Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Korean Med Sci ; 39(21): e178, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38832480

RESUMEN

BACKGROUND: Lessons learned from the Household Humidifier Disinfectant Tragedy (HHDT) in Korea, which poisoned thousands of citizens over a period of years, necessitated an examination of national poison prevention and surveillance systems. The objectives of this study are to identify essential changes needed in chemical poisoning prevention regulations and surveillance systems for effective poison control by comparing recent trends in international poison control center (PCC) operations, and to delineate the critical elements for establishing a state-of-the-art poison control surveillance system in Korea based on recent advances in PCCs with toxicovigilance. METHODS: A comprehensive review of Korea's regulatory and surveillance systems for chemical health hazards, with a focus on household products under the HHDT, was conducted. A review of toxicovigilance systems in major countries shows that creating an effective national PCC requires key elements: a centralized database of toxic substances and poisoning cases, mandatory or voluntary reporting of poisoning cases, real-time alerts, collaboration among health organizations, and targeted follow-up of poisoned individuals. RESULTS: Significant deficiencies in Korea's legislation, toxicological data management, and poisoning surveillance systems, explained the inadequate response of the Korean government to the HHDT for nearly 17 years until the end of 2011. Based on a review of PCC toxicovigilance systems in major countries, a national framework with five core components is recommended for establishing a modern comprehensive Korea PCC system with toxicovigilance capacity. The core components include establishment of a centralized database of toxic substances information and clinical poisoning cases, implementation of mandatory or permissive reporting of poisoning cases, real-time alert mechanisms, collaborative systems among health-related organizations, and clinical follow-up of poisoned sub-groups. CONCLUSION: A rationale and framework for a state-of-the-art national Korean PCC with toxicovigilance is justified and offered. This proposed system could assist neighboring countries in establishing their own sophisticated, globally integrated PCC networks.


Asunto(s)
Desinfectantes , Humidificadores , Intoxicación , Humanos , República de Corea/epidemiología , Desinfectantes/efectos adversos , Intoxicación/epidemiología , Intoxicación/prevención & control , Intoxicación/etiología , Centros de Control de Intoxicaciones
2.
Contact Dermatitis ; 91(2): 112-118, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38840483

RESUMEN

BACKGROUND: Mainly women work as foot care specialists (FCS). They are at risk to develop occupational dermatitis (OD). OBJECTIVES: The objective of this study is to describe the contact sensitisation pattern of female FCS with OD. METHODS: In a retrospective study, patch test and clinical data collected by the Network of Departments of Dermatology (IVDK) from 2008 to 2022 were analysed. Data of 116 female FCS with OD were compared with data of 13 930 female patients with OD working in other professions and 78 612 female patients without OD. RESULTS: Hand dermatitis (93.1%) was significantly more common and face dermatitis (0.9%) significantly less common in female FCS with OD compared to other female patients with or without OD. Frequent suspected allergen sources were disinfectants, gloves, leave-on and nail cosmetics. Occlusion and wetness were important co-factors. The most common diagnoses were irritant contact dermatitis (26.7%) and allergic contact dermatitis (21.6%). No sensitisation to any of the baseline series allergens was significantly more frequent in female FCS with OD than in the two control groups. However, sensitisations to allergens which FCS are abundantly exposed to, including fragrances, preservatives, rubber ingredients and disinfectants, were most common. CONCLUSIONS: FCS should be aware of the OD risk and prevention should be promoted.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Irritante , Dermatitis Profesional , Dermatosis de la Mano , Pruebas del Parche , Humanos , Femenino , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Dermatitis Profesional/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/diagnóstico , Estudios Retrospectivos , Adulto , Persona de Mediana Edad , Estudios de Casos y Controles , Dermatosis de la Mano/epidemiología , Dermatosis de la Mano/etiología , Dermatitis Irritante/epidemiología , Dermatitis Irritante/etiología , Alérgenos/efectos adversos , Dermatosis Facial/epidemiología , Dermatosis Facial/etiología , Cosméticos/efectos adversos , Desinfectantes/efectos adversos , Guantes Protectores/efectos adversos , Dermatosis del Pie/epidemiología
3.
Birth Defects Res ; 116(6): e2370, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38888449

RESUMEN

BACKGROUND: Associations between maternal periconceptional exposure to disinfection by-products (DBPs) in drinking water and neural tube defects (NTDs) in offspring are inconclusive, limited in part by exposure misclassification. METHODS: Maternal interview reports of drinking water sources and consumption from the National Birth Defects Prevention Study were linked with DBP concentrations in public water system monitoring data for case children with an NTD and control children delivered during 2000-2005. DBPs analyzed were total trihalomethanes, the five most common haloacetic acids combined, and individual species. Associations were estimated for all NTDs combined and selected subtypes (spina bifida, anencephaly) with maternal periconceptional exposure to DBPs in public water systems and with average daily periconceptional ingestion of DBPs accounting for individual-level consumption and filtration information. Mixed effects logistic regression models with maternal race/ethnicity and educational attainment at delivery as fixed effects and study site as a random intercept were applied. RESULTS: Overall, 111 case and 649 control children were eligible for analyses. Adjusted odds ratios for maternal exposure to DBPs in public water systems ranged from 0.8-1.5 for all NTDs combined, 0.6-2.0 for spina bifida, and 0.7-1.9 for anencephaly; respective ranges for average daily maternal ingestion of DBPs were 0.7-1.1, 0.5-1.5, and 0.6-1.8. Several positive estimates (≥1.2) were observed, but all confidence intervals included the null. CONCLUSIONS: Using community- and individual-level data from a large, US, population-based, case-control study, we observed statistically nonsignificant associations between maternal periconceptional exposure to total and individual DBP species in drinking water and NTDs and subtypes.


Asunto(s)
Desinfección , Agua Potable , Exposición Materna , Defectos del Tubo Neural , Humanos , Femenino , Agua Potable/efectos adversos , Defectos del Tubo Neural/etiología , Defectos del Tubo Neural/epidemiología , Embarazo , Exposición Materna/efectos adversos , Exposición Materna/estadística & datos numéricos , Desinfección/métodos , Adulto , Estudios de Casos y Controles , Desinfectantes/efectos adversos , Desinfectantes/análisis , Purificación del Agua/métodos , Trihalometanos/análisis , Trihalometanos/efectos adversos , Masculino , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/efectos adversos , Efectos Tardíos de la Exposición Prenatal , Disrafia Espinal/etiología , Disrafia Espinal/epidemiología
4.
Ann Work Expo Health ; 68(6): 593-604, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38697921

RESUMEN

OBJECTIVE: The main objective of this study was to comprehensively investigate the association between trichloramine (TCA) exposure and respiratory health effects in swimming pool workers. METHODOLOGY: In this study, air sampling was performed for TCA concentrations at fixed locations (static measurements) and on individual workers (personal measurements) in six indoor public swimming pools during periods of high swimmer attendance over the winter school break. Health effects were evaluated using questionnaires and fractional exhaled nitric oxide (FENO) tests performed before and after the working day. RESULTS: In these swimming pools, the environmental TCA concentration ranged from 0.11 to 0.88 mg/m³. Worker exposure ranged from 0.05 to 0.72 mg/m³ for personal measurements. Furthermore, in each swimming pool, the average worker exposure to TCA exceeded the recommended occupational exposure limit of 0.35 mg/m³. Personal TCA measurements were consistently lower than static measurements performed around the pool, with a reduction ranging from 21% to 49%. This can be explained by the time that the workers spend in the pool area, office, and break room. The most common respiratory health effects self-reported by the workers were coughing, shortness of breath, and sneezing with prevalence rates of 38%, 37%, and 35%, respectively. This study demonstrated an association between TCA exposure and eye irritation. Analysis of the FENO tests revealed that individuals with preexisting asthma or allergies exhibited sustained FENO elevation. CONCLUSION: The findings suggest that occupational exposure to TCA in indoor swimming pools is a matter of concern. Implementing and improving workplace safety measures is crucial for safeguarding the respiratory health of swimming pool workers.


Asunto(s)
Contaminación del Aire Interior , Compuestos de Nitrógeno , Exposición Profesional , Piscinas , Humanos , Exposición Profesional/análisis , Exposición Profesional/efectos adversos , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/estadística & datos numéricos , Adulto , Masculino , Compuestos de Nitrógeno/análisis , Compuestos de Nitrógeno/efectos adversos , Femenino , Óxido Nítrico/análisis , Persona de Mediana Edad , Contaminantes Ocupacionales del Aire/análisis , Encuestas y Cuestionarios , Monitoreo del Ambiente/métodos , Desinfectantes/análisis , Desinfectantes/efectos adversos , Adulto Joven , Cloruros
5.
Contact Dermatitis ; 91(1): 22-29, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38515234

RESUMEN

BACKGROUND: During the COVID-19 pandemic, increased hand hygiene practices were implemented. Impaired skin health on the hands among healthcare workers has been reported previously. Knowledge of how worker in other occupations have been affected is scarce. OBJECTIVES: To investigate self-reported hand water-, and soap exposure and use of hand disinfectants, and hand eczema (HE) in frontline workers outside the hospital setting and in IT personnel during the COVID-19 pandemic. METHODS: In this cross-sectional study, a questionnaire was sent out between 1 March and 30 April in 2021, to 6060 randomly selected individuals representing six occupational groups. RESULTS: A significant increase in water exposure and hand disinfectant use was shown: Relative position (RP) 19; 95% confidence interval (CI) 0.17-0.21 and RP = 0.38: 95% CI 0.36-0.41, respectively. Newly debuted HE was reported by 7.4% of the population, more frequently among frontline workers (8.6%) compared to IT personnel (4.9%). CONCLUSIONS: Water and soap exposure and use of hand disinfectants increased during COVID-19 pandemic, which may increase the risk of hand eczema. This highlights the importance of communication and implementation of preventive measures to protect the skin barrier also in occupations other than healthcare workers.


Asunto(s)
COVID-19 , Dermatitis Profesional , Eccema , Dermatosis de la Mano , Desinfección de las Manos , Autoinforme , Jabones , Humanos , COVID-19/prevención & control , COVID-19/epidemiología , Estudios Transversales , Jabones/efectos adversos , Masculino , Dermatosis de la Mano/epidemiología , Dermatosis de la Mano/etiología , Femenino , Adulto , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Eccema/epidemiología , Persona de Mediana Edad , Agua , Exposición Profesional/efectos adversos , Personal de Salud/estadística & datos numéricos , SARS-CoV-2 , Desinfectantes/efectos adversos , Encuestas y Cuestionarios , Higiene de las Manos
6.
J Allergy Clin Immunol Pract ; 12(8): 1974-1986, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38432401

RESUMEN

Exposure to disinfectants and cleaning products (DCPs) is now a well-established risk factor for work-related asthma (WRA). However, questions remain on the specific causal agents and pathophysiological mechanisms. Few studies have also reported an association between DCPs and rhinitis or chronic obstructive pulmonary disease. This review discusses the recent evidence pertaining to airway diseases attributable to occupational exposure to DCPs. In contrast to other agents, the incidence of WRA due to DCPs has increased over time. The use of DCPs in spray form has clearly been identified as an added risk factor. The mechanisms for WRA associated with DCPs remain poorly studied; however, both allergic and nonallergic responses have been described, with irritant mechanisms thought to play a major role. An early diagnostic workup based on clinical assessment accompanied by evaluation of lung function and immunological and airway inflammatory markers is important to guide optimal care and exposure avoidance to the implicated agent. Future research should focus on the effects of "green" products, pathophysiological mechanisms, and quantitative exposure assessment including the use of barcode-based methods to identify specific agents. There is an urgent need to strengthen preventive measures and interventions to reduce the burden of airway diseases associated with DCPs.


Asunto(s)
Detergentes , Exposición Profesional , Humanos , Exposición Profesional/efectos adversos , Detergentes/efectos adversos , Asma Ocupacional/diagnóstico , Desinfectantes/efectos adversos , Enfermedades Profesionales/diagnóstico
7.
Contact Dermatitis ; 90(5): 445-457, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38382085

RESUMEN

Frequent use of methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI in cosmetic products has been the main cause of widespread sensitization and allergic contact dermatitis to these preservatives (biocides). Their use in non-cosmetic products is also an important source of sensitization. Less is known about sensitization rates and use of benzisothiazolinone (BIT), octylisothiazolinone (OIT), and dichlorooctylisothiazolinone (DCOIT), which have never been permitted in cosmetic products in Europe. BIT and OIT have occasionally been routinely patch-tested. These preservatives are often used together in chemical products and articles. In this study, we review the occurrence of contact allergy to MI, BIT, OIT, and DCOIT over time, based on concomitant patch testing in large studies, and case reports. We review EU legislations, and we discuss the role of industry, regulators, and dermatology in prevention of sensitization and protection of health. The frequency of contact allergy to MI, BIT, and OIT has increased. The frequency of contact allergy to DCOIT is not known because it has seldom been patch-tested. Label information on isothiazolinones in chemical products and articles, irrespective of concentration, is required for assessment of relevance, information to patients, and avoidance of exposure and allergic contact dermatitis.


Asunto(s)
Cosméticos , Dermatitis Alérgica por Contacto , Desinfectantes , Tiazoles , Humanos , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/prevención & control , Cosméticos/efectos adversos , Desinfectantes/efectos adversos , Europa (Continente)/epidemiología , Conservadores Farmacéuticos/efectos adversos , Pruebas del Parche/efectos adversos
8.
Acta bioquím. clín. latinoam ; 56(4): 521-526, dic. 2022. graf
Artículo en Español | LILACS, BINACIS | ID: biblio-1439103

RESUMEN

Resumen Las amebas de vida libre (AVL) son protozoos ubicuos con cuatro géneros patógenos para el ser humano: Acanthamoeba, Naegleria, Balamuthia, y Sappinia. Acanthamoeba puede actuar como reservorio de microorganismos (endosimbiontes), por lo cual, en medio hospitalario, implicaría un riesgo para la transmisión de bacterias, virus y hongos intranosocomiales. Se investigó la presencia de AVL, con énfasis en Acanthamoeba spp., en un hospital pediátrico de la provincia de Buenos Aires, Argentina. Se colectaron 22 muestras de lavamanos e incubadoras en salas de Neonatología y Terapia Intensiva, las que fueron cultivadas a 37 y 42 °C. Los aislados fueron identificados molecularmente. El 63,64% de las muestras presentaron Acanthamoeba spp. Esta investigación representa el primer estudio realizado en la Argentina sobre la detección de Acanthamoeba spp. en salas cerradas de un hospital. Su presencia es una señal de alarma y resulta un blanco útil para investigar posibles reservorios de microorganismos patógenos en ambientes hospitalarios.


Abstract Free-living amoebae (FLA) are ubiquitous protozoa with four pathogenic genera for humans: Acanthamoeba, Naegleria, Balamuthia, and Sappinia. Acanthamoeba can act as a reservoir of microorganisms (endosymbionts), for which reason, in a hospital environment, it would imply a risk for transmission of nosocomial bacteria, viruses and fungi. The presence of AVL, with emphasis on Acanthamoeba spp., was investigated in a pediatric hospital. Twenty-two samples were collected from sinks and incubators in Neonatology and Intensive Care rooms, which were cultured at 37 and 42 °C. The isolates found were molecularly identified. A total of 63.64% of the samples presented Acanthamoeba spp. This research represents the first study in Argentina on the detection of Acanthamoeba spp. in closed rooms of a hospital. Its presence is an alarm signal, and it is a useful target to investigate possible reservoirs of pathogenic microorganisms in hospital environments.


Resumo As amebas de vida livre (AVL) são protozoários ubíquos com quatro gêneros patogênicos para o ser humano: Acanthamoeba, Naegleria, Balamuthia, e Sappinia. Acanthamoeba pode atuar como um reservatório de microrganismos (endossimbiontes), e portanto, em um ambiente hospitalar, representaria um risco de transmissão de bactérias, vírus e fungos intra-nosocomiais. A presença de AVL, com em Acanthamoeba spp. em um hospital pediátrico da província de Buenos Aires, Argentina, foi investigada. Vinte e duas amostras foram coletadas em lavatórios e incubadoras em Salas de Neonatologia e Cuidados Intensivos, cultivadas a 37 e 42 °C. Os isolados foram identificadas molecularmente. Foram encontradas Acanthamoeba spp. em 63,64% das amostras. Esta investigação representa o primeiro estudo realizado na Argentina sobre a detecção de Acanthamoeba spp. em salas fechadas de um hospital. A sua presença é um sinal de alarme e um alvo para investigar possíveis reservatórios de microrganismos patogênicos em ambientes hospitalares.


Asunto(s)
Amebiasis/parasitología , Desinfectantes/efectos adversos
9.
J. oral res. (Impresa) ; 11(5): 1-9, nov. 23, 2022. ilus
Artículo en Inglés | LILACS | ID: biblio-1435331

RESUMEN

Introduction: Chlorine, ethyl alcohol, and quaternary ammonium are disinfectants with antiviral activity against SARS-Cov2. However, there are no previous reports of their use and handling for cleaning and disinfection in dental offices. Objetive: To determine the use and management of disinfectants in critical and non-critical areas used by dentists in San Luis Potosí, Mexico, during the COVID-19 pandemic. Material and Methods: A validated cross-sectional survey was applied online to 100 dentists in San Luis Potosí between February and June 2021. Participants were informed about the handling of personal data according to the standard DOF regulations (DOF 07-05-2010). Results: A total of 100 dentists were included in the study, 63% female and 37% male, with a mean age of 26 years. The most widely used disinfectants during the pandemic in critical areas were Lysol® and 0.1% sodium hypochlorite in non-critical areas. Eighty-five percent of dentists know the adverse effects of inappropriate use of disinfectants, 72% did not have any sign or symptom associated with the use of disinfectants. The most used protection barrier was gloves (97%). Sixty-seven per cent of dentists disposed of disinfectant waste down the drain. Conclusion: Sodium hypochlorite and quaternary ammonium compounds and/or ethanol are used to clean non-critical and critical areas in dental offices. However, appropriate measures for their management are not adopted. It is necessary to implement educational strategies to improve the use and management of disinfectants in dental practice.


Introducción: Cloro, alcohol etílico y amonio cuaternario son desinfectantes que muestran actividad antiviral contra el SARS-Cov2, sin embargo, no existen reportes previos de su uso y manejo para la limpieza y desinfección en clínicas dentales. Objetivo: Determinar el uso y manejo de los desinfectantes en áreas críticas y no críticas empleados por los odontólogos en San Luis Potosí durante la COVID-19. Material y Métodos: Encuesta transversal validada y aplicada on-line a 100 odontólogos de San Luis Potosí durante febrero-junio 2021. Se informó a los participantes sobre el manejo de datos personales de acuerdo a la norma (DOF 05-07-2010). Resultados: Se incluyeron un total de 100 odontólogos, 63% del sexo femenino y 37% del sexo masculino, con una edad promedio de 26 años. Los desinfectantes más utilizados durante la pandemia en las áreas críticas fueron el Lysol® y el hipoclorito de sodio al 0.1% en áreas no críticas. El 85% de los odontólogos conocen los efectos adversos del uso inadecuado de los desinfectantes, 72% no tuvieron algún signo o síntoma asociado al uso de desinfectantes. La barrera de protección más utilizada fueron los guantes (97%). El 67% de los odontólogos eliminó los desechos de desinfectantes por la coladera. Conclusión: Para la limpieza de las áreas no críticas y críticas en las clínicas dentales se utilizan el hipoclorito de Sodio y compuestos de amonio cuaternario y/o etanol, sin embargo, no se utilizan las medidas adecuadas para su manejo. Es necesario implementar estrategias educativas para mejorar el uso y manejo de desinfectantes en la práctica dental.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Control de Infecciones/métodos , Odontólogos , Desinfectantes , Pandemias/prevención & control , COVID-19/prevención & control , Desinfección , Infección Hospitalaria/prevención & control , Estudios Transversales , Encuestas y Cuestionarios , Desinfectantes/efectos adversos , México/epidemiología
10.
Pesqui. vet. bras ; 33(11): 1319-1324, Nov. 2013. ilus, tab
Artículo en Inglés | LILACS | ID: lil-697877

RESUMEN

To verify the occurrence of caseous lymphadenitis in sheep and goats on farms of Pernambuco, Brazil, and in animals slaughtered in two Brazilian cities (Petrolina/PE and Juazeiro/BA), and to characterize the susceptibility profile of Corynebacterium pseudotuberculosis to disinfectants and antimicrobials, and its relationship with biofilm production were the objectives of this study. 398 samples were tested for sensitivity to antimicrobial drugs, disinfectants, and biofilm production. Among the 108 samples collected on the properties, 75% were positive for C. pseudotuberculosis. Slaughterhouse samples indicated an occurrence of caseous lymphadenitis in 15.66% and 6.31% for animals slaughtered in Petrolina and Juazeiro respectively. With respect to antimicrobials, the sensitivity obtained was 100% for florfenicol and tetracycline; 99.25% for enrofloxacin, ciprofloxacin and lincomycin; 98.99% for cephalothin; 98.74% for norfloxacin and sulfazotrim; 97.74% for gentamicin; 94.22% for ampicillin; 91.71% for amoxicillin; 91.21% for penicillin G; 89.19% for neomycin and 0% for novobiocin. In analyzes with disinfectants, the efficiency for chlorhexidine was 100%, 97.20% for quaternary ammonium, 87.40% for chlorine and 84.40% for iodine. 75% of the isolates were weak or non-biofilm producers. For the consolidated biofilm, found that iodine decreased biofilm formation in 13 isolates and quaternary ammonia in 11 isolates. The reduction of the biofilm formation was observed for iodine and quaternary ammonium in consolidated biofilm formation in 33% and 28% of the isolates, respectively. The results of this study highlight the importance of establishing measures to prevent and control the disease.


Verificar a ocorrência de linfadenite caseosa de ovinos e caprinos em fazendas de Pernambuco, no Brasil e em animais abatidos em duas cidades brasileiras (Petrolina/PE e Juazeiro/BA), caracterizar o perfil de suscetibilidade de Corynebacgerium pseudotuberculosis a desinfetantes e a antimicrobianos e analisar sua relação com a produção de biofilme foram os objetivos deste estudo. 398 amostras foram testadas para a sensibilidade aos medicamentos antimicrobianos, desinfetantes e produção de biofilme. Entre as 108 amostras coletadas nas propriedades, 75% foram positivas para C. pseudotuberculosis. Amostras do matadouro indicaram a ocorrência de linfadenite caseosa em 15,66% e 6,31% para animais abatidos em Petrolina (PE) e Juazeiro (BA), respectivamente. Com relação aos antimicrobianos, a sensibilidade obtida foi de 100% para florfenicol e tetraciclina, 99,25% para a enrofloxacina, ciprofloxacina e lincomicina; 98,99% para cefalotina; 98,74% para norfloxacina e sulfazotrim; 97,74% para gentamicina; 94,22% para ampicilina, 91,71% para amoxicilina, 91,21% para a penicilina G, 89,19% para a neomicina e 0% para novobiocina. Nas análises com desinfetantes, a eficiência para a clorexidina foi de 100%, 97,20% para amônia quaternária, 87,40% para o cloro e 84,40% para o iodo. 75% dos isolados foram fracos produtores de biofilme. Para o biofilme consolidado, observou-se que o iodo diminuiu a formação de biofilme em 13 isolados e a amônia quaternária em 11 isolados. A redução da formação de biofilme foi observada no biofilme consolidado, para iodo e amônia quaternária, em 33% e 28% das amostras, respectivamente. Os resultados deste estudo destacam a importância de se estabelecer medidas para prevenir e controlar a doença.


Asunto(s)
Animales , Biopelículas , Cabras/inmunología , Corynebacterium pseudotuberculosis/patogenicidad , Linfadenitis/veterinaria , Ovinos/inmunología , Antiinfecciosos/efectos adversos , Desinfectantes/efectos adversos
11.
Rev. Esc. Enferm. USP ; 47(2): 494-499, abr. 2013. tab
Artículo en Portugués | LILACS, BDENF | ID: lil-675983

RESUMEN

Materiais esterilizados em raios gama, ao serem re-esterilizados em óxido de etileno (EO), formam substâncias tóxicas? Esta questão norteou o objetivo deste estudo, que foi investigar o potencial efeito citotóxico do PVC esterilizado em radiação gama e re-esterilizado em EO pelo método da difusão em ágar em culturas celulares. Nove tubos de PVC foram submetidos à esterilização em radiação gama e re-esterilizados em EO. Os tubos foram divididos em um total de 81 unidades de análise, que foram testadas de forma a representar as superfícies internas, externas e massa de cada tubo. Concluiu-se que os materiais de PVC esterilizados em Radiação Gama e consecutivamente re-esterilizados em EO não são citotóxicos.


Do materials sterilized using gamma rays become toxic when re-sterilized in ethylene oxide? This question guided the objective of this study, which was to investigate the potential cytotoxic effect of PVC sterilized by gamma radiation and re-sterilized with EO by the agar diffusion method in cell cultures. Nine PVC tubes were subjected to gamma radiation sterilization and were re-sterilized in EO. The tubes were divided into a total of 81 units of analysis that were tested so as to represent the internal and external surfaces and mass of each tube. It was concluded that the PVC materials sterilized in gamma radiation and re-sterilized in EO are not cytotoxic.


Los materiales esterilizados con rayos gama, al ser re-esterilizados en óxido de etileno (EO), ¿forman substancias tóxicas? Esta pregunta orientó el objetivo del presente estudio, que fue investigar el potencial efecto citotóxico del PVC esterilizado en radiación gamma y re-esterilizado en EO por el método de difusión en agar en cultivos celulares. Nueve tubos de PVC fueron sometidos a esterilización por radiación gamma y re-esterilizados en EO. Se les aplicaron en total 81 unidades de análisis, las cuales fueron testeadas de manera tal de representar las superficies internas, externas y la masa de cada tubo. Se concluyó en que los materiales de PVC esterilizados con Radiación Gamma y, posteriormente, con EO, no son citotóxicos.


Asunto(s)
Citotoxinas/toxicidad , Desinfectantes/efectos adversos , Óxido de Etileno/efectos adversos , Rayos gamma , Cloruro de Polivinilo/efectos de la radiación , Cloruro de Polivinilo/toxicidad , Esterilización/métodos , Células Cultivadas
12.
Int. j. morphol ; 30(2): 521-523, jun. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-651823

RESUMEN

Formaldehyde inhalation, are known to be nasal mucosa irritating feature. This study we are examined the effects histopathologic of formaldehyde inhalation on rats by using light microscopy. 16 adult wistar albino rats were used in this study. 8 rats were in control group and 8 rats were in experiment group. Experiment group was exposed to 10 ppm formaldhyde 8hours/day,5days/week for 8 week. Nasal mucosa was removed and placed in 10 percent formaline. Sections were stained with Hematoxylene-Eosine and observed under light microscopy. The lining epithelium of respiratory mucosa showed a loss of ciliated cells with metaplasia of goblet cells and hyperplasia of squamous cells.


Es conocido que la inhalación de formaldehído tiene caraterísticas irritantes para la mucosa nasal. En este estudio se examinaron los efectos histopatológicos de la inhalación de formaldehído en ratas mediante microscopía de luz. Se utilizaron en este estudio 16 ratas Wistar albinas adultas, ocho ratas como grupo control y ocho como grupo experimental. El grupo experimental fue expuesto a 10 ppm formaldehído 8 horas/día, 5 días/semana por 8 semanas. La mucosa nasal fue retirada y colocada en formalina al 10 por ciento. Las secciones obtenidas fueron teñidas con Hematoxilina-Eosina y observadas al microscopio óptico. El epitelio de revestimiento de la mucosa respiratoria mostró una pérdida de células ciliadas con metaplasia de las células caliciformes e hiperplasia de células escamosas.


Asunto(s)
Animales , Ratas , Formaldehído/efectos adversos , Mucosa Respiratoria , Mucosa Respiratoria/patología , Administración por Inhalación , Desinfectantes/efectos adversos , Formaldehído/administración & dosificación , Microscopía , Mucosa Respiratoria/ultraestructura , Ratas Wistar
14.
Pesqui. vet. bras ; 29(1): 71-75, jan. 2009. graf
Artículo en Portugués | LILACS | ID: lil-509258

RESUMEN

Objetivou-se com este estudo avaliar a sensibilidade in vitro de Staphylococcus spp. frente a alguns desinfetantes comerciais utilizados no pré e pós-dipping em vacas leiteiras. Foram testados um total de 60 isoladosde Staphylococcus spp. identificados como S. aureus (50) e Staphylococcus coagulase positiva (10) recuperados deglândulas mamárias de vacas com mastite subclínica procedentes das regiões Metropolitana do Recife, Agreste e Zona da Mata do Estado de Pernambuco. O estudo da eficáciados desinfetantes utilizados no pré e pós-dipping foi realizado utilizando-se os seguintes princípios ativos: cloro(2,5%), iodo (0,57%), clorexidine (2,0%), amônia quaternária (4,0%) e ácido lático (2,0%) em quatro temposdistintos (15", 30", 60" e 300"). Observou-se que 100% de S. aureus foram sensíveis ao iodo, 93,3% sensíveis a clorexidine, 80% sensíveis a amônia, 35,6% sensíveis ao ácido lático e 97,8% resistentes ao cloro no tempo de 60". Com relação a Staphylococcus coagulase positiva (SCP), 100% dos isolados foram sensíveis ao iodo, 81,8% sensíveis a amônia quaternária, 99,9% sensíveis ao ácido lático, 72,7% sensíveis a clorexidine e 100% resistentes ao cloro no tempo de 60". Conclui-se que a maior atividade desinfetante in vitro foi verificada para o iodo e clorexidine frente a S. aureus e do iodo e ácido lático frente aos SCP e que há necessidade de avaliação periódica dos desinfetantes utilizadosnas propriedades leiteiras nas regiões estudadas, pois, existem variações no perfil de sensibilidade e resistênciaaos desinfetantes que podem comprometer os programas de controle da mastite bovina causada por Staphylococcusspp.


The objective of this investigation was to evaluate the in vitro sensibility ofStaphylococcus spp. to several commercially available disinfectants used for pre and post dipping. A total of 60 isolates of Staphylococcus spp., identified as Staphylococcus aureus (50) and Positive coagulase Staphylococcus (10) were obtained from the mammary glands of dairy cows with subclinical mastitis in the regions of Metropolitan Recife, the Agreste and the Zona da Mata of the State of Pernambuco, Brazil. As active ingredients were used a chlorine base (25%), iodine (0.6%), chlorhexidine (2.0%), quaternary ammonium (4.0%), and lactic acid (2.0%) at four specific intervals (15", 30", 60", and 300"). One hundred percent of S. aureus was found to be sensitive to iodine, 93.3% tochlorhexidine, 80% to ammonia, 35.6% to lactic acid, and 97.8% were resistant to chlorine at a 60-minute interval. With respect to the Positive coagulase Staphylococcus (SCP), 100.0% of the isolates were sensitive to iodine, 81.8% to quaternary ammonium, 99.9% to lactic acid, 72.7% to chlorhexidine, and 100% was resistant to chlorine at an interval of 60 minutes. It can be concluded that the highest disinfectant activity in vitro was found to be with iodine and chlorhexidine for S. aureus, and with iodine and lactic acid for SCP. Afurther conclusion was that it is important to undertake a periodic evaluation of the disinfectants used on the dairy properties in the regions studied, given the variety of sensibilities and resistance to disinfectants used, which may prejudice the control ofbovine mastitis caused by Staphylococcus spp.


Asunto(s)
Animales , Bovinos , Desinfectantes/efectos adversos , Mastitis Bovina/prevención & control , Staphylococcus/aislamiento & purificación
15.
J. bras. pneumol ; 33(4): 380-388, jul.-ago. 2007. ilus, tab
Artículo en Portugués | LILACS | ID: lil-466343

RESUMEN

OBJETIVO: Descrever a prevalência de sinais e sintomas de doença respiratória, avaliar as características do confinamento e identificar potenciais fatores de risco nos suinocultores do município de Braço do Norte, Santa Catarina. MÉTODOS: Um estudo do tipo observacional, de caráter exploratório, com delineamento transversal, em que a coleta de dados foi através de entrevistas e realização de espirometrias. Foram investigados o histórico laborativo, as condições do ambiente e trabalho, a saúde respiratória e o hábito tabágico. Como medida de risco foi utilizada a razão de chances da exposição, ao comparar suinocultores expostos e não expostos aos fatores de interesse de acordo com presença de sinais e sintomas de doença respiratória. RESULTADOS: A prevalência das manifestações de sintomas e sinais respiratórios foi de 84,3 por cento, de asma brônquica foi de 5,6 por cento e de bronquite crônica naqueles acima de 40 anos foi 5,1 por cento. Apenas 2,6 por cento dos suinocultores utilizavam equipamentos de proteção específica para o aparelho respiratório. Manifestações respiratórias entre os suinocultores mostraram-se associadas ao baixo nível socioeconômico, baixa escolaridade, tabagismo, uso de fogão a lenha e uso de desinfetantes. Havia uma aparente associação entre tempo e intensidade de trabalho e os achados de uma menor prevalência de manifestações respiratórias. CONCLUSÃO: O 'fenômeno saúde do trabalhador' pode explicar a associação entre tempo/intensidade de trabalho e a menor prevalência de manifestações respiratórias. Entretanto, o evidente comprometimento do aparelho respiratório entre os suinocultores e a baixa adoção de medidas de proteção específica nesta população apontam para a necessidade de um programa de controle da exposição e regulamentação dos fatores ambientais.


OBJECTIVE: To describe the prevalence of signs and symptoms of respiratory disease among pig farmers in Braço do Norte, Santa Catarina, Brazil, evaluating the characteristics of swine confinement buildings and identifying potential risk factors. METHODS: An exploratory, cross-sectional, observational study involving interviews and pulmonary function tests (spirometry). Aspects related to job history, work conditions, and environment, as well as to respiratory status and smoking, were evaluated. Odds ratios were used to estimate the chances of exposure when comparing pig farmers according to the signs and symptoms of respiratory disease. RESULTS: The prevalence of clinical signs and symptoms of respiratory disease was 84.3 percent, clinical manifestations of bronchial asthma were detected in 5.6 percent of the farmers evaluated, and chronic bronchitis was diagnosed in 5.1 percent of the workers over the age of 40. Only 2.6 percent used specific individual respiratory protection devices. Respiratory disease was positively associated with low socioeconomic level, low level of education, smoking, the use of wood stoves, and the use of disinfectants. Work load and length of employment were both apparently associated with a lower prevalence of respiratory disease. CONCLUSION: The association between duration of employment and lower prevalence of respiratory disease can be attributed to the healthy worker effect. However, the evident respiratory impairment among pig farmers and the limited use of personal protective equipment draw attention to the need to implement a program to monitor exposure and regulate environmental factors.


Asunto(s)
Adolescente , Adulto , Animales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades de los Trabajadores Agrícolas/epidemiología , Enfermedades Respiratorias/epidemiología , Enfermedades de los Trabajadores Agrícolas/etiología , Contaminación del Aire Interior/efectos adversos , Asma/epidemiología , Asma/etiología , Brasil/epidemiología , Bronquitis Crónica/epidemiología , Bronquitis Crónica/etiología , Culinaria , Desinfectantes/efectos adversos , Métodos Epidemiológicos , Exposición a Riesgos Ambientales/efectos adversos , Exposición Profesional/efectos adversos , Dispositivos de Protección Respiratoria , Enfermedades Respiratorias/etiología , Factores Socioeconómicos , Espirometría , Porcinos , Fumar/efectos adversos , Factores de Tiempo
16.
Rev. odonto ciênc ; 21(53): 261-265, jul.-set. 2006. ilus
Artículo en Inglés | LILACS, BBO | ID: lil-457367

RESUMEN

Introdução: Nas moldagens para obtenção de modelos para confecção de próteses, principalmente quando são realizadas em áreas retentivas da boca, resíduos de saliva e sangue ficam retidos no material e podem conter microoganismos patogênicos. Somente a lavagem do molde em água corrente não garante que todo sangue e microoganismos aderidos à superfície do molde tenham sido eliminados. Assim torna-se necessária a desinfecção dos moldes para a qual os métodos de desinfecção spray e imersão têm sido testados com várias soluções desinfetantes e provaram sua eficiência para esse propósito. No entanto, esse procedimento pode afetar a estabilidade dimensional do material de moldagem. Objetivo: Este estudo objetivou avaliar a estabilidade dimensional dos materiais de moldagem após a imersão em soluções desinfetantes de hipoclorito de sódio 1% e glutaraldeído 2%. Material e métodos: Foram realizadas 45 moldagens para cada um dos materiais: poliéter (Impregun F®), polissulfetos (Permlastic®), e hidrocolóide irreversível (Hydrogun®). 40 moldes de cada material foram imersos nas soluções desinfetantes variando-se o tempo entre 10 e 15 minutos. 10 moldes foram imersos em glutaraldeído a 2% por 10 min, 10 por 15 min, outras 10 imersos em hipoclorito de sódio a 1% por 10 min, e 10 por 15 min. Os demais moldes 5 não foram imersos em nenhum desinfetante e serviram como grupo controle. Resultados: Nos moldes obtidos foram medidas as distâncias (AB, CD, AC, BD) em um microscópio digital Mitutoyo (TM 500) e os resultados foram submetidos à análise de variância a 2 critérios e as diferenças pelo teste de Tukey com intervalo de confiança de 95%. A análise dos resultados mostrou que não houve diferenças estatísticas significantes para os moldes de poliéter e polissulfeto quando comparados ao grupo controle. No entanto, para os moldes de alginato desinfetados em hipoclorito de sódio a 1% por 15 min, observou-se uma distorção estatisticamente significante quando comparado ao grupo cont...


Asunto(s)
Desinfección/métodos , Desinfectantes/efectos adversos , Glutaral/administración & dosificación , Hipoclorito de Sodio/administración & dosificación , Materiales de Impresión Dental
18.
Rev. argent. coloproctología ; 16(4): 265-269, 2005. tab
Artículo en Español | LILACS | ID: lil-436571

RESUMEN

Introducción: La incidencia de complicaciones de la colonoscopía es del 0,1 al 3 por ciento y las más frecuentes son la perforación y la hemorragia. Las lesiones producidas por glutaraldehído al 2 por ciento son menos frecuentes y se deben a un efecto tóxico por acción directa sobre la mucosa del colon. Objetivo: analizar la proctitis por este desinfectante y analizar su presentación clínica. Diseño: Análisis retrospectivo. Revisión de la literatura. Pacientes: se registraron todas las colonoscopías (diagnósticas y terapéuticas), realizadas entre enero de 1996 y julio 2004. Métodos: se analizaron las complicaciones. Se realizó una actualización bibliográfica en bases nacionales e informáticas internacionales. Se evaluaron sexo y edad, tipo de endoscopía, sitio afectado, lesiones únicas o múltiples, presentación clínica y metodología diagnóstica, tiempo del diagnóstico, tipo de tratamiento y morbilidad asociada. El proceso de desinfección del instrumental se realizó según las normas establecidas por el servicio de infectología. Resultados: en un total de 4790 colonoscopías, se registraron 5 lesiones (0,1 por ciento) atribuidas al glutaraldehído. Fueron 2 pacientes del sexo masculino y 2 del sexo femenino. Una paciente tuvo dos episodios en dos colonoscopías. La edad promedio fue de 66 años. Todos fueron diagnosticados por la clínica. La presentación consistió en mucorrea, proctorragia leve, pujo y tenesmo. Ningún caso se presentó después de las 48 horas. El diagnóstico presuntivo fue confirmado por rectosigmoideoscopia con biopsia. Histología: rectitis inespecífica. El tratamiento fue sintomático y realizado en forma ambulatoria excepto un caso que requirió de internación por 24 horas. La resolución completa de los síntomas ocurrió antes de la primera semana. Discusión y conclusiones: la presentación de una colitis aguda, auto limitada luego de un procedimiento endoscópico normal con tenesmo y diarrea sanguinolenta en las 48 horas debe suponer este diagnóstico...


Asunto(s)
Humanos , Glutaral/efectos adversos , Glutaral/toxicidad , Proctitis/epidemiología , Proctitis/inducido químicamente , Proctitis/terapia , Colonoscopios , Colonografía Tomográfica Computarizada/efectos adversos , Colonoscopía/efectos adversos , Colonoscopía/métodos , Desinfectantes/efectos adversos , Peróxido de Hidrógeno/efectos adversos , Estudios Retrospectivos
19.
Rev. odontol. UNESP ; 25(1): 145-52, jan.-jun. 1996. tab
Artículo en Portugués | LILACS, BBO | ID: lil-192926

RESUMEN

Com a crescente preocupaçäo acerca da contaminaçäo microbiana cruzada, por meio de moldes e/ou modelos, é comum a imersäo dos moldes em soluçöes desinfetantes. O objetivo deste trabalho foi verificar até que ponto estas soluçöes afetariam a capacidade de umedecimento de alginatos por gessos tipo III. Foram utilizados dois alginatos, dois gessos tipo III e duas soluçöes desinfetantes. Os moldes obtidos, quando imersos nas soluçöes, permaneceram por 10, 20 ou 30 minutos; nos respectivos modelos de gesso, mediu-se o ângulo de contato. Quanto menor este ângulo melhor era considerada a adaptaçäo do gesso ao alginato. Verificou-se que houve uma variaçäo do ângulo de contato em razäo das marcas de alginatos, dos gessos e das soluçöes desinfetantes. Houve aumento do valor do ângulo de contato à medida que se aumentou o tempo de imersäo


Asunto(s)
Desinfectantes/administración & dosificación , Desinfectantes/análisis , Desinfectantes/efectos adversos , Alginatos , Modelos Dentales
20.
Rev. odontol. UNESP ; 24(2): 271-80, jul.-dez. 1995. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-187488

RESUMEN

A alteraçäo dimensional dos moldes de alginato decorrente do processo de desinfecçäo por imersäo foi avaliada para duas soluçöes desinfetantes, tendo como substância ativa o hipoclorito de sódio a 2,5 por cento (Q-boa) e 1 por cento (Soluçäo de Milton). Para avaliar essa alteraçäo foram confeccionados 35 corpos-de-prova de gesso pedra especial, obtidos a partir de moldes de alginatos imersos em soluçöes desinfetantes durante 5 e 10 minutos. Os resultados obtidos indicaram que o tempo de imersäo é importante e os moldes que permaneceram por 10 minutos nas soluçöes desinfetantes apresentaram alteraçöes na superfície dos modelos de gesso, apesar de as alteraçöes dimensionais serem clinicamente desprezíveis


Asunto(s)
Alginatos , Hipoclorito de Sodio/administración & dosificación , Hipoclorito de Sodio/efectos adversos , Glutaral/administración & dosificación , Glutaral/efectos adversos , Desinfectantes/administración & dosificación , Desinfectantes/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA