocardial muscle fibers. These muscle fibers are perpendicular to each other, their contraction creates a characteristic motion. The aim of the present study was to examine the prognostic impact of LV twist assessed by three-dimensional speckle-tracking echocardiography (3D-STE) in healthy circumstances. Methods: 302 healthy adults participated in the study, 181 subjects were excluded due to certain reasons (LV could not be analysed during 3D-STE, subjects were unidentifiable, or lost to follow-up). 121 subjects were involved in the final analysis (mean age of 33.1 ± 12.3 years, 75 males), who were willing to be examined on a voluntary basis. Results: During a mean follow-up of 7.93 ± 4.21 years, 11 healthy adults suffered a cardiovascular event including 2 cardiac deaths. Using receiver operating characteristic analysis, LV twist ≥14.65 degrees as assessed by 3D-STE proved to be significantly predictive regarding the cardiovascular event-free survival (area under the curve 0.70, specificity 70%, sensitivity 65%, p = 0.028). Subjects with LV twist ≥14.65 degrees had higher basal and apical rotations and a significantly higher ratio of these individuals developed cardiovascular events compared to cases with LV twist <14.65 degrees. Subjects with cardiovascular events had lower LV global longitudinal strain, higher basal LV rotation and twist and the ratio of subjects with LV twist ≥14.65 degrees was elevated as compared to cases without events. Conclusions: 3D-STE-derived LV twist independently predicts future cardiovascular events in healthy adults.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39368079

RESUMEN

AIM: We aimed to detect subclinical cardiac impairment in children with ulcerative colitis (UC) and test the association between absolute monocytic count (AMC) and lymphocyte-to-monocyte ratio (LMR) with disease activity. METHODS: A group of children with UC and a comparable group as healthy controls were included. All children underwent history-taking, clinical examination and blood testing for complete blood counts with white blood cell differentials, LMR and erythrocyte sedimentation rate (ESR). Disease severity was assessed using the Paediatric UC Activity Index score. We used echocardiography for tissue Doppler, M-Mode, two-dimensional and three-dimensional (3D) speckle tracking echocardiography (STE) for left ventricular function assessment. RESULTS: Forty children were included, 20 with UC as cases, and 20 healthy controls. Disease activity was mild in 75% cases and moderate in 25% cases. Cases had significantly higher ESR than the control group (P < 0.001). Among cases, positive correlations were observed between monocytic, and platelet counts with left ventricular end-diastolic diameter (r = 0.5, P = 0.02; r = 0.5, P = 0.03). Children with UC had significantly lower ejection fraction and impaired left ventricular systolic function compared to the control group (P < 0.001) assessed by 3D STE, yet this observation was not reached by the conventional method (P = 0.3). CONCLUSIONS: In children with UC, 3D STE could detect subclinical left ventricular systolic dysfunction that conventional echocardiography could not. AMC and LMR showed no significant difference between children with UC and controls.

5.
Pediatr Cardiol ; 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39365454

RESUMEN

Hematopoietic stem cell transplant (HSCT) is a potentially curative therapy for children with sickle cell disease (SCD). The effects of HSCT on ventricular function are not well characterized in children with SCD. Echocardiograms from children with SCD who underwent HSCT between 2007 and 2017 were retrospectively analyzed before and 1-year after HSCT. Left ventricular (LV) volumes, mass, and ejection fraction were calculated by the 5/6 area*length method. LV end-diastolic and systolic dimensions, septal, and posterior wall thickness, and fractional shortening were measured by M-mode. Mitral and tricuspid inflow Dopplers (E and A waves) as well as mitral, tricuspid, and septal tissue Dopplers (E', A') were assessed. E/A, E'/A' and E/E' ratios were calculated. Biventricular strain imaging was performed using speckle-tracking echocardiography. Peak global systolic longitudinal and circumferential LV strain, and global longitudinal right ventricular strain, as well as early and late diastolic strain rate, were measured on LV apical 4-chamber, LV short-axis mid-papillary, and RV apical views, respectively. Forty-seven children (9.7 ± 5.5 years, 60% male) met inclusion criteria. Pre-HSCT, subjects had mild LV dilation with normal LV systolic function by conventional measure of ejection fraction and fractional shortening. There was a significant reduction in LV volume, mass, and ejection fraction after HSCT, but measurements remained within normal range. LV longitudinal and circumferential strain were normal pre-HSCT and showed no significant change post-HSCT. RV strain decreased after HSCT, but the absolute change was small, and mean values were normal both pre- and post-HSCT. Conventional measures of diastolic function were all normal pre-HSCT. Post-HSCT there was a reduction in select parameters, but all parameters remained within normal range. Early and late diastolic strain rate parameters showed no significant change from pre- to post-HSCT. At one-year after HSCT in children with SCD conventional measures of systolic and diastolic function are within normal limits. Except for a small decrease in RV systolic strain with values remaining within normal limits, systolic strain and diastolic strain rate values did not significantly change 1-year after HSCT.

6.
Front Cardiovasc Med ; 11: 1460708, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39359643

RESUMEN

Lower extremity peripheral artery disease (PAD) is a growing global health problem. New methods to diagnose PAD have been explored in recent years. At present, the majority of imaging methods for PAD focus on the macrovascular blood flow, and the exploration of microcirculation and tissue perfusion of PAD remains largely insufficient. In this report, we applied three new imaging technologies, i.e., second near-infrared region (NIR-II, 900-1,880 nm wavelengths) imaging, optical coherence tomography angiography (OCTA), and laser speckle flowgraphy (LSFG), in a PAD patient with a healthy human subject as control. Our results showed that the PAD patient had poorer tissue perfusion than the control without observed adverse effects. Moreover, compared with the first near-infrared region (NIR-I, 700-900 nm wavelengths) imaging results, NIR-II imaging had a higher signal-to-background ratio and resolution than NIR-I imaging and detected microvessels that were not detected by NIR-I imaging. These observations suggested that NIR-II imaging, OCTA, and LSFG are potentially safe and effective methods for diagnosing PAD.

7.
Echocardiography ; 41(10): e15928, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39367766

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is strongly linked to the incidence and mortality of cardiovascular diseases (CVDs), with left ventricular myocardial damage being the most prevalent. This study aimed to assess left ventricle (LV) dysfunction using three-dimensional speckle tracking imaging (3D-STI) in CKD patients. METHODS: A total of 110 CKD patients and 55 healthy volunteers underwent echocardiography. CKD patients were divided into CKD1 group and CKD2 group based on the estimated glomerular filtration rate (eGFR). Assessing cardiac function via two-dimensional speckle tracking echocardiography (2D-STE) and three-dimensional speckle tracking echocardiography (3D-STE) parameters, with strain presented in absolute terms. Collecting and comparing clinical and echocardiographic parameters from three groups, assessing 3D-STI's value in evaluating LV functional impairment in CKD patients via correlation and receiver operating characteristic (ROC) curve analyses, and identifying risk factors for CKD progression to end-stage renal disease (ESRD) through univariate and multivariate analyses. RESULTS: In CKD2 group, 2D-left ventricular ejection fraction (LVEF), 3D-LVEF, 2D left ventricular global longitudinal strain (2D-LVGLS), 3D-LVGLS, and 3D-left ventricular global circumferential peak strain (LVGCS) significantly worsen compared to the control and CKD1 groups, with statistically significant distinctions between the latter two (all p < 0.05). The absolute value of 3D-LVGLS shows a robust correlation with N-terminal pro-B-type natriuretic peptide (NT-proBNP) and serum creatinine (Scr) (r = -0.598, -0.649, both p < 0.001). ROC curve analysis indicates higher diagnostic efficacy of 3D-LVGLS and 3D-LVGCS for LV systolic function than 2D-LVGLS. Univariate and multivariate analyses reveal an independent association of 3D-LVGLS with the progression to ESRD in CKD. CONCLUSION: 3D-LVGLS and 3D-LVGCS effectively detect LV dysfunction in CKD patients. Specifically, 3D-LVGLS demonstrates a robust correlation with NT-proBNP and Scr and is independently linked to CKD progressing to ESRD.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia Renal Crónica , Disfunción Ventricular Izquierda , Humanos , Masculino , Femenino , Ecocardiografía Tridimensional/métodos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/fisiopatología , Persona de Mediana Edad , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/complicaciones , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Adulto , Reproducibilidad de los Resultados
8.
J Clin Ultrasound ; 2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39392047

RESUMEN

OBJECTIVE: To evaluate the intra- and interobserver reproducibility of parameters used to determine cardiac morphometry and deformation using FetalHQ in Indian population. METHODOLOGY: Two operators blinded to each other performed FetalHQ analysis independently on 35 normal fetuses of gestational age between 18 + 0 and 37 + 0 weeks and days. Intra- and interobserver correlation coefficient and limits of agreement were ascertained for parameters obtained from HQ analysis. RESULTS: Excellent reproducibility (ICC > 0.9) was observed for global morphometric parameters. Ejection fraction, stroke volume, stroke volume/kg demonstrated excellent reliability (ICC > 0.9), cardiac output, fractional area change showed a lower correlation (ICC < 0.8), and right and left ventricular global strain showed no correlation. Twenty-four segment sphericity index of left ventricle (LV) and right ventricle (RV) showed low to moderate correlation (LV-ICC 0.48-0.79; RV-ICC 0.43-0.82). Fractional shortening (FS) showed poor intraobserver reliability in RV. CONCLUSION: FetalHQ provides reliable estimates of the global cardiac morphometry but not for global cardiac strain. Regional transverse contractility represented by FS has poor correlation in right ventricle, especially in the apical region, possibly due to moderator band. Nevertheless, it is a promising tool which requires technical advancements and validation to improve its accuracy and reliability.

9.
J Clin Anesth ; 99: 111646, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39383729

RESUMEN

BACKGROUND: Limited literature exists on the vascular reactivity of the radial and ulnar arteries in hypertensive patients following radial artery cannulation. This study assessed the vascular reactivity of the radial and ulnar arteries by comparing Doppler images and laser speckle contrast imaging (LSCI) obtained from both normotensive and hypertensive patients after radial artery cannulation under general anesthesia. METHODS: This study recruited 99 normotensive and 99 hypertensive patients who required arterial cannulation under general anesthesia. In the course of research, to evaluate the impact of hypertension on arterial reactivity, we employed duplex Doppler ultrasonography to measure the inner diameter (ID), resistance index (RI) and mean volume flow (MVF) of both arteries at five different time points. We equally performed perfusion of thumb and little finger by laser speckle contrast imaging. RESULTS: After radial artery cannulation, the hypertensive group showed less increase in radial ID and less decrease in RI compared to the normotensive group. The MVF increase was also less pronounced in hypertensive patients, while both groups demonstrated equivalent ulnar ID changes, and the normotensive group exhibited a more significant decrease in RI and a greater MVF increase. Thumb perfusion decreased post-cannulation in both groups, with the hypertensive group showing a less robust recovery. Little finger perfusion increased after artery cannulation in both groups, but the hypertensive group's increase was lower. The incidence of vasospasm in the hypertensive group is higher than that in the normotensive group. CONCLUSIONS: The radial and ulnar arteries in hypertensive patients may lack a compensatory response to radial artery cannulation during general anesthesia.

10.
Egypt Heart J ; 76(1): 136, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39377869

RESUMEN

BACKGROUND: Cryptogenic cerebrovascular stroke can be defined as an ischemic stroke that lacks a clear cause, even after a thorough evaluation. It should be distinguished from the embolic stroke of undetermined source (ESUS), a subgroup that includes cardio-embolic sources. This study aims to assess left atrial function through two-dimensional speckle tracking echocardiography (2D-STE) to determine its potential association with cryptogenic stroke and its predictive value for subclinical atrial fibrillation (AF). Our prospective cohort study involved 62 patients with unexplained cerebrovascular stroke or TIA, regardless of gender. Following TEE assessments, 22 patients were excluded due to identified sources of cardio-embolism. The remaining 40 participants were clustered into Group I. Group II, consisted of 40 healthy individuals without significant medical history, served as a control group. Both groups underwent two-dimensional trans-thoracic echocardiography and speckle tracking echocardiography. RESULTS: LA dysfunction parameters exhibited significant differences between Group I and Group II. LV diastolic dysfunction, LAVI, LAEF, and LASr were notably affected in Group I. At the same time, LA diameter in the parasternal long-axis view (PLAX) displayed a significant difference with a p value of 0.001. Within Group I, 14 patients experienced AF episodes (Group Ia, 35%); while, the remaining 26 were categorized as Group Ib (65%). LV diastolic dysfunction displayed a p value < 0.011; while, LAVI, LAEF, and LASr exhibited considerable differences with p values < 0.0001. However, the LA diameter showed no significant variation between the two groups. LASr emerged as the most sensitive and specific parameter for predicting AF, with a cutoff point of ≤ 24.5% and a p value < 0.0001. LAEF showed a cutoff point of ≤ 40.5% and a p value of 0.011. Meanwhile, LAVI demonstrated the lowest sensitivity and specificity, with a mean cutoff point of ≥ 38.5 ml/m2 and a p value of 0.003. CONCLUSIONS: 2D-STE is crucial for assessing LA dysfunction as a potential cryptogenic stroke cause after TEE and ruling out cardio-embolism sources. LASr serves as a key LA cardiopathy indicator, even preceding AF. LASr independently poses an AF risk. While LAEF and LAVI are significant LA dysfunction parameters and AF predictors, they exhibit lower sensitivity and specificity than LASr.

11.
Artículo en Inglés | MEDLINE | ID: mdl-39377164

RESUMEN

BACKGROUND: Coronavirus disease 2019 (COVID-19) was declared a global pandemic in 2019. It remains uncertain to what extent COVID-19 effects the heart in heathy individuals. To evaluate the effect of the COVID-19 on cardiac structure and function in middle-aged and older individuals. METHODS: A single-centre prospective observational study enroled a total of 124 participants (84 with history of COVID-19 [COVID-19 group] and 40 without a history of COVID-19 [non-COVID group]). All participants underwent echocardiography with speckle tracking to assess cardiac structure and function at rest and during peak exercise. RESULTS: There were no differences in left and right ventricular diastolic function (p ≥ 0.05) between the COVID-19 and non-COVID-19 groups. Participants in COVID-19 group demonstrated higher left ventricular mass (130 ± 39.8 vs. 113 ± 27.2 g, p = 0.008) and relative wall thickness (0.38 ± 0.07 vs. 0.36 ± 0.13, p = 0.049). Left ventricular global longitudinal strain was reduced in the COVID-19 group at rest and at peak-exercise (rest: 18.3 ± 2.01 vs. 19.3 ± 1.53%, p = 0.004; peak exercise: 19.1 ± 2.20 vs. 21.0 ± 1.58%, p ≤ 0.001). However, no difference was seen in resting left ventricular ejection fraction (58 ± 2.89 vs. 59 ± 2.51%, p = 0.565) between groups. Right ventricular fractional area change was reduced in the COVID-19 group (p = 0.012). CONCLUSION: Cardiac structural and functional remodelling was observed in middle-aged and older otherwise healthy individuals with a history of COVID-19.

12.
Eur Heart J Imaging Methods Pract ; 2(3): qyae091, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39391531

RESUMEN

Aims: Myocardial work (MW) is a relatively novel non-invasive echocardiographic method with increasing fields of application. Normal reference ranges of MW indices in patients who have undergone a heart transplant (HTx) have not been determined yet. The aim of this study was to obtain the reference ranges for 2D echocardiographic indices of MW for adult HTx patients and to compare them with the results of the European Association of Cardiovascular Imaging (EACVI) Normal Reference Ranges for Echocardiography (NORRE) study. Methods and results: All consecutive HTx patients admitted at our institution (University Hospital of Siena, Italy) between September 2019 and May 2022 who underwent endomyocardial biopsy (EMB) were considered. Patients with a history of rejection, a history of coronary artery vasculopathy, either acute cellular rejection or acute antibody-mediated rejection at EMB, and donor-specific antibodies were excluded. MW retrospectively performed for the included patients was retrieved, and the results were compared with those from the EACVI NORRE study. Out of 176 HTx patients who underwent EMB, 94 patients were excluded. The study population consisted of 82 HTx patients [68.3% male, median age 53 (46-62) years]. The median duration from HTx was 5 (2-22) months. The main MW indices such as global work efficiency (GWE, 84 ± 8%), global work index (GWI, 1447 ± 409 mmHg%), global constructive work (GCW, 2067 ± 423 mmHg%), and global wasted work [GWW, 310 (217-499) mmHg%] did not differ according to gender. Each of these indices significantly differed from those reported in the EACVI NORRE study (P-value <0.001), with lower GWI, GCW, and GWE and higher GWW values in the HTx population. Conclusion: This study provides reference ranges for MW indices in an adult HTx population free from transplant-related complications which proved to be different from those previously reported in healthy volunteers.

13.
Biomed Eng Lett ; 14(5): 1125-1135, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39220033

RESUMEN

Dual-mode optical imaging can simultaneously provide morphological and functional information. Furthermore, it can be integrated with projection mapping method to directly observe the images in the region of interest. This study was aimed to develop a dual-mode optical projection mapping system (DOPMS) that obtains laser speckle contrast image (LSCI) and subcutaneous vein image (SVI) and projects onto the region of interest, minimizing the spatial misalignment between the regions captured by the camera and projected by a projector. In in vitro and in vivo studies, LSCI and SVI were obtained and projected under single-mode illumination, where either the laser or light-emitting diode (LED) was activated, and under dual-mode illumination, where the laser and LED were activated simultaneously. In addition, fusion image (FI) of LSCI and SVI was implemented to selectively observe blood perfusion in the vein. DOPMS successfully obtained LSCI, SVI, and FI and projected them onto the identical region of interest, minimizing spatial misalignment. Single-mode illumination resulted in relatively clearer and noise-free images. Dual-mode illumination introduced speckle noise to SVI and FI but enabled real-time imaging by simultaneously employing LSCI, SVI, and FI. FI may be more effective for quasi-static evaluations before and after treatment under single-mode illumination and for real-time evaluation during treatment under dual-mode illumination owing to its faster image processing, albeit with a potential tradeoff in image quality.

14.
J Biophotonics ; : e202400184, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39246222

RESUMEN

Here we propose a not pupil-dependent microsaccades tracking technique and a novel detection method. We present a proof of concept for detecting microsaccades using a non-contact laser-based photonic system recording and processing the temporal changes of speckle patterns scattered from an eye sclera. The data, simultaneously recorded by the speckle-based tracker (SBT) and the video-based eye tracker (Eyelink), was analyzed by the frequently used detection method of Engbert and Kliegl (E&K) and by advanced machine learning detection (MLD) techniques. We detected 93% of microsaccades in the SBT data out of microsaccades detected in the Eyelink data with the E&K method. By utilizing MLD, a precision of 86% was achieved. The findings of our study demonstrate a potential improvement in measuring tiny eye movements, such as microsaccades, using speckle-based eye tracking and, thus, an alternative to video-based eye tracking for detecting microsaccades.

15.
Ultrasound Med Biol ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39244482

RESUMEN

OBJECTIVE: Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation. METHODS: High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V). 2-D blood-velocity profiles were obtained through native blood speckle tracking (BST) and contrast tracking (echo particle image velocimetry [echoPIV]). As a reference, 4-D flow magnetic resonance imaging (4-D flow MRI) was acquired. Contrast-to-background ratio and vector correlation were used to assess the quality of the US-VFI acquisitions. Spatiotemporal velocity profiles were extracted, from which peak velocities (PSV) were compared between the modalities. Furthermore, root-mean-square error analysis was performed. RESULTS: US-VFI was successful in 99% of the cases and optimal VFI quality was established with the 10V echoPIV and BST settings. A good correspondence between 10V echoPIV and BST was found, with a mean PSV difference of -0.5 cm/s (limits of agreement: -14.1-13.2). Both US-VFI techniques compared well with 4-D flow MRI, with a mean PSV difference of 1.4 cm/s (-18.7-21.6) between 10V echoPIV and MRI, and 0.3 cm/s (-23.8-24.4) between BST and MRI. Similar complex flow patterns among all modalities were observed. CONCLUSION: 2-D blood-flow quantification of femoral bifurcation is feasible with echoPIV and BST. Both modalities showed good agreement compared to 4-D flow MRI. For the femoral tract the administration of contrast was not needed to increase the echogenicity of the blood for optimal image quality.

16.
Neurophotonics ; 11(3): 035008, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39234576

RESUMEN

Significance: Cerebral hyperperfusion syndrome (CHS), characterized by neurologic deficits due to postoperative high cerebral perfusion, is a serious complication of superficial temporal artery-middle cerebral artery (STA-MCA) surgery for moyamoya disease (MMD). Aim: We aim to clarify the importance of assessing pre-anastomosis cerebral microcirculation levels by linking the onset of CHS to pre- and post-anastomosis hemodynamics. Approach: Intraoperative laser speckle contrast imaging (LSCI) measured changes in regional cerebral blood flow (rCBF) and regional blood flow structuring (rBFS) within the cerebral cortical microcirculation of 48 adults with MMD. Results: Following anastomosis, all MMD patients exhibited a significant increase in rCBF ( 279.60 % ± 120.00 % , p < 0.001 ). Changes in rCBF and rBFS showed a negative correlation with their respective baseline levels (rCBF, p < 0.001 ; rBFS, p = 0.005 ). Baseline rCBF differed significantly between CHS and non-CHS groups ( p = 0.0049 ). The areas under the receiver operating characteristic (ROC) curve for baseline rCBF was 0.753. Hemorrhagic MMD patients showed higher baseline rCBF than ischemic patients ( p = 0.036 ), with a marked correlation between pre- and post-anastomosis rCBF in hemorrhagic cases ( p = 0.003 ), whereas ischemic MMD patients did not. Conclusion: Patients with low levels of pre-anastomosis baseline CBF induce a dramatic increase in post-anastomosis and show a high risk of postoperative CHS.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39269417

RESUMEN

Myocardial strain imaging by echocardiography or cardiac magnetic resonance (CMR) is a powerful method to diagnose cardiac disease. Strain imaging provides measures of myocardial shortening, thickening, and lengthening and can be applied to any cardiac chamber. Left ventricular (LV) global longitudinal strain by speckle-tracking echocardiography is the most widely used clinical strain parameter. Several CMR-based modalities are available and are ready to be implemented clinically. Clinical applications of strain include global longitudinal strain as a more sensitive method than ejection fraction for diagnosing mild systolic dysfunction. This applies to patients suspected of having heart failure with normal LV ejection fraction, to early systolic dysfunction in valvular disease, and when monitoring myocardial function during cancer chemotherapy. Segmental LV strain maps provide diagnostic clues in specific cardiomyopathies, when evaluating LV dyssynchrony and ischemic dysfunction. Strain imaging is a promising modality to quantify right ventricular function. Left atrial strain may be used to evaluate LV diastolic function and filling pressure.

18.
Artículo en Inglés | MEDLINE | ID: mdl-39278576

RESUMEN

BACKGROUND: Right ventricular (RV) involvement has been reported in type 2 diabetes mellitus (T2DM). The relationship between glycemic control and RV function remains unknown. We aimed to investigate the association between glycemic control and RV function assessed by two-dimensional speckle-tracking echocardiography (2D-STE) and three-dimensional echocardiography (3DE) in T2DM individuals. METHODS: This study prospectively enrolled 207 patients with T2DM and 84 individuals with normal glucose metabolism (NGM). T2DM patients were divided into two subgroups according to glycated hemoglobin (HbA1c) level: controlled (HbA1c < 7.0%, n = 91) and uncontrolled subgroup (HbA1c ≥ 7.0%, n = 116). RV free wall longitudinal strain (RVFWLS) was acquired by 2D-STE, RV volumes and RV ejection fraction (RVEF) were assessed using 3DE. RV coupling to pulmonary circulation was defined as the ratio of RVFWLS/pulmonary artery systolic pressure (PASP). RESULTS: Controlled and uncontrolled T2DM subgroups had impaired RV function as reflected by reduced RVFWLS and RVEF compared to the NGM group. The reduction in RVFWLS was more pronounced in the uncontrolled subgroup than in the controlled subgroup (P < 0.001), whereas no significant difference was found in RVEF between these two T2DM subgroups. Higher PASP and lower RVFWLS/PASP ratio were also noted in uncontrolled T2DM patients. Additionally, the incidence of RV dysfunction was significantly higher in the uncontrolled T2DM patients than in the controlled subgroup (43.1% vs 17.6%, P < 0.001). After adjustment for potential clinical confounders, PASP and left ventricular parameters, HbA1c level was independently associated with RVFWLS (ß = 0.290, P = 0.003) and RVFWLS/PASP ratio (ß = 0.028, P = 0.006). CONCLUSIONS: Subclinical RV myocardial dysfunction is present in T2DM patients and is more pronounced in patients with uncontrolled blood glucose. HbA1c level is independently associated with subclinical RV myocardial dysfunction, providing further insight into a possible link between poor glycemic control and diabetic cardiomyopathy.

19.
Sensors (Basel) ; 24(17)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39275568

RESUMEN

Digital Image Correlation (DIC) often encounters challenges with variability and consistency in traditional speckle pattern application techniques, such as spray-painting, affecting measurement accuracy and reliability. This study evaluates a film-free water decal method as an alternative for applying speckle patterns in DIC. SS275 structural steel specimens were prepared with speckle patterns using both the film-free water decal method and traditional spray-painting. The quality of the speckle patterns was assessed, and their effectiveness for DIC was evaluated through tensile testing and a comparison with strain gauge measurements. The film-free water decal method provided enhanced control over speckle pattern application, resulting in high-quality, consistent patterns. Strain measurements obtained using this method closely matched those from traditional methods, confirming its reliability. The film-free water decal method offers a practical and reliable alternative to spray-painting, improving the consistency and accuracy of DIC experiments, with potential applications in various engineering and scientific fields.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA