RESUMEN
Previous physiological and psychophysical studies have explored whether feedback to the cochlea from the efferent system influences forward masking. The present work proposes that the limited growth-of-masking (GOM) observed in auditory nerve (AN) fibers may have been misunderstood; namely, that this limitation may be due to the influence of anesthesia on the efferent system. Building on the premise that the unanesthetized AN may exhibit GOM similar to more central nuclei, the present computational modeling study demonstrates that feedback from the medial olivocochlear (MOC) efferents may contribute to GOM observed physiologically in onset-type neurons in both the cochlear nucleus and inferior colliculus (IC). Additionally, the computational model of MOC efferents used here generates a decrease in masking with longer masker-signal delays similar to that observed in IC physiology and in psychophysical studies. An advantage of this explanation over alternative physiological explanations (e.g., that forward masking requires inhibition from the superior paraolivary nucleus) is that this theory can explain forward masking observed in the brainstem, early in the ascending pathway. For explaining psychoacoustic results, one strength of this model is that it can account for the lack of elevation in thresholds observed when masker level is randomly varied from interval-to-interval, a result that is difficult to explain using the conventional temporal window model of psychophysical forward masking. Future directions for evaluating the efferent mechanism as a contributing mechanism for psychoacoustic results are discussed.
Asunto(s)
Cóclea , Enmascaramiento Perceptual , Humanos , Cóclea/fisiología , Enmascaramiento Perceptual/fisiología , Modelos Neurológicos , Vías Auditivas/fisiología , Vías Eferentes/fisiología , Simulación por Computador , Colículos Inferiores/fisiología , Estimulación Acústica , Nervio Coclear/fisiología , Percepción Auditiva/fisiología , Núcleo Coclear/fisiologíaRESUMEN
Novel stimulation methods are needed to overcome the limitations of contemporary cochlear implants. Optogenetics is a technique that confers light sensitivity to neurons via the genetic introduction of light-sensitive ion channels. By controlling neural activity with light, auditory neurons can be activated with higher spatial precision. Understanding the behaviour of opsins at high stimulation rates is an important step towards their translation. To elucidate this, we compared the temporal characteristics of auditory nerve and inferior colliculus responses to optogenetic, electrical, and combined optogenetic-electrical stimulation in virally transduced mice expressing one of two channelrhodopsins, ChR2-H134R or ChIEF, at stimulation rates up to 400 pulses per second (pps). At 100 pps, optogenetic responses in ChIEF mice demonstrated higher fidelity, less change in latency, and greater response stability compared to responses in ChR2-H134R mice, but not at higher rates. Combined stimulation improved the response characteristics in both cohorts at 400 pps, although there was no consistent facilitation of electrical responses. Despite these results, day-long stimulation (up to 13 h) led to severe and non-recoverable deterioration of the optogenetic responses. The results of this study have significant implications for the translation of optogenetic-only and combined stimulation techniques for hearing loss.
Asunto(s)
Vías Auditivas , Channelrhodopsins , Estimulación Eléctrica , Optogenética , Animales , Optogenética/métodos , Ratones , Vías Auditivas/fisiología , Vías Auditivas/metabolismo , Channelrhodopsins/metabolismo , Channelrhodopsins/genética , Estimulación Eléctrica/métodos , Colículos Inferiores/fisiología , Colículos Inferiores/metabolismo , Nervio Coclear/fisiología , Nervio Coclear/metabolismo , Cinética , Implantes CoclearesRESUMEN
This study investigated whether selective apical stimulation improves temporal pitch perception in eight MED-EL cochlear implant recipients and whether any such improvement relates to auditory-nerve survival. Three stimulation conditions differing in the place and width of excitation were evaluated: single-electrode stimulation of (i) the most apical, (ii) a mid-array electrode, and (iii) multi-electrode stimulation of the four most apical electrodes. Stimulation-current-induced non-stimulating electrode voltages were recorded to identify extracochlear electrodes and gauge insertion depth. The pitches of the four most apical electrodes were compared using place-pitch ranking. Rate-pitch ranking was assessed between 80 and 981 pulses per second for the three stimulation conditions, to estimate the "upper limit" of temporal pitch. Single-electrode apical stimulation did not increase the upper limit relative to other conditions. The polarity effect (PE), defined as the difference between thresholds obtained for triphasic pulse trains with their central high-amplitude phase either anodic or cathodic, was obtained to evaluate peripheral neural health. The PE did not differ between apical and mid-array stimulation or correlate with the upper limit. In conclusion, we found no improvement of temporal pitch perception with single-electrode apical stimulation, and discuss possible explanations for this observation.
Asunto(s)
Implantación Coclear , Implantes Cocleares , Estimulación Eléctrica , Percepción de la Altura Tonal , Humanos , Persona de Mediana Edad , Anciano , Implantación Coclear/instrumentación , Femenino , Masculino , Adulto , Estimulación Acústica/métodos , Nervio Coclear/fisiología , Nervio Coclear/fisiopatología , Umbral Auditivo , Factores de Tiempo , Personas con Deficiencia Auditiva/psicología , Personas con Deficiencia Auditiva/rehabilitaciónRESUMEN
The discovery and development of electrocochleography (ECochG) in animal models has been fundamental for its implementation in clinical audiology and neurotology. In our laboratory, the use of round-window ECochG recordings in chinchillas has allowed a better understanding of auditory efferent functioning. In previous works, we gave evidence of the corticofugal modulation of auditory-nerve and cochlear responses during visual attention and working memory. However, whether these cognitive top-down mechanisms to the most peripheral structures of the auditory pathway are also active during audiovisual crossmodal stimulation is unknown. Here, we introduce a new technique, wireless ECochG to record compound-action potentials of the auditory nerve (CAP), cochlear microphonics (CM), and round-window noise (RWN) in awake chinchillas during a paradigm of crossmodal (visual and auditory) stimulation. We compared ECochG data obtained from four awake chinchillas recorded with a wireless ECochG system with wired ECochG recordings from six anesthetized animals. Although ECochG experiments with the wireless system had a lower signal-to-noise ratio than wired recordings, their quality was sufficient to compare ECochG potentials in awake crossmodal conditions. We found non-significant differences in CAP and CM amplitudes in response to audiovisual stimulation compared to auditory stimulation alone (clicks and tones). On the other hand, spontaneous auditory-nerve activity (RWN) was modulated by visual crossmodal stimulation, suggesting that visual crossmodal simulation can modulate spontaneous but not evoked auditory-nerve activity. However, given the limited sample of 10 animals (4 wireless and 6 wired), these results should be interpreted cautiously. Future experiments are required to substantiate these conclusions. In addition, we introduce the use of wireless ECochG in animal models as a useful tool for translational research.
Asunto(s)
Estimulación Acústica , Audiometría de Respuesta Evocada , Vías Auditivas , Chinchilla , Nervio Coclear , Estimulación Luminosa , Vigilia , Tecnología Inalámbrica , Animales , Nervio Coclear/fisiología , Vigilia/fisiología , Tecnología Inalámbrica/instrumentación , Vías Auditivas/fisiología , Audiometría de Respuesta Evocada/métodos , Modelos Animales , Percepción Auditiva/fisiología , Cóclea/fisiología , Percepción Visual , Factores de TiempoRESUMEN
Cholinergic signaling is essential to mediate the auditory prepulse inhibition (PPI), an operational measure of sensorimotor gating, that refers to the reduction of the acoustic startle reflex (ASR) when a low-intensity, non-startling acoustic stimulus (the prepulse) is presented just before the onset of the acoustic startle stimulus. The cochlear root neurons (CRNs) are the first cells of the ASR circuit to receive cholinergic inputs from non-olivocochlear neurons of the ventral nucleus of the trapezoid body (VNTB) and subsequently decrease their neuronal activity in response to auditory prepulses. Yet, the contribution of the VNTB-CRNs pathway to the mediation of PPI has not been fully elucidated. In this study, we used the immunotoxin anti-choline acetyltransferase (ChAT)-saporin as well as electrolytic lesions of the medial olivocochlear bundle to selectively eliminate cholinergic VNTB neurons, and then assessed the ASR and PPI paradigms. Retrograde track-tracing experiments were conducted to precisely determine the site of lesioning VNTB neurons projecting to the CRNs. Additionally, the effects of VNTB lesions and the integrity of the auditory pathway were evaluated via auditory brain responses tests, ChAT- and FOS-immunohistochemistry. Consequently, we established three experimental groups: 1) intact control rats (non-lesioned), 2) rats with bilateral lesions of the olivocochlear bundle (OCB-lesioned), and 3) rats with bilateral immunolesions affecting both the olivocochlear bundle and the VNTB (OCB/VNTB-lesioned). All experimental groups underwent ASR and PPI tests at several interstimulus intervals before the lesion and 7, 14, and 21 days after it. Our results show that the ASR amplitude remained unaffected both before and after the lesion across all experimental groups, suggesting that the VNTB does not contribute to the ASR. The%PPI increased across the time points of evaluation in the control and OCB-lesioned groups but not in the OCB/VNTB-lesioned group. At the ISI of 50 ms, the OCB-lesioned group exhibited a significant increase in%PPI (p < 0.01), which did not occur in the OCB/VNTB-lesioned group. Therefore, the ablation of cholinergic non-olivocochlear neurons in the OCB/VNTB-lesioned group suggests that these neurons contribute to the mediation of auditory PPI at the 50 ms ISI through their cholinergic projections to CRNs. Our study strongly reinforces the notion that auditory PPI encompasses a complex mechanism of top-down cholinergic modulation, effectively attenuating the ASR across different interstimulus intervals within multiple pathways.
Asunto(s)
Estimulación Acústica , Vías Auditivas , Inhibición Prepulso , Reflejo de Sobresalto , Cuerpo Trapezoide , Animales , Inhibición Prepulso/fisiología , Masculino , Cuerpo Trapezoide/metabolismo , Cuerpo Trapezoide/fisiología , Vías Auditivas/fisiología , Vías Auditivas/metabolismo , Ratas Sprague-Dawley , Saporinas/metabolismo , Colina O-Acetiltransferasa/metabolismo , Neuronas Colinérgicas/metabolismo , Neuronas Colinérgicas/fisiología , Proteínas Inactivadoras de Ribosomas Tipo 1 , Potenciales Evocados Auditivos del Tronco Encefálico , Inmunotoxinas , Nervio Coclear/metabolismo , Nervio Coclear/fisiología , RatasRESUMEN
Objective. The cochlear implant (CI) belongs to the most successful neuro-prostheses. Traditionally, the stimulating electrode arrays are inserted into the scala tympani (ST), the lower cochlear cavity, which enables simple surgical access. However, often deep insertion is blocked, e.g. by ossification, and the auditory nerve fibers (ANFs) of lower frequency regions cannot be stimulated causing severe restrictions in speech understanding. As an alternative, the CI can be inserted into the scala vestibuli (SV), the other upper cochlear cavity.Approach. In this computational study, the excitability of 25 ANFs are compared for stimulation with ST and SV implants. We employed a 3-dimensional realistic human cochlear model with lateral wall electrodes based on aµ-CT dataset and manually traced fibers. A finite element approach in combination with a compartment model of a spiral ganglion cell was used to simulate monophasic stimulation with anodic (ANO) and cathodic (CAT) pulses of 50µs.Main results. ANO thresholds are lower in ST (mean/std =µ/σ= 189/55µA) stimulation compared to SV (µ/σ= 323/119µA) stimulation. Contrary, CAT thresholds are higher for the ST array (µ/σ= 165/42µA) compared to the SV array (µ/σ= 122/46µA). The threshold amplitude depends on the specific fiber-electrode spatial relationship, such as lateral distance from the cochlear axis, the angle between electrode and target ANF, and the curvature of the peripheral process. For CAT stimulation the SV electrodes show a higher selectivity leading to less cross-stimulation of additional fibers from different cochlear areas.Significance. We present a first simulation study with a human cochlear model that investigates an additional CI placement into the SV and its impact on the excitation behavior. Results predict comparable outcomes to ST electrodes which confirms that SV implantation might be an alternative for patients with a highly obstructed ST.
Asunto(s)
Implantación Coclear , Implantes Cocleares , Nervio Coclear , Rampa Timpánica , Escala Vestibular , Humanos , Nervio Coclear/fisiología , Rampa Timpánica/fisiología , Rampa Timpánica/cirugía , Escala Vestibular/fisiología , Implantación Coclear/métodos , Implantación Coclear/instrumentación , Electrodos Implantados , Estimulación Eléctrica/métodos , Estimulación Eléctrica/instrumentación , Cóclea/fisiología , Simulación por ComputadorRESUMEN
INTRODUCTION: The neural response telemetry (NRT) is a standard procedure in cochlear implantation mostly used to determine the functionality of implanted device and to check auditory nerve responds to the stimulus. Correlation between NRT measurements and subjective threshold (T) and maximum comfort (C) levels has been reported but results are inconsistent, and it is still not clear which of the NRT measurements could be the most useful in predicting fitting levels. PURPOSE: In our study we aimed to investigate which NRT measurement corresponds better to fitting levels. Impedance (IMP), Evoked Action Potential (ECAP) threshold and amplitude growth function (AGF) slope values were included in the study. Also, we tried to identify cochlear area at which the connection between NRT measurements and fitting levels would be the most pronounced. MATERIALS AND METHODS: Thirty-one children implanted with Cochlear device were included in this retrospective study. IMP, ECAP thresholds and AGF were obtained intra-operatively and 12 months after surgery at electrodes 5, 11 and 19 as representative for each part of cochlea. Subjective T and C levels were obtained 12 months after the surgery during cochlear fitting. RESULTS: ECAP thresholds obtained 12 months after surgery showed statistically significant correlation to both T and C levels at all 3 selected electrodes. IMP correlated with C levels while AGF showed tendency to correlate with T levels. However, these correlations were not statistically significant for all electrodes. CONCLUSION: ECAP threshold measurements correlated to T and C values better than AGF slope and IMP. Measurements obtained twelve months after surgery seems to be more predictive of T and C values compared to intra-operative measurements. The best correlation between ECAP threshold and T and C values was found at electrode 11 suggesting NRT measurements at mid-portion cochlear region to be the most useful in predicting fitting levels.
Asunto(s)
Umbral Auditivo , Implantación Coclear , Implantes Cocleares , Telemetría , Humanos , Implantación Coclear/métodos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Umbral Auditivo/fisiología , Nervio Coclear/fisiología , Potenciales Evocados Auditivos/fisiología , Ajuste de Prótesis/métodos , Cóclea/fisiología , LactanteRESUMEN
OBJECTIVE: In cochlear implant users with residual acoustic hearing, compound action potentials (CAPs) can be evoked by acoustic (aCAP) or electric (eCAP) stimulation and recorded through the electrodes of the implant. We propose a novel computational model to simulate aCAPs and eCAPs in humans, considering the interaction between combined electric-acoustic stimulation that occurs in the auditory nerve. METHODS: The model consists of three components: a 3D finite element method model of an implanted cochlea, a phenomenological single-neuron spiking model for electric-acoustic stimulation, and a physiological multi-compartment neuron model to simulate the individual nerve fiber contributions to the CAP. RESULTS: The CAP morphologies closely resembled those known from humans. The spread of excitation derived from eCAPs by varying the recording electrode along the cochlear implant electrode array was consistent with published human data. The predicted CAP amplitude growth functions largely resembled human data, with deviations in absolute CAP amplitudes for acoustic stimulation. The model reproduced the suppression of eCAPs by simultaneously presented acoustic tone bursts for different masker frequencies and probe stimulation electrodes. CONCLUSION: The proposed model can simulate CAP responses to electric, acoustic, or combined electric-acoustic stimulation. It considers the dependence on stimulation and recording sites in the cochlea, as well as the interaction between electric and acoustic stimulation in the auditory nerve. SIGNIFICANCE: The model enhances comprehension of CAPs and peripheral electric-acoustic interaction. It can be used in the future to investigate objective methods, such as hearing threshold assessment or estimation of neural health through aCAPs or eCAPs.
Asunto(s)
Potenciales de Acción , Implantes Cocleares , Simulación por Computador , Estimulación Eléctrica , Potenciales Evocados Auditivos , Humanos , Potenciales Evocados Auditivos/fisiología , Potenciales de Acción/fisiología , Estimulación Eléctrica/métodos , Nervio Coclear/fisiología , Estimulación Acústica/métodos , Modelos Neurológicos , Cóclea/fisiología , Análisis de Elementos FinitosRESUMEN
To enable nervous system function, neurons are powered in a use-dependent manner by mitochondria undergoing morphological-functional adaptation. In a well-studied model system-the mammalian cochlea, auditory nerve fibers (ANFs) display distinct electrophysiological properties, which is essential for collectively sampling acoustic information of a large dynamic range. How exactly the associated mitochondrial networks are deployed in functionally differentiated ANFs remains scarcely interrogated. Here, we leverage volume electron microscopy and machine-learning-assisted image analysis to phenotype mitochondrial morphology and distribution along ANFs of full-length in the mouse cochlea inner spiral bundle. This reveals greater variance in mitochondrial size with increased ANF habenula to terminal path length. Particularly, we analyzed the ANF terminal-residing mitochondria, which are critical for local calcium uptake during sustained afferent activities. Our results suggest that terminal-specific enrichment of mitochondria, in addition to terminal size and overall mitochondrial abundance of the ANF, correlates with heterogenous mitochondrial contents of the terminal.
Asunto(s)
Nervio Coclear , Mitocondrias , Animales , Mitocondrias/ultraestructura , Ratones , Nervio Coclear/ultraestructura , Nervio Coclear/fisiología , Microscopía Electrónica , Fibras Nerviosas/ultraestructura , Masculino , Ratones Endogámicos C57BLRESUMEN
The encoding of acoustic stimuli requires precise neuron timing. Auditory neurons in the cochlear nucleus (CN) and brainstem are well suited for accurate analysis of fast acoustic signals, given their physiological specializations of fast membrane time constants, fast axonal conduction, and reliable synaptic transmission. The medial olivocochlear (MOC) neurons that provide efferent inhibition of the cochlea reside in the ventral brainstem and participate in these fast neural circuits. However, their modulation of cochlear function occurs over time scales of a slower nature. This suggests the presence of mechanisms that reduce MOC inhibition of cochlear function. To determine how monaural excitatory and inhibitory synaptic inputs integrate to affect the timing of MOC neuron activity, we developed a novel in vitro slice preparation ("wedge-slice"). The wedge-slice maintains the ascending auditory nerve root, the entire CN and projecting axons, while preserving the ability to perform visually guided patch-clamp electrophysiology recordings from genetically identified MOC neurons. The "in vivo-like" timing of the wedge-slice demonstrates that the inhibitory pathway accelerates relative to the excitatory pathway when the ascending circuit is intact, and the CN portion of the inhibitory circuit is precise enough to compensate for reduced precision in later synapses. When combined with machine learning PSC analysis and computational modeling, we demonstrate a larger suppression of MOC neuron activity when the inhibition occurs with in vivo-like timing. This delay of MOC activity may ensure that the MOC system is only engaged by sustained background sounds, preventing a maladaptive hypersuppression of cochlear activity.
Asunto(s)
Vías Auditivas , Núcleo Coclear , Inhibición Neural , Neuronas Eferentes , Animales , Ratones , Núcleo Coclear/fisiología , Núcleo Coclear/citología , Inhibición Neural/fisiología , Neuronas Eferentes/fisiología , Neuronas Eferentes/efectos de los fármacos , Vías Auditivas/fisiología , Femenino , Masculino , Nervio Coclear/fisiología , Técnicas de Placa-ClampRESUMEN
This study introduces and evaluates the PHAST+ model, part of a computational framework designed to simulate the behavior of auditory nerve fibers in response to the electrical stimulation from a cochlear implant. PHAST+ incorporates a highly efficient method for calculating accommodation and adaptation, making it particularly suited for simulations over extended stimulus durations. The proposed method uses a leaky integrator inspired by classic biophysical nerve models. Through evaluation against single-fiber animal data, our findings demonstrate the model's effectiveness across various stimuli, including short pulse trains with variable amplitudes and rates. Notably, the PHAST+ model performs better than its predecessor, PHAST (a phenomenological model by van Gendt et al.), particularly in simulations of prolonged neural responses. While PHAST+ is optimized primarily on spike rate decay, it shows good behavior on several other neural measures, such as vector strength and degree of adaptation. The future implications of this research are promising. PHAST+ drastically reduces the computational burden to allow the real-time simulation of neural behavior over extended periods, opening the door to future simulations of psychophysical experiments and multi-electrode stimuli for evaluating novel speech-coding strategies for cochlear implants.
Asunto(s)
Potenciales de Acción , Adaptación Fisiológica , Implantes Cocleares , Nervio Coclear , Simulación por Computador , Estimulación Eléctrica , Modelos Neurológicos , Nervio Coclear/fisiología , Animales , Humanos , Factores de Tiempo , Implantación Coclear/instrumentación , Biofisica , Estimulación AcústicaRESUMEN
The auditory brainstem response (ABR) is a valuable clinical tool for objective hearing assessment, which is conventionally detected by averaging neural responses to thousands of short stimuli. Progressing beyond these unnatural stimuli, brainstem responses to continuous speech presented via earphones have been recently detected using linear temporal response functions (TRFs). Here, we extend earlier studies by measuring subcortical responses to continuous speech presented in the sound-field, and assess the amount of data needed to estimate brainstem TRFs. Electroencephalography (EEG) was recorded from 24 normal hearing participants while they listened to clicks and stories presented via earphones and loudspeakers. Subcortical TRFs were computed after accounting for non-linear processing in the auditory periphery by either stimulus rectification or an auditory nerve model. Our results demonstrated that subcortical responses to continuous speech could be reliably measured in the sound-field. TRFs estimated using auditory nerve models outperformed simple rectification, and 16â minutes of data was sufficient for the TRFs of all participants to show clear wave V peaks for both earphones and sound-field stimuli. Subcortical TRFs to continuous speech were highly consistent in both earphone and sound-field conditions, and with click ABRs. However, sound-field TRFs required slightly more data (16â minutes) to achieve clear wave V peaks compared to earphone TRFs (12â minutes), possibly due to effects of room acoustics. By investigating subcortical responses to sound-field speech stimuli, this study lays the groundwork for bringing objective hearing assessment closer to real-life conditions, which may lead to improved hearing evaluations and smart hearing technologies.
Asunto(s)
Estimulación Acústica , Electroencefalografía , Potenciales Evocados Auditivos del Tronco Encefálico , Percepción del Habla , Humanos , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Masculino , Femenino , Percepción del Habla/fisiología , Estimulación Acústica/métodos , Adulto , Adulto Joven , Umbral Auditivo/fisiología , Factores de Tiempo , Nervio Coclear/fisiología , Voluntarios SanosRESUMEN
OBJECTIVES: Electrocochleography (ECochG) appears to offer the most accurate prediction of post-cochlear implant hearing outcomes. This may be related to its capacity to interrogate the health of underlying cochlear tissue. The four major components of ECochG (cochlear microphonic [CM], summating potential [SP], compound action potential [CAP], and auditory nerve neurophonic [ANN]) are generated by different cochlear tissue components. Analyzing characteristics of these components can reveal the state of hair and neural cell in a cochlea. There is limited evidence on the characteristics of intracochlear (IC) ECochG recordings measured across the array postinsertion but compared with extracochlear recordings has better signal to noise ratio and spatial specificity. The present study aimed to examine the relationship between ECochG components recorded from an IC approach and postoperative speech perception or audiometric thresholds. DESIGN: In 113 human subjects, responses to 500 Hz tone bursts were recorded at 11 IC electrodes across a 22-electrode cochlear implant array immediately following insertion. Responses to condensation and rarefaction stimuli were then subtracted from one another to emphasize the CM and added to one another to emphasize the SP, ANN, and CAP. Maximum amplitudes and extracochlear electrode locations were recorded for each of these ECochG components. These were added stepwise to a multi-factor generalized additive model to develop a best-fit model predictive model for pure-tone audiometric thresholds (PTA) and speech perception scores (speech recognition threshold [SRT] and consonant-vowel-consonant phoneme [CVC-P]) at 3- and 12-month postoperative timepoints. This best-fit model was tested against a generalized additive model using clinical factors alone (preoperative score, age, and gender) as a null model proxy. RESULTS: ECochG-factor models were superior to clinical factor models in predicting postoperative PTA, CVC-P, and SRT outcomes at both timepoints. Clinical factor models explained a moderate amount of PTA variance ( r2 = 45.9% at 3-month, 31.8% at 12-month, both p < 0.001) and smaller variances of CVC-P and SRT ( r2 range = 6 to 13.7%, p = 0.008 to 0.113). Age was not a significant predictive factor. ECochG models explained more variance at the 12-month timepoint ( r2 for PTA = 52.9%, CVC-P = 39.6%, SRT = 36.4%) compared with the 3-month one timepoint ( r2 for PTA = 49.4%, CVC-P = 26.5%, SRT = 22.3%). The ECochG model was based on three factors: maximum SP deflection amplitude, and electrode position of CM and SP peaks. Adding neural (ANN and/or CAP) factors to the model did not improve variance explanation. Large negative SP deflection was associated with poorer outcomes and a large positive SP deflection with better postoperative outcomes. Mid-array peaks of SP and CM were both associated with poorer outcomes. CONCLUSIONS: Postinsertion IC-ECochG recordings across the array can explain a moderate amount of postoperative speech perception and audiometric thresholds. Maximum SP deflection and its location across the array appear to have a significant predictive value which may reflect the underlying state of cochlear health.
Asunto(s)
Audiometría de Respuesta Evocada , Umbral Auditivo , Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Percepción del Habla/fisiología , Persona de Mediana Edad , Femenino , Masculino , Anciano , Adulto , Adulto Joven , Cóclea , Periodo Posoperatorio , Anciano de 80 o más Años , Adolescente , Potenciales Microfónicos de la Cóclea/fisiología , Nervio Coclear/fisiopatología , Nervio Coclear/fisiología , Niño , Sordera/rehabilitación , Sordera/fisiopatologíaRESUMEN
This dataset was collected to study the functional consequences of age-related hearing loss for the auditory nerve, which carries acoustic information from the periphery to the central auditory system. Using high-impedance glass electrodes, raw voltage traces and spike times were recorded from more than one thousand single fibres of the auditory nerve of young-adult, middle-aged, and old Mongolian gerbils raised in a quiet environment. The dataset contains not only responses to simple acoustic stimuli to characterize the fibres, but also to more complex stimuli, such as speech logatomes in background noise and Schroeder-phase stimuli. A software toolbox is provided to search through the dataset, to plot various analysed outcomes, and to give insight into the analyses. This dataset may serve as a valuable resource to test further hypotheses about age-related hearing loss. Additionally, it can aid in optimizing available computational models of the auditory system, which can contribute to, or eventually even fully replace, animal experiments.
Asunto(s)
Envejecimiento , Nervio Coclear , Gerbillinae , Animales , Gerbillinae/fisiología , Nervio Coclear/fisiología , Estimulación AcústicaRESUMEN
INTRODUCTION: The functional evaluation of auditory-nerve activity in spontaneous conditions has remained elusive in humans. In animals, the frequency analysis of the round-window electrical noise recorded by means of electrocochleography yields a frequency peak at around 900 to 1000 Hz, which has been proposed to reflect auditory-nerve spontaneous activity. Here, we studied the spectral components of the electrical noise obtained from cochlear implant electrocochleography in humans. METHODS: We recruited adult cochlear implant recipients from the Clinical Hospital of the Universidad de Chile, between the years 2021 and 2022. We used the AIM System from Advanced Bionics® to obtain single trial electrocochleography signals from the most apical electrode in cochlear implant users. We performed a protocol to study spontaneous activity and auditory responses to 0.5 and 2 kHz tones. RESULTS: Twenty subjects including 12 females, with a mean age of 57.9 ± 12.6 years (range between 36 and 78 years) were recruited. The electrical noise of the single trial cochlear implant electrocochleography signal yielded a reliable peak at 3.1 kHz in 55% of the cases (11 out of 20 subjects), while an oscillatory pattern that masked the spectrum was observed in seven cases. In the other two cases, the single-trial noise was not classifiable. Auditory stimulation at 0.5 kHz and 2.0 kHz did not change the amplitude of the 3.1 kHz frequency peak. CONCLUSION: We found two main types of noise patterns in the frequency analysis of the single-trial noise from cochlear implant electrocochleography, including a peak at 3.1 kHz that might reflect auditory-nerve spontaneous activity, while the oscillatory pattern probably corresponds to an artifact.
Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Estimulación Acústica/métodos , Audiometría de Respuesta Evocada/métodos , Nervio Coclear/fisiología , Ruido , MasculinoRESUMEN
INTRODUCTION: Electrically evoked compound action potentials (ECAPs) are used for intra-/postoperative monitoring with intracochlear stimulation of cochlear implants. ECAPs are recorded in MED-EL (Innsbruck, Austria) implants using auditory response telemetry (ART), which has been further developed with automatic threshold determination as AutoART. The success of an ECAP measurement also depends on the number of available spiral ganglion cells and the bipolar neurons of the cochlear nerve (CN). It is assumed that a higher population of spiral ganglion cell implies a larger CN cross-sectional area (CSA), which consequently affects ECAP measurements. METHODS: Intraoperative ECAP measurements from 19 implanted ears of children aged 8 to 18 months were retrospectively evaluated. A comparison and correlation of ART/AutoART ECAP thresholds/slopes at electrodes E2 (apical), E6 (medial), E10 (basal), and averaged E1 to E12 with CN CSA on magnetic resonance imaging was performed. RESULTS: A Pearson correlation of the ART/AutoART ECAP thresholds/slopes for E2/E6/E10 and the averaged electrodes E1 to E12 showed a significant correlation. The CN CSA did not correlate significantly with the averaged ART/AutoART ECAP thresholds/slopes across all 12 electrodes. SUMMARY: AutoART provides reliable measurements and is therefore a suitable alternative to ART. No significant influence of CN CSA on ECAP thresholds/slopes was observed. A predictive evaluation of the success of ECAP measurements based on CN CSA for a clinical setting cannot be made according to the present data.
Asunto(s)
Implantación Coclear , Implantes Cocleares , Niño , Lactante , Humanos , Preescolar , Estudios Retrospectivos , Potenciales Evocados Auditivos/fisiología , Implantación Coclear/métodos , Nervio Coclear/fisiología , Potenciales de Acción/fisiología , Estimulación EléctricaRESUMEN
Data from non-human primates can help extend observations from non-primate species to humans. Here we report measurements on the auditory nerve of macaque monkeys in the context of a controversial topic important to human hearing. A range of techniques have been used to examine the claim, which is not generally accepted, that human frequency tuning is sharper than traditionally thought, and sharper than in commonly used animal models. Data from single auditory-nerve fibers occupy a pivotal position to examine this claim, but are not available for humans. A previous study reported sharper tuning in auditory-nerve fibers of macaque relative to the cat. A limitation of these and other single-fiber data is that frequency selectivity was measured with tonal threshold-tuning curves, which do not directly assess spectral filtering and whose shape is sharpened by cochlear nonlinearity. Our aim was to measure spectral filtering with wideband suprathreshold stimuli in the macaque auditory nerve. We obtained responses of single nerve fibers of anesthetized macaque monkeys and cats to a suprathreshold, wideband, multicomponent stimulus designed to allow characterization of spectral filtering at any cochlear locus. Quantitatively the differences between the two species are smaller than in previous studies, but consistent with these studies the filters obtained show a trend of sharper tuning in macaque, relative to the cat, for fibers in the basal half of the cochlea. We also examined differences in group delay measured on the phase data near the characteristic frequency versus in the low-frequency tail. The phase data are consistent with the interpretation of sharper frequency tuning in monkey in the basal half of the cochlea. We conclude that use of suprathreshold, wide-band stimuli supports the interpretation of sharper frequency selectivity in macaque nerve fibers relative to the cat, although the difference is less marked than apparent from the assessment with tonal threshold-based data.
Asunto(s)
Cóclea , Nervio Coclear , Animales , Haplorrinos , Nervio Coclear/fisiología , Cóclea/fisiología , Audición/fisiología , Macaca , Umbral Auditivo/fisiología , Estimulación AcústicaRESUMEN
The spiking activity of auditory nerve fibers (ANFs) transmits information about the acoustic environment from the cochlea to the central auditory system. Increasing age leads to degeneration of cochlear tissues, including the sensory hair cells and stria vascularis. Here, we aim to identify the functional effects of such age-related cochlear pathologies of ANFs. Rate-level functions (RLFs) were recorded from single-unit ANFs of young adult (n = 52, 3-12 months) and quiet-aged (n = 24, >36 months) Mongolian gerbils of either sex. RLFs were used to determine sensitivity and spontaneous rates (SRs) and were classified into flat-saturating, sloping-saturating, and straight categories, as previously established. A physiologically based cochlear model, adapted for the gerbil, was used to simulate the effects of cochlear degeneration on ANF physiology. In ANFs tuned to low frequencies (<3.5 kHz), SR was lower in those of aged gerbils, while an age-related loss of low-SR fibers was evident in ANFs tuned to high frequencies. These changes in SR distribution did not affect the typical SR versus sensitivity correlation. The distribution of RLF types among low-SR fibers, however, shifted toward that of high-SR fibers, specifically showing more fast-saturating and fewer sloping-saturating RLFs. A modeled striatal degeneration, which affects the combined inner hair cell and synaptic output, reduced SR but left RLF type unchanged. An additional reduced basilar membrane gain, which decreased sensitivity, explained the changed RLF types. Overall, the data indicated age-related changes in the characteristics of single ANFs that blurred the established relationships between SR and RLF types.NEW & NOTEWORTHY Auditory nerve fibers, which connect the cochlea to the central auditory system, change their encoding of sound level in aged gerbils. In addition to a general shift to higher levels, indicative of decreased sensitivity, level coding was also differentially affected in fibers with low- and high-spontaneous rates. Loss of low-spontaneous rate fibers, combined with a general decrease of spontaneous rate, further blurs the categorization of auditory nerve fiber types in the aged gerbil.
Asunto(s)
Cóclea , Nervio Coclear , Animales , Gerbillinae , Cóclea/fisiología , Nervio Coclear/fisiología , Envejecimiento/fisiología , Fibras Nerviosas/fisiología , Estimulación AcústicaRESUMEN
Spiral ganglion neurons (SGNs) facilitation properties can be recorded utilizing electrically evoked compound action potential (ECAP). While intracochlear variation of the ECAP threshold in relation to its electrode channel is reported, no study investigated its impact on facilitation. In this study, we quantified intracochlear variation of the facilitation properties in cochlear implants (CI) using ECAPs. We hypothesized that the facilitation effect is dependent on the electrode channel and its ECAP threshold. Therefore, ECAPs were recorded in 23 CI subjects. For each subject, five default (channel-derived) and up to two additional (threshold-derived) stimulation sites were defined. Facilitation was quantified by the paradigm introduced by (Hey et al., 2017) with optimized parameter settings. For each channel the maximum facilitated amplitude was determined by a series of ECAP measurements. A linear mixed-effects model was used to investigate the impact of the electrode channel and ECAP threshold on the maximum facilitated amplitude. The maximum facilitated amplitude was found to be dependent on the ECAP threshold and independent on the electrode channel. We conclude that the facilitation paradigm is a useful and feasible tool to gain local information on the SGNs temporal processing patterns.
Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Potenciales de Acción/fisiología , Potenciales Evocados , Ganglio Espiral de la Cóclea , Potenciales Evocados Auditivos/fisiología , Estimulación Eléctrica , Nervio Coclear/fisiologíaRESUMEN
Globular bushy cells (GBCs) of the cochlear nucleus play central roles in the temporal processing of sound. Despite investigation over many decades, fundamental questions remain about their dendrite structure, afferent innervation, and integration of synaptic inputs. Here, we use volume electron microscopy (EM) of the mouse cochlear nucleus to construct synaptic maps that precisely specify convergence ratios and synaptic weights for auditory nerve innervation and accurate surface areas of all postsynaptic compartments. Detailed biophysically based compartmental models can help develop hypotheses regarding how GBCs integrate inputs to yield their recorded responses to sound. We established a pipeline to export a precise reconstruction of auditory nerve axons and their endbulb terminals together with high-resolution dendrite, soma, and axon reconstructions into biophysically detailed compartmental models that could be activated by a standard cochlear transduction model. With these constraints, the models predict auditory nerve input profiles whereby all endbulbs onto a GBC are subthreshold (coincidence detection mode), or one or two inputs are suprathreshold (mixed mode). The models also predict the relative importance of dendrite geometry, soma size, and axon initial segment length in setting action potential threshold and generating heterogeneity in sound-evoked responses, and thereby propose mechanisms by which GBCs may homeostatically adjust their excitability. Volume EM also reveals new dendritic structures and dendrites that lack innervation. This framework defines a pathway from subcellular morphology to synaptic connectivity, and facilitates investigation into the roles of specific cellular features in sound encoding. We also clarify the need for new experimental measurements to provide missing cellular parameters, and predict responses to sound for further in vivo studies, thereby serving as a template for investigation of other neuron classes.