Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
2.
J Int Adv Otol ; 20(4): 289-300, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39159037

RESUMEN

People with single-sided deafness (SSD) or asymmetric hearing loss (AHL) have particular difficulty understanding speech in noisy listening situations and in sound localization. The objective of this multicenter study is to evaluate the effect of a cochlear implant (CI) in adults with single-sided deafness (SSD) or asymmetric hearing loss (AHL), particularly regarding sound localization and speech intelligibility with additional interest in electric-acoustic pitch matching. A prospective longitudinal study at 7 European tertiary referral centers was conducted including 19 SSD and 16 AHL subjects undergoing cochlear implantation. Sound localization accuracy was investigated in terms of root mean square error and signed bias before and after implantation. Speech recognition in quiet and speech reception thresholds in noise for several spatial configurations were assessed preoperatively and at several post-activation time points. Pitch perception with CI was tracked using pitch matching. Data up to 12 months post activation were collected. In both SSD and AHL subjects, CI significantly improved sound localization for sound sources on the implant side, and thus overall sound localization. Speech recognition in quiet with the implant ear improved significantly. In noise, a significant head shadow effect was found for SSD subjects only. However, the evaluation of AHL subjects was limited by the small sample size. No uniform development of pitch perception with the implant ear was observed. The benefits shown in this study confirm and expand the existing body of evidence for the effectiveness of CI in SSD and AHL. Particularly, improved localization was shown to result from increased localization accuracy on the implant side.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Humanos , Implantación Coclear/métodos , Masculino , Localización de Sonidos/fisiología , Femenino , Persona de Mediana Edad , Percepción del Habla/fisiología , Estudios Prospectivos , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Pérdida Auditiva Unilateral/fisiopatología , Estudios de Seguimiento , Anciano , Adulto , Europa (Continente) , Estudios Longitudinales , Resultado del Tratamiento , Inteligibilidad del Habla/fisiología , Percepción de la Altura Tonal/fisiología , Sordera/cirugía , Sordera/rehabilitación , Sordera/fisiopatología , Ruido
3.
Curr Opin Otolaryngol Head Neck Surg ; 32(5): 324-328, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39146020

RESUMEN

PURPOSE OF REVIEW: Here we explore the current literature on cochlear implantation of pediatric patients under the age of 5 years with single-sided deafness (SSD). RECENT FINDINGS: Single-sided deafness has been noted to cause developmental delays in speech, language, and cognition because of loss of binaural hearing. Currently, cochlear implantation is the only intervention capable of restoring binaural hearing for pediatric patients with SSD. Young children have been shown to have the greatest neuroplasticity of the auditory cortex before 4 years of age. Currently, only children over the age of 5 years are approved by the United States Food and Drug Administration (FDA) to undergo cochlear implantation for SSD. Cochlear implantation for SSD in patients under the age of 5 years has been performed on a limited basis and has been shown to have excellent results. SUMMARY: Cochlear implantation is a well tolerated and effective treatment for pediatric patients under the age of 5 years with SSD. Receiving cochlear implantation under the age of 5 years is critical for child development as neuroplasticity decreases after this age.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Unilateral , Humanos , Implantación Coclear/métodos , Pérdida Auditiva Unilateral/cirugía , Preescolar , Lactante , Implantes Cocleares , Resultado del Tratamiento
4.
Otol Neurotol ; 45(8): 878-886, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39066685

RESUMEN

HYPOTHESIS: Acoustic localization accuracy metrics currently employed in clinical literature both overestimate and underestimate performance benefit of cochlear implantation (CI) for single-sided deafness (SSD). BACKGROUND: Although localization in SSD with CI has been investigated, performance characterization has relied heavily on average error. Although attractively concise, this measure may misrepresent performance. Here, we characterize frequency-specific localization on a granular level in subjects with CI for SSD as a critical analysis of localization outcome metrics. METHODS: Eight CI recipients with SSD were recruited. Stimuli of broadband (BBN) and narrowband noise (NBN) at low (500 Hz), mid (1000 Hz), and high (4000 Hz) frequencies were presented in a semianechoic chamber. Localization accuracy was quantified in mean angular error (MAE) and linear regression slope. RESULTS: Use of a CI for SSD subjects improved localization performance by slope for all stimuli ( p ≤ 0.0033) to a level that was equal to normal-hearing controls at 1 and 4 kHz ( p ≥ 0.2281). MAE was also significantly improved for SSD subjects using CI for BBN stimuli ( p ≪ 0.0001); however, no statistically significant improvement in MAE was seen for NBN ( p ≥ 0.5773) with CI use. Descriptive analysis of individual subject performance highlights the reasons for contradictory results. CONCLUSION: There is inherent challenge in characterizing localization benefit for individuals with CI for SSD. Our data demonstrate the limitations of utilization of average error as the sole metric for outcome benefit. We emphasize the importance of continued research investigating alternative outcome measures as we work toward a more refined understanding of the potential benefits and limitations of cochlear implantation for SSD.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Localización de Sonidos , Humanos , Localización de Sonidos/fisiología , Masculino , Femenino , Persona de Mediana Edad , Implantación Coclear/métodos , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Anciano , Adulto , Resultado del Tratamiento , Estimulación Acústica/métodos
5.
Artículo en Chino | MEDLINE | ID: mdl-38965850

RESUMEN

Objectives: To investigate the outcomes of cochlear implantation in Mandarin-speaking cochlear implant (CI) users with single-sided deafness (SSD). Methods: This study was a single-center prospective cohort study. Eleven Mandarin-speaking adult SSD patients who underwent CI implantation at Capital Medical University Beijing Tongren Hospital from August 2020 to October 2021 were recruited, including 6 males and 5 females, with the age ranging from 24 to 50 years old. In a sound field with 7 loudspeakers distributed at 180°, we measured root-mean-square error(RMSE)in SSD patients at the preoperative, 1-month, 3-month, 6-month, and 12-month after switch-on to assess the improvement of sound source localization. The Mandarin Speech Perception (MSP) was used in the sound field to test the speech reception threshold (SRT) of SSD patients under different signal-to-noise locations in a steady-state noise under conditions of CI off and CI on, to reflect the head shadow effect(SSSDNNH), binaural summation effect(S0N0) and squelch effect(S0NSSD). The Tinnitus Handicap Inventory (THI) and the Visual Analogue Scale (VAS) were used to assess changes in tinnitus severity and tinnitus loudness in SSD patients at each time point. The Speech, Spatial and Qualities of Hearing Scale(SSQ) and the Nijmegen Cochlear Implantation Scale (NCIQ) were used to assess the subjective benefits of spatial speech perception and quality of life in SSD patients after cochlear implantation. SPSS 19.0 software was used for statistical analysis. Results: SSD patients showed a significant improvement in the poorer ear in hearing thresholds with CI-on compared with CI-off; The ability to localize the sound source was significantly improved, with statistically significant differences in RMSE at each follow-up time compared with the preoperative period (P<0.05). In the SSSDNNH condition, which reflects the head shadow effect, the SRT in binaural hearing was significantly improved by 6.5 dB compared with unaided condition, and the difference was statistically significant (t=6.25, P=0.001). However, there was no significant improvement in SRT between the binaural hearing condition and unaided conditions in the S0N0 and S0NSSD conditions (P>0.05). The total score of THI and three dimensions were significant decreased (P<0.05). Tinnitus VAS scores were significantly lower in binaural hearing compared to the unaided condition (P<0.001). The total score of SSQ, and the scores of speech and spatial dimensions were significant improved in binaural hearing compared to the unaided condition (P<0.001). There was no statistical difference in NCIQ questionnaire scores between preoperative and postoperative (P>0.05), and only the self-efficacy subscore showed a significant increase(Z=-2.497,P=0.013). Conclusion: CI could help Mandarin-speaking SSD patients restore binaural hearing to some extent, improve sound localization and speech recognition in noise. In addition, CI in SSD patients could suppress tinnitus, reduce the loudness of tinnitus, and improve subjective perceptions of spatial hearing and quality of life.


Asunto(s)
Implantación Coclear , Humanos , Masculino , Femenino , Implantación Coclear/métodos , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Pérdida Auditiva Unilateral/cirugía , Implantes Cocleares , Percepción del Habla , Adulto Joven , Localización de Sonidos , Acúfeno/cirugía , Sordera/cirugía , Audífonos
6.
Hear Res ; 450: 109076, 2024 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-38991628

RESUMEN

As part of a longitudinal study regarding the benefit of early cochlear implantation for children with single-sided deafness, the current work explored the children's daily device use, potential barriers to full-time device use, and the children's ability to understand speech with the cochlear implant (CI). Data were collected from 20 children with prelingual SSD who received a CI before the age of 2.5 years, from the initial activation of the sound processor until the children were 4.8 to 11.0 years old. Daily device use was extracted from the CI's data logging, while word perception in quiet was assessed using direct audio input to the children's sound processor. The children's caregivers completed a questionnaire about habits, motivations, and barriers to device use. The children with SSD and a CI used their device on average 8.3 h per day, corresponding to 63 % of their time spent awake. All children except one could understand speech through the CI, with an average score of 59 % on a closed-set test and 73 % on an open-set test. More device use was associated with higher speech perception scores. Parents were happy with their decision to pursue a CI for their child. Certain habits, like taking off the sound processor during illness, were associated with lower device use. Providing timely counselling to the children's parents, focused on SSD-specific challenges, may be helpful to improve daily device use in these children.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Implantación Coclear/instrumentación , Femenino , Masculino , Niño , Preescolar , Factores de Tiempo , Estudios Longitudinales , Personas con Deficiencia Auditiva/psicología , Personas con Deficiencia Auditiva/rehabilitación , Encuestas y Cuestionarios , Inteligibilidad del Habla , Pérdida Auditiva Unilateral/rehabilitación , Pérdida Auditiva Unilateral/psicología , Pérdida Auditiva Unilateral/fisiopatología , Pérdida Auditiva Unilateral/cirugía , Comprensión , Resultado del Tratamiento , Lenguaje Infantil , Sordera/psicología , Sordera/rehabilitación , Sordera/fisiopatología , Sordera/diagnóstico , Sordera/cirugía , Factores de Edad , Conducta Infantil , Motivación , Lactante
7.
Otol Neurotol ; 45(5): 513-520, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38511263

RESUMEN

OBJECTIVE: Unilateral hearing loss (UHL) in children is associated with speech and language delays. Cochlear implantation (CI) is currently the only rehabilitative option that restores binaural hearing. This study aims to describe auditory outcomes in children who underwent CI for UHL and to determine the association between duration of hearing loss and auditory outcomes. STUDY DESIGN: Retrospective case series. SETTING: Three tertiary-level, academic institutions. PATIENTS: Children <18 years with UHL who underwent CI between 2018 and 2021. INTERVENTION: Cochlear implantation. MAIN OUTCOME MEASURES: Speech perception and Speech, Spatial and Qualities of Hearing Scale (SSQ) were assessed postimplantation. Scores >50% on speech perception and SSQ scores >8 points were considered satisfactory. Associations between duration of UHL and implantation age and outcomes were assessed using Spearman's rank correlation. RESULTS: Of the 38 children included, mean age at CI was 7.9 ± 3.2 years and mean UHL duration was 5.0 ± 2.8 years. Mean datalogging was 8.1 ± 3.1 hours/day. Mean auditory testing scores were SSQ, 7.9 ± 1.2; BABY BIO, 68.1 ± 30.2%; CNC, 38.4 ± 28.4%; WIPI, 52.5 ± 23.1%. Scores >50% on CNC testing were achieved by 40% of patients. SSQ scores >8 points were reported by 78% (7/9) of patients. There were no significant correlations between UHL duration and auditory outcomes. CONCLUSION: Overall, children with UHL who undergo CI can achieve satisfactory speech perception scores and SSQ scores. There were no associations between duration of hearing loss and age at implantation with auditory outcomes. Multiple variables may impact auditory outcomes, including motivation, family support, access to technology, and consistent isolated auditory training postactivation and should be taken into consideration in addition to age at implantation and duration of UHL in determination of CI candidacy.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Unilateral , Percepción del Habla , Humanos , Niño , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Masculino , Femenino , Estudios Retrospectivos , Percepción del Habla/fisiología , Preescolar , Resultado del Tratamiento , Adolescente , Implantes Cocleares , Pruebas Auditivas , Lactante
8.
Otol Neurotol ; 45(4): 392-397, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38478407

RESUMEN

OBJECTIVE: To assess cochlear implant (CI) sound processor usage over time in children with single-sided deafness (SSD) and identify factors influencing device use. STUDY DESIGN: Retrospective, chart review study. SETTING: Pediatric tertiary referral center. PATIENTS: Children with SSD who received CI between 2014 and 2020. OUTCOME MEASURE: Primary outcome was average daily CI sound processor usage over follow-up. RESULTS: Fifteen children with SSD who underwent CI surgery were categorized based on age of diagnosis and surgery timing. Over an average of 4.3-year follow-up, patients averaged 4.6 hours/day of CI usage. Declining usage trends were noted over time, with the first 2 years postactivation showing higher rates. No significant usage differences emerged based on age, surgery timing, or hearing loss etiology. CONCLUSIONS: Long-term usage decline necessitates further research into barriers and enablers for continued CI use in pediatric SSD cases.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Humanos , Niño , Implantes Cocleares/efectos adversos , Estudios Retrospectivos , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Localización de Sonidos/fisiología , Sordera/cirugía , Sordera/rehabilitación , Percepción del Habla/fisiología , Resultado del Tratamiento
9.
Audiol Neurootol ; 29(4): 271-289, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38387454

RESUMEN

INTRODUCTION: For the treatment of single-sided deafness (SSD), common treatment choices include a contralateral routing of signals (CROS) hearing aid, a bone conduction device (BCD), and a cochlear implant (CI). The primary aim of this study was to compare speech understanding in noise and binaural benefits in adults with postlingual SSD between preoperative unaided baseline, preoperative CROS and BCD trial devices, and CI, following recommendations from a consensus protocol. In addition, we investigated the effect of masker type on speech understanding. METHODS: This was a prospective study with twelve participants. Binaural effects of head shadow, squelch, summation, and spatial release from masking were assessed by measuring speech reception thresholds (SRTs) in five different spatial target-masker configurations using two different maskers: two-talker babble (TTB), and speech-shaped noise (SSN). Preoperatively, participants were assessed unaided and with CROS and BCD trial devices. After cochlear implantation, participants were assessed at 1, 3, and 6 months post-activation. RESULTS: For TTB, significant improvements in SRT with a CI relative to preoperatively unaided were found in all spatial configurations. With CI at 6 months, median benefits were 7.8 dB in SSSDNAH and 5.1 dB in S0NAH (head shadow), 3.4 dB in S0N0 (summation), and 4.6 dB in S0NSSD and 5.1 dB in SAHNSSD (squelch). CROS yielded a significant head shadow benefit of 2.4 dB in SSSDNAH and a significant deterioration in squelch of 2.5 dB in S0NSSD and SAHNSSD, but no summation effect. With BCD, there was a significant summation benefit of 1.5 dB, but no head shadow nor squelch effect. For SSN, significant improvements in SRT with CI compared to preoperatively unaided were found in three spatial configurations. Median benefits with CI at 6 months were: 8.5 dB in SSSDNAH and 4.6 dB in S0NAH (head shadow), 1.4 dB in S0N0 (summation), but no squelch. CROS showed a significant head shadow benefit of 1.7 dB in SSSDNAH, but no summation effect, and a significant deterioration in squelch of 2.9 dB in S0NSSD and 3.2 dB in SAHNSSD. With BCD, no binaural effect was obtained. Longitudinally, we found significant head shadow benefits with a CI in SSSDNAH in both maskers at all postoperative intervals and in S0NAH at 3 and 6 months post-activation. CONCLUSION: With a CI, a clear benefit for masked speech perception was observed for all binaural effects. Benefits with CROS and BCD were more limited. CROS usage was detrimental to the squelch effect.


Asunto(s)
Conducción Ósea , Implantes Cocleares , Audífonos , Pérdida Auditiva Unilateral , Percepción del Habla , Humanos , Estudios Prospectivos , Masculino , Persona de Mediana Edad , Femenino , Anciano , Pérdida Auditiva Unilateral/rehabilitación , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/fisiopatología , Adulto , Implantación Coclear/instrumentación , Enmascaramiento Perceptual , Ruido
10.
Otolaryngol Head Neck Surg ; 170(5): 1449-1455, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38314892

RESUMEN

OBJECTIVE: To investigate the impact of daily cochlear implant (CI) use on speech perception outcomes among children with unilateral hearing loss (UHL). STUDY DESIGN: Multi-institutional retrospective case series of pediatric patients with UHL who underwent CI between 2018 to 2022. SETTING: Three tertiary children's hospitals. METHODS: Demographics were obtained including duration of deafness and age at CI. Best consonant-nucleus-consonant (CNC) word scores and data logs describing hours of CI usage were assessed postimplantation. Use of direct audio input (DAI) during rehabilitation was recorded. RESULTS: Twenty-seven children were included, with a mean age at CI of 7.8 years. Mean datalogging time was 7.8 ± 3.0 hours/day. 40.7% of children utilized daily DAI. The mean CNC score using the best score during the study period was 34.9%. There was no significant correlation between hours of CI usage and CNC score. There was a significant improvement in CNC score associated with whether the child used DAI during rehabilitation (CNC 50.91% [yes] vs 23.81% [no]), which remained significant when adjusting for age at CI, duration of deafness, and data log hours. CONCLUSION: Unlike children with bilateral hearing loss and CI, children with UHL and CI demonstrate no significant correlation between hours of daily CI usage and CNC scores. However, children who used DAI during postoperative rehabilitation achieved significantly higher CNC scores than those who did not. This suggests that rehabilitation focused on isolated listening with the implanted ear maybe critical in optimizing outcomes with CI in UHL patients.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Humanos , Niño , Masculino , Estudios Retrospectivos , Femenino , Pérdida Auditiva Unilateral/rehabilitación , Pérdida Auditiva Unilateral/cirugía , Preescolar , Resultado del Tratamiento , Percepción del Habla , Adolescente
11.
Int J Pediatr Otorhinolaryngol ; 177: 111857, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38244481

RESUMEN

OBJECTIVES: Single-sided deafness (SSD) can have consequences for a child's language, educational, and social development. A cochlear implant (CI) is the only device which can restore true binaural hearing, yet they are only approved for children with (SSD) over the age of five in the United States. Reports on speech perception outcomes for children implanted at a younger age are limited. The present study aims to examine the effects of age at implantation, duration of deafness, hearing loss etiology, and presence of additional disabilities on device usage and speech perception outcomes. METHODS: A retrospective chart review was used to examine demographics and speech perception outcomes for 18 children implanted at age five or younger. RESULTS: Speech perception results were highly variable, with some children deriving significant benefit and others demonstrating no sound awareness through the implant alone. Age at implantation and duration of deafness did not have a clear impact on outcomes. Device usage was low in many children, often those with anatomical abnormalities such as a hypoplastic cochlear nerve. There are challenges to assessing speech perception in young children with SSD, leading to a lack of standardized outcome measures. CONCLUSIONS: Early CI for children with SSD may improve speech perception, but benefit is not guaranteed. Candidacy evaluation should consider both medical and audiological factors, in addition to the degree of family support and realistic expectations. Caution is especially warranted in children with significant anatomical anomalies.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Percepción del Habla , Niño , Humanos , Preescolar , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Estudios Retrospectivos , Percepción del Habla/fisiología , Sordera/cirugía , Sordera/rehabilitación , Resultado del Tratamiento
12.
Audiol Neurootol ; 29(3): 228-238, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38190808

RESUMEN

INTRODUCTION: Cochlear implants (CIs) can restore binaural hearing in cases of single-sided deafness (SSD). However, studies with a high level of evidence in support of this phenomenon are lacking. The aim of this study is to analyze the effectiveness of CIs using several spatialized speech-in-noise tests and to identify potential predictors of successful surgery. METHODS: Ten cases underwent standard CI surgery (MEDEL-Flex24). The speech-in-noise test was used in three different spatial configurations. The noise was presented from the front (N0), toward the CI (NCI), and toward the ear (Near), while the speech was always from the front (S0). For each test, the speech-to-noise ratio at 50% intelligibility (SNR50) was evaluated. Seven different effects were assessed (summation, head shadow [HS], speech released of masking [SRM], and squelch for the CI and for the ear). RESULTS: A significant summation effect of 1.5 dB was observed. Contralateral PTA was positively correlated with S0N0-B and S0NCI-B (CIon and unplugged ear). S0N0-B results were positively correlated with S0N0-CIoff (p < 0.0001) and with S0Near-CIoff results (p = 0.004). A significant positive correlation was found between delay post-activation and HS gain for the CI (p = 0.005). Finally, the HS was negatively correlated with the squelch effect for the ear. CONCLUSION: CI benefits patients with SSD in noise and can improve the threshold for detecting low-level noise. Contralateral PTA could predict good postoperative results. Simple tests performed preoperatively can predict the likelihood of surgical success in reversing SSD.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Percepción del Habla , Humanos , Persona de Mediana Edad , Masculino , Femenino , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Pérdida Auditiva Unilateral/fisiopatología , Adulto , Anciano , Localización de Sonidos , Resultado del Tratamiento , Ruido
13.
Laryngoscope ; 134(2): 919-925, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37466238

RESUMEN

OBJECTIVE: To assess the perceived benefit of cochlear implant (CI) use for children with unilateral hearing loss (UHL) and evaluate whether perceived abilities are associated with performance on measures of speech recognition and spatial hearing. METHOD: Nineteen children with moderate-to-profound UHL underwent cochlear implantation. The Speech Spatial and Qualities of Hearing Questionnaire modified for children (SSQ-C) were completed by parental proxy pre-operatively and at 3, 6, 9, 12, 18, and 24 months post-activation. Linear mixed models evaluated perceived benefits over the study period. Pearson correlations assessed the association between subjective report and performance on measures of word recognition with the CI alone and spatial hearing (speech recognition in spatially-separated noise and sound source localization) in the combined condition (CI plus contralateral ear). RESULTS: For the SSQ-C, parents reported significant improvements with CI use as compared to pre-operative perceptions (p < 0.001); improved perceptions were either maintained or continued to improve over the 2-year post-activation period. Perceived benefit did not significantly correlate with word recognition with the CI alone or spatial hearing outcomes in the combined condition. CONCLUSION: Families of children with UHL observed benefits of CI use early after cochlear implantation that was maintained with long-term device use. Responses to subjective measures may broaden our understanding of the experiences of pediatric CI users with UHL in addition to outcomes on typical measures of CI performance. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:919-925, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Humanos , Niño , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Percepción del Habla/fisiología , Audición , Localización de Sonidos/fisiología , Resultado del Tratamiento
14.
Ear Hear ; 45(2): 316-328, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37726884

RESUMEN

OBJECTIVES: We investigated the long-term outcomes of children with single-sided deafness (SSD) after cochlear implant (CI) surgery, during and after rehabilitation, and compared the results of children with congenital, perilingual, and postlingual SSD. We evaluated the impact of SSD at age at onset and duration of deafness on their performance. DESIGN: Thirty-six children with SSD treated with CI participated in the study: 20 had congenital, seven perilingual (defined: >0 to 4 years), and nine had postlingual deafness (defined as >4 years of age). Their outcome with CI were measured on both subjective and objective scales: duration of device use, speech intelligibility in noise and in quiet, bilateral hearing and localization ability, quality of life and hearing, presence and loudness of tinnitus, and hearing ability of the better hearing ear. RESULTS: After a mean follow-up time of 4.75 years, 32 of the 36 children used their CI on a regular basis. The remaining four children were nonusers. These children had congenital SSD and were older than three years at the time of CI surgery. Overall, for congenital/perilingual and postlingual SSD, speech intelligibility in noise and the Speech, Spatial and Qualities of Hearing Scale (SSQ) speech subscore were significantly improved, as were their subjective and objective localization ability and hearing-related quality of life. Children with postlingual SSD benefited from the CI with regard to speech intelligibility, SSQ speech/spatial/total score, and localization error, and children with congenital SSD showed better results with a short duration of deafness of less than 3 years compared with those with a longer deafness period. CONCLUSIONS: Cochlear implantation is a successful treatment for children with congenital/perilingual or postlingual SSD. Results largely differed with respect to the onset and duration of deafness, and better outcomes were achieved by children with postlingual SSD and with a short duration of deafness. Our data also confirmed that children with congenital SSD should be implanted with a CI within three years of age.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Sensorineural , Pérdida Auditiva Unilateral , Percepción del Habla , Niño , Humanos , Implantación Coclear/métodos , Calidad de Vida , Audición , Sordera/cirugía , Sordera/rehabilitación , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Inteligibilidad del Habla , Resultado del Tratamiento
15.
Eur Arch Otorhinolaryngol ; 281(1): 95-105, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37378727

RESUMEN

PURPOSE: The current study aims to explore the therapeutic effect of cochlear implants (CIs) on tinnitus in patients with single-sided deafness or asymmetric hearing loss (SSD/AHL) as well as the improvement of tinnitus-related quality of life and psychological status. In addition, we also explored whether the levels of quality of life and psychological status was related to the patient's implantation intention. METHODS: Seven patients decided to receive cochlear implantation. Before and after implantation, they completed the Visual Analogue Scale (VAS) and the Tinnitus Questionnaire (TQ) to assess tinnitus severity, the Speech, Spatial and Qualities of Hearing Scale (SSQ), and the Medical Outcomes Study Short Form 36 Health Survey Questionnaire (SF-36) to assess the quality of life, the Simplified Coping Style Questionnaire (SCSQ) to assess psychological status. The other 8 SSD patients refused cochlear implantation. Their scores of the above questionnaires were compared with those of patients received implantation. RESULTS: Six months after cochlear implantations, the tinnitus perception, loudness, and annoyance significantly decreased compared to that before implantation. In terms of quality of life and physiological status, no statistically significant changes were detected in SSQ, SF-36, and SCSQ measurements. The score of annoyance subcategory of VAS and all subcategories of SSQ of patients refused implantation were better than those of implanted patients before implantation. CONCLUSIONS: These results suggest that CIs can significantly reduce tinnitus severity. Patients refused implantation had better status in the annoyance of VAS and all subcategories of SSQ scores than those received implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Acúfeno , Humanos , Implantación Coclear/métodos , Acúfeno/psicología , Calidad de Vida , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva/cirugía , Sordera/cirugía , Resultado del Tratamiento
16.
Ann Otol Rhinol Laryngol ; 133(3): 345-350, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38047440

RESUMEN

OBJECTIVES: Previous research has shown the positive effects of cochlear implantation in children with a short duration of single sided deafness (SSD). This case series assessed the impact of cochlear implantation in a cohort of children with a longer average duration of SSD. METHODS: A retrospective chart review of 6 children who received a cochlear implant for SSD. The mean age at time of cochlear implantation was 14.7 years old (median = 15.5, interquartile range (IQR) = 2.5) and mean duration of hearing loss before cochlear implantation was 10.8 years (median = 11.5, IQR = 5.3). Pre- and post-operative audiometric data for aided speech perception testing, sentence recognition in quiet, sentence recognition in noise, and word recognition scores were analyzed. RESULTS: When compared to preoperative hearing aid scores a 24% significant increase in median word score and a 64% significant increase in median sentence recognition score in quiet was observed at 12 months post-op. CONCLUSION: Cochlear implantation in children with a longer duration of SSD can provide benefit to speech recognition. LAY SUMMARY: This retrospective case series of children with prolonged single sided deafness demonstrated an improvement in word and sentence recognition within 12 months of receiving a cochlear implant.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Percepción del Habla , Niño , Humanos , Preescolar , Estudios Retrospectivos , Resultado del Tratamiento , Sordera/cirugía , Pérdida Auditiva Unilateral/cirugía
17.
Eur Arch Otorhinolaryngol ; 281(5): 2303-2312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38006462

RESUMEN

PURPOSE: Our aim was to investigate the course of the hearing capacity of the better-hearing ear in single-sided deafness (SSD) and asymmetric hearing loss (AHL) over time, in a multicenter study. METHODS: We included 2086 pure-tone audiograms from 323 patients with SSD and AHL from four hospitals and 156 private practice otorhinolaryngologists. We collected: age, gender, etiology, duration of deafness, treatment with CI, number and monosyllabic speech recognition, numerical rating scale (NRS) of tinnitus intensity, and the tinnitus questionnaire according to Goebel and Hiller. We compared the pure tone audiogram of the better-hearing ear in patients with SSD with age- and gender-controlled hearing thresholds from ISO 7029:2017. RESULTS: First, individuals with SSD showed a significantly higher hearing threshold from 0.125 to 8 kHz in the better-hearing ear compared to the ISO 7029:2017. The duration of deafness of the poorer-hearing ear showed no relationship with the hearing threshold of the better-hearing ear. The hearing threshold was significantly higher in typically bilaterally presenting etiologies (chronic otitis media, otosclerosis, and congenital hearing loss), except for Menière's disease. Second, subjects that developed AHL did so in 5.19 ± 5.91 years and showed significant reduction in monosyllabic word and number recognition. CONCLUSIONS: Individuals with SSD show significantly poorer hearing in the better-hearing ear than individuals with NH from the ISO 7029:2017. In clinical practice, we should, therefore, inform our SSD patients that their disease is accompanied by a reduced hearing capacity on the contralateral side, especially in certain etiologies.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Percepción del Habla , Acúfeno , Humanos , Acúfeno/cirugía , Pérdida Auditiva Unilateral/diagnóstico , Pérdida Auditiva Unilateral/etiología , Pérdida Auditiva Unilateral/cirugía , Audición , Sordera/cirugía , Pruebas Auditivas
18.
Am J Otolaryngol ; 45(2): 104138, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38101137

RESUMEN

PURPOSE: To investigate the benefits of cochlear implantation in adults with single-sided deafness (SSD) and asymmetric hearing loss (AHL). STUDY DESIGN: Prospective within-subjects repeated-measures. SETTING: Two tertiary cochlear implant centers. PATIENTS: Fourteen adults with severe-to-profound sensorineural hearing loss in the worse hearing ear and up to moderate SNHL in the better hearing ear. INTERVENTION: Cochlear implantation in the worse hearing ear. MAIN OUTCOME MEASURES: Consonant-nucleus-consonant (CNC) test, AzBio sentence test in noise, and lateralization testing were conducted preoperatively and at 3-, 6-, and 12-months post-activation. Patient-related outcomes were measured using the Speech, Spatial, and Qualities of Hearing Scale and Glasgow Benefit Inventory. Tinnitus Handicap Inventory was administered to subjects with tinnitus. RESULTS: Mean length of hearing loss in the worse hearing ear was 3.5 years. The mean CNC change scores from baseline were 54.8, 55.9, and 58.9 percentage points at 3-, 6-, and 12-months (p < 0.001). AzBio sentence test in noise demonstrated improved scores in all spatial configurations, although statistically significant in S0N0 (speech front, noise front) only. Lateralization testing showed significant improvement of 22.9, 24.5, and 24.0 percentage points at 3-, 6-, and 12 months post-activation (p = 0.002). All patient-related outcome measures revealed significant improvement. CONCLUSION: This study demonstrates improved speech perception in noise, sound lateralization, quality of life, and reduction in tinnitus perception in adults with SSD/AHL who undergo cochlear implantation. Our results add to the growing body of evidence that cochlear implant should be offered to this population.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Acúfeno , Adulto , Humanos , Implantación Coclear/métodos , Acúfeno/cirugía , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Pérdida Auditiva/cirugía , Percepción del Habla/fisiología , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación
19.
Otol Neurotol ; 44(8): e628-e634, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37504974

RESUMEN

OBJECTIVE: There is increasing interest in providing cochlear implants (CIs) in single-sided deafness (SSD) or asymmetric hearing loss (AHL). CI clinics have experienced a range of outcomes when seeking insurance coverage for patients. The study explored the extent to which CI clinics were able to secure insurance coverage and whether there were differences in successfully gaining such coverage. STUDY DESIGN: A SurveyMonkey questionnaire was used to collect data from US CI clinicians. Respondents were from all regions of the United States and represented a diversity of clinic types including hospitals, university-based clinics, private clinics, and schools. Data were collected during August-October 2021 from 105 respondents regarding their clinic's experience in gaining health insurance coverage for pediatric and adult patients who had SSD or AHL. Strategies that had been used for gaining coverage after an initial denial were explored. Interviews were conducted with some respondents to gain additional insights beyond the survey. RESULTS: There was a substantial increase in the number of SSD operations conducted after 2019, the year when the Food and Drug Administration (FDA) manufacturer criteria expanded to include CI in SSD and AHL. Respondents were grouped into four categories based on volume of SSD operations before 2019 (≤10, 11-29, 30-49, and ≥50). The number of SSD operations after 2019 went up in all categories except for the 10 or less category, which declined by 43%. A minority of respondents indicated that they were able to obtain SSD insurance coverage infrequently (5%) or almost never (8%). Peer-to-peer review was the most successful approach to overturning an initial denial. Many clinics note that they are nearly always declined for SSD coverage on the first submission and must appeal. CONCLUSIONS: There is variability in CI coverage for SSD and AHL. Some health insurance coverage is available for patients of all ages, although some clinics note more difficulty gaining coverage for children younger than 5 years because of the FDA criteria. Clinicians are most successful at gaining coverage after an initial denial with peer-to-peer review, although the process is time-consuming and delays surgery. Efforts to expand access to CIs in SSD for children and adults who may benefit might best be addressed by reflecting on what was done to expand insurance coverage in bilateral deafness-a process that depended on relevant clinical research; research presented to the FDA for guidelines change; information sharing with the general public and constituencies in the hearing loss field including professionals, parent, and consumer organizations; and ongoing advocacy for change with insurers. To date, outcomes research in young children with CI in SSD is limited. Until such research is conducted and published, insurers will continue to argue that other rehabilitative options are approved and available.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Adulto , Humanos , Niño , Preescolar , Sordera/cirugía , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva/cirugía
20.
Cochlear Implants Int ; 24(6): 342-353, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37490782

RESUMEN

OBJECTIVE: Identify and evaluate the effectiveness of methods for improving postoperative cochlear implant (CI) hearing performance in subjects with single-sided deafness (SSD) and asymmetric hearing loss (AHL). DATA SOURCES: Embase, PubMed, Scopus. REVIEW METHODS: Systematic review and narrative synthesis. English language studies of adult CI recipients with SSD and AHL reporting a postoperative intervention and comparative audiometric data pertaining to speech in noise, speech in quiet and sound localization were included. RESULTS: 32 studies met criteria for full text review and 6 (n = 81) met final inclusion criteria. Interventions were categorized as: formal auditory training, programming techniques, or hardware optimization. Formal auditory training (n = 10) found no objective improvement in hearing outcomes. Experimental CI maps did not improve audiologic outcomes (n = 9). Programed CI signal delays to improve synchronization demonstrated improved sound localization (n = 12). Hardware optimization, including multidirectional (n = 29) and remote (n = 11) microphones, improved sound localization and speech in noise, respectively. CONCLUSION: Few studies meeting inclusion criteria and small sample sizes highlight the need for further study. Formal auditory training did not appear to improve hearing outcomes. Programming techniques, such as CI signal delay, and hardware optimization, such as multidirectional and remote microphones, show promise to improve outcomes for SSD and AHL CI users.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Pérdida Auditiva , Localización de Sonidos , Percepción del Habla , Adulto , Humanos , Implantación Coclear/métodos , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Resultado del Tratamiento , Sordera/cirugía , Sordera/rehabilitación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA