Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.885
Filtrar
Más filtros

Intervalo de año de publicación
1.
Methods Mol Biol ; 2858: 219-227, 2025.
Artículo en Inglés | MEDLINE | ID: mdl-39433679

RESUMEN

Optomotor response/reflex (OMR) is a fast and efficient first-in-line visual screening method, especially for rodents. It has the potential to evaluate both the scotopic and photopic visions of nonrestrained animals through tracking head movement, providing a quantitative estimate of visual functions. In restrained animals, optokinetic response (OKR), compensatory eye movements for visual shifts in the surroundings, is utilized. Both OMR and OKR capitalize on an individual's innate reflex to stabilize images for the purpose of capturing clear vision. The two reflexes have similar reliability when evaluating stimulus luminance, contrast, spatial frequency, and velocity. They have emerged as powerful tools to evaluate the efficacy of pharmacological treatments and phenotypes of subjects undergoing study. With OMR and OKR accurately assessing visual acuity (VA) as well as contrast sensitivity (CS), the gold standards for measuring clinical vision, they provide reliable and easily accessible results that further eye and brain research. These methods of sight evaluation have been used in multiple animal models, particularly mice and zebrafish. Through OMR assays, these animal models have been utilized to investigate retinal degenerative diseases, helping researchers differentiate between worsening stages. Alongside tests such as optical coherence tomography (OCT), OMR provides confirmation of visual status, where increased OMR function often correlates with improved visual status. OMR has continued to be used outside of glaucoma in various retinal diseases, such as retinitis pigmentosa (RP), diabetic retinopathy, and age-related macular degeneration.In this chapter, we will introduce the concept and application of visual stimulus-induced head or eye reflex movement in different animal species and experimental models of eye diseases, such as glaucoma and other neurodegenerative disorders, and in patients with glaucoma.


Asunto(s)
Modelos Animales de Enfermedad , Glaucoma , Agudeza Visual , Animales , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Ratones , Humanos , Movimientos Oculares/fisiología , Sensibilidad de Contraste/fisiología , Pruebas de Visión/métodos , Pez Cebra/fisiología , Reflejo/fisiología
2.
Transl Vis Sci Technol ; 13(10): 23, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39405075

RESUMEN

Purpose: Night-time driving is dangerous, with increased crash rates, particularly involving vulnerable road users. A Night-Time Hazard Visibility Test (NHVT) was developed and validated by exploring the effects of refractive and cataract blur on performance. Methods: The NHVT comprised video clips of night-time roads from the driver's perspective, including different hazards (pedestrians, cyclists, and vehicles). Participants responded when they first recognized hazards requiring them to take evasive action to avoid a collision. In experiment 1, there were 16 young visually normal drivers (mean age = 22.3, standard deviation [SD] = 2.2 years) who completed 2 NHVT sets, viewed separately through best-correction and refractive blur (+1.00 diopter sphere [DS]). In experiment 2, a refined version of the NHVT was administered to an additional 16 young visually normal drivers (mean age = 21.1, SD = 1.2 years) with best-correction and cataract blur. The order of visual conditions and NHVT sets were counterbalanced. Results: In experiment 1, refractive blur significantly reduced photopic visual acuity (VA) compared to best-corrected vision (+0.09 vs. -0.21 logMAR, P < 0.001) and delayed response times by 0.69 seconds (3.10 vs. 2.41 seconds, P < 0.001) compared to best-corrected vision. In experiment 2, cataract blur reduced VA compared to best-corrected vision (+0.03 vs. -0.17 logMAR, P < 0.001) and delayed response times by 0.63 seconds (2.92 vs. 2.29 seconds, P < 0.001). Conclusions: The NHVT was sensitive to refractive and cataract blur, providing preliminary support of its validity as a measure of night-time hazard visibility performance. Translational Relevance: The NHVT has potential as an off-road assessment of visibility for night driving and application for assessment of drivers with different refractive corrections and ocular diseases.


Asunto(s)
Conducción de Automóvil , Catarata , Agudeza Visual , Humanos , Masculino , Femenino , Adulto Joven , Agudeza Visual/fisiología , Catarata/fisiopatología , Catarata/diagnóstico , Adulto , Pruebas de Visión/métodos , Errores de Refracción/diagnóstico , Errores de Refracción/fisiopatología , Accidentes de Tránsito/prevención & control
3.
J Vis ; 24(11): 2, 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39361273

RESUMEN

In binocular vision, the relative strength of the input from the two eyes can have significant functional impact. These inputs are typically balanced; however, in some conditions (e.g., amblyopia), one eye will dominate over the other. To quantify imbalances in binocular vision, we have developed the Dichoptic Contrast Ordering Test (DiCOT). Implemented on a tablet device, the program uses rankings of perceived contrast (of dichoptically presented stimuli) to find a scaling factor that balances the two eyes. We measured how physical interventions (applied to one eye) affect the DiCOT measurements, including neutral density (ND) filters, Bangerter filters, and optical blur introduced by a +3-diopter (D) lens. The DiCOT results were compared to those from the Dichoptic Letter Test (DLT). Both the DiCOT and the DLT showed excellent test-retest reliability; however, the magnitude of the imbalances introduced by the interventions was greater in the DLT. To find consistency between the methods, rescaling the DiCOT results from individual conditions gave good results. However, the adjustments required for the +3-D lens condition were quite different from those for the ND and Bangerter filters. Our results indicate that the DiCOT and DLT measures partially separate aspects of binocular imbalance. This supports the simultaneous use of both measures in future studies.


Asunto(s)
Sensibilidad de Contraste , Pruebas de Visión , Visión Binocular , Humanos , Visión Binocular/fisiología , Sensibilidad de Contraste/fisiología , Pruebas de Visión/métodos , Adulto , Masculino , Femenino , Percepción de Profundidad/fisiología , Reproducibilidad de los Resultados , Estimulación Luminosa/métodos , Adulto Joven , Ambliopía/fisiopatología , Ambliopía/diagnóstico
4.
Vestn Oftalmol ; 140(4): 26-32, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-39254387

RESUMEN

Accurate measurement of astigmatism parameters is the basis for prescribing modern means of optical correction. In recent years, another direction for correcting astigmatism has emerged - implantation of toric intraocular lenses (TIOL). PURPOSE: This study evaluates the diagnostic accuracy of various methods for measuring the parameters of regular astigmatism. MATERIAL AND METHODS: The study included 83 patients (122 eyes) with regular astigmatism exceeding 1.0 D. Three groups were formed depending on the type of astigmatism. Spherical and cylindrical (power and axis) components of refraction were determined using automatic refractometry. The results were refined with subjective tests: power and axis tests with a cross-cylinder. The criterion for diagnostic accuracy was the level of corrected visual acuity. To assess the impact of cylinder position on visual acuity, discrete deviations of the axis of trial astigmatic lenses from the correct position (determined based on subjective tests) were modeled at 5, 10, and 15 degrees in both clockwise and counterclockwise directions. RESULTS: In the overall sample of observations, coincidence of results was found only in one-third of cases, with a tendency for discrepancies in data between the two methods in nearly 70% of cases. Statistical processing revealed significant differences only in the magnitude of the cylinder in the group with against-the-rule astigmatism (p<0.0005). An increase in maximum visual acuity corrected based on subjective test data was noted. With a deviation of the cylinder axis from the correct position by 10-15 degrees, regardless of the type of astigmatism, a significant tendency for a decrease in visual acuity was identified. At the same time, with a deviation of the cylinder axis within 5 degrees, a significant decrease in visual acuity was noted only in with-the-rule astigmatism and counterclockwise deviation. CONCLUSION: To achieve maximum visual acuity in the correction of regular astigmatism, objective method data must be refined with subjective tests. The results of modeling the deviation of the axis of the corrective lens from the proper position can be considered when evaluating the functional outcomes of TIOL implantation.


Asunto(s)
Astigmatismo , Refracción Ocular , Agudeza Visual , Astigmatismo/diagnóstico , Astigmatismo/fisiopatología , Humanos , Refracción Ocular/fisiología , Masculino , Reproducibilidad de los Resultados , Femenino , Persona de Mediana Edad , Lentes Intraoculares , Adulto , Refractometría/métodos , Pruebas de Visión/métodos
5.
BMJ Open Ophthalmol ; 9(1)2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39306331

RESUMEN

OBJECTIVE: To determine the agreement between measurements of accommodative amplitude (AoA) in children using a specialised accommodative rule and measurments without it. METHODS: A total of 502 children underwent optometric examinations, including the measurement of visual acuity, objective and subjective refraction. AoA measurements were done with and without the Berens accommodative rule. The measurements of AoA were conducted monocularly using a -4 D lens. A fixation stick containing English letters equivalent to 20/30 visual acuity and a long millimetre ruler was used to measure AoA without the accommodative rule. This measurement was performed by the two trained examiners. The agreement between these methods was reported by 95% limits of agreement (LoA) and interclass correlation coefficient (ICC). RESULTS: The mean age of the participants was 11.7±1.3 years (range: 9-15 years) and 52.4% were male. The mean AoA with and without the accommodative rule was 20.02±6.02 D and 22.46±6.32 D, respectively. The 95% LoA between the two methods was -12.5 to 7.5 D, and the ICC was 0.67 (95% CI 0.63 to 0.70). The 95% LoA was narrower in higher age groups and males compared with females (18.92 vs 20.87). The 95% LoA was narrower in hyperopes (16.83 D) compared with emmetropes (18.37 D) and myopes (18.27 D). The agreement was not constant and decreased in higher values of AoA. CONCLUSION: There is a poor and non-constant agreement between the measurements of the AoA with and without the accommodative rule. The mean AoA was 2.5 D lower with using the accommodative rule.


Asunto(s)
Acomodación Ocular , Refracción Ocular , Agudeza Visual , Humanos , Acomodación Ocular/fisiología , Niño , Masculino , Femenino , Adolescente , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Pruebas de Visión/métodos , Errores de Refracción/diagnóstico , Errores de Refracción/fisiopatología , Optometría/métodos , Reproducibilidad de los Resultados
6.
Injury ; 55 Suppl 3: 111541, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39300626

RESUMEN

INTRODUCTION: Patients undergoing surgery due to hip fracture face an elevated risk of a subsequent fall during rehabilitation. An important contributing factor to this risk is deteriorated visual function, often responsive to intervention. This study aims to explore differences in visual acuity (VA) and stereovision (SV) between individuals with a history of fall-related hip injuries (study group) and age-matched controls, utilizing a mobile application (EuvisionTab, ET) to distinguish age-related visual decline from pathological vision. MATERIALS & METHODS: A total of 32 and 71 participants were enrolled in the study and control groups, respectively (mean age: 74.9 years, range: 60-96). Monocular logMAR VA was measured using a tablet by means of an adaptive threshold-search algorithm. SV was assessed using low-dot density static and dynamic random dot stereograms. An age-dependent reference limit for VA was established. For ET stereotests, the number of correctly identified optotypes out of 10 random presentations served as the measure for further comparisons. Visually impaired status in the study group was determined if patients failed either the VA threshold or the SV criteria. RESULTS: In the control group, an apparent but statistically nonsignificant decline in VA was observed, while stereovision remained stable and did not exhibit significant age-related variations based on ET stereotests. Conversely, the study group demonstrated significantly worse results in monocular VA (p = 0.0032) and for both stereotests (p = 0.018 for static, p = 0.036 for dynamic) according to paired samples t-test and chi-square test, respectively. Hip injuries were significantly associated with visual impairment (OR = 4.88, p = 0.0012). DISCUSSION: This study focuses on one possible risk factor of elderly falls, namely, vision impairment. Patients with visual decay present a higher incidence of hip injuries compared to age-matched controls. This data suggest that vision screening and, when feasible, restoration of visual function may contribute to the prevention of secondary falls, refractures, or contralateral fractures. A mobile-based screening protocol, executable as part of a postoperative bedside examination and independent of specialized eye care, can be proposed.


Asunto(s)
Accidentes por Caídas , Fracturas de Cadera , Trastornos de la Visión , Agudeza Visual , Humanos , Anciano , Masculino , Femenino , Agudeza Visual/fisiología , Fracturas de Cadera/cirugía , Fracturas de Cadera/fisiopatología , Anciano de 80 o más Años , Accidentes por Caídas/prevención & control , Trastornos de la Visión/fisiopatología , Trastornos de la Visión/prevención & control , Persona de Mediana Edad , Aplicaciones Móviles , Estudios de Casos y Controles , Pruebas de Visión , Percepción de Profundidad/fisiología
7.
Arq Bras Oftalmol ; 88(1): e20220375, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39319841

RESUMEN

PURPOSE: This study aimed to assess grating visual acuity and functional vision in children with congenital Zika syndrome. METHODS: Initial and final grating visual acuity was measured using Teller acuity cards. Cerebral vision impairment standardized tests were used to assess functional vision. Patients were referred to the early visual intervention program for visually disabled children. Neuroimaging was performed. RESULTS: In this study, 10 children were included with an age range of 1-37 months. Eight patients presented with macular atrophic scars. Neuroimaging revealed microcephaly and cerebral abnormalities in all patients. Low vision and cerebral vision impairment characteristics were observed in all children. The final grating visual acuity in this group varied from 3.00 to 0.81 logMAR. CONCLUSIONS: The grating visual acuity test revealed low vision in all children with congenital Zika syndrome. Functional vision evaluation revealed cerebral vision impairment characteristics in all patients, who were referred to the early visual intervention program. Visual acuity improved in six children.


Asunto(s)
Agudeza Visual , Infección por el Virus Zika , Humanos , Agudeza Visual/fisiología , Infección por el Virus Zika/congénito , Infección por el Virus Zika/complicaciones , Infección por el Virus Zika/fisiopatología , Lactante , Femenino , Masculino , Preescolar , Pruebas de Visión , Microcefalia/fisiopatología , Baja Visión/fisiopatología , Baja Visión/etiología
8.
Transl Vis Sci Technol ; 13(9): 20, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39292468

RESUMEN

Purpose: This study explored whether visual acuity (VA) can be inferred from self-reported ability to recognize everyday objects using a set of yes/no questions. Methods: Participants answered 100 yes/no questions designed to assess their ability to recognize familiar objects at typical viewing distances, such as distinguishing between a full moon and a half moon on a clear night. The questions demanded VA ranging from normal to severe vision impairment. Responses were analyzed using item response theory, and the results were compared with participants' VA values. Results: We recruited 385 participants from 4 sites in the United States. Participants had a mean age of 56.7 years with VA ranging from -0.3 to 2.0 logarithm of the minimum angle of resolution (logMAR) (mean = 0.58). A strong relationship was observed between participants' estimated vision ability and their VA (r = -0.72). The linear relationship can be used to predict each participant's VA based on their estimated vision ability. The average signed and unsigned prediction errors were 0 and 0.24 logMAR, respectively, with a coefficient of repeatability of 0.59 logMAR between the estimated VA and measured VA. The same linear function was used to determine the VA limit required for each question. For instance, the VA limit for the moon question was 1.0 logMAR. Conclusions: Yes/no questions about everyday visual activities have the potential to estimate an individual's VA. Future refinements may enhance reliability. Translational Relevance: The survey provides insights into the real-world visual capabilities of people with low vision, making it potentially useful for telehealth applications.


Asunto(s)
Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Adulto , Pruebas de Visión/métodos , Autoinforme , Anciano de 80 o más Años , Adulto Joven , Encuestas y Cuestionarios
9.
BMC Ophthalmol ; 24(1): 338, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134974

RESUMEN

BACKGROUND: This study aimed to investigate the difference between cycloplegic and noncycloplegic refraction and evaluate the pseudomyopia prevalence in Chinese preschool children during the outbreak of COVID-19. METHODS: A cross-sectional study was conducted in the Tongzhou District of Beijing, China. Refractive error was measured under both noncycloplegic and cycloplegic conditions with autorefraction. The difference between noncycloplegic and cycloplegic spherical equivalent refraction (SER) and pseudomyopia prevalence were analyzed. Pseudomyopia was defined as SER ≤-0.50D in precycloplegic assessments and >-0.50D in post-cycloplegic assessments. RESULTS: Out of the 1487 participants who were enrolled in the study, 1471 individuals (98.92%) between the ages of 3-6 years completed all required procedures. A statistically significant difference in refraction was observed between noncycloplegic and cycloplegic measurements, the median of difference in spherical equivalent refraction (SER) of 0.88D (dioptre)(0.50,1.38). There was a high intraclass correlation (ICC) between these two methods for cylinders (ICC = 0.864; 95% CI, 0.850-0.877). The median DSE for myopia, emmetropia and hyperopia were 0.25D (0.00, 0.38),0.25D (0.06, 0.50) and 1.00D (0.62, 1.38), an hypermetropes showed considerably greater differences than myopes and emmetropes (Kruskal-Wallis test, H = 231.023, P = 0.000). Additionally, girls displayed a greater DSE than boys. Furthermore, when comparing against-the-rule (ATR) and oblique astigmatism, it was found that with-the-rule (WTR) astigmatism had the largest DSE. The study found varying prevalence rates of myopia, emmetropia, and hyperopia with and without cycloplegia, which were 1.90% vs. 10.06%, 11.49% vs. 50.31%, and 86.61% vs. 39.63%, respectively. Additionally, the overall prevalence of pseudomyopia was determined to be 8.29%. Participants with pseudomyopia had a significantly higher mean difference in SER (DSE) compared to non-pseudomyopic participants. CONCLUSIONS: Cycloplegic refraction is more sensitive than a noncycloplegic one for measuring refractive error in preschool children. Pseudomyopia is prevalent in preschool children during the COVID-19 outbreak period. Our study indicates the possibility that cycloplegic refraction should be performed in preschool children routinely.


Asunto(s)
COVID-19 , Midriáticos , Refracción Ocular , Humanos , Masculino , Femenino , Estudios Transversales , Preescolar , Prevalencia , Refracción Ocular/fisiología , Niño , China/epidemiología , COVID-19/epidemiología , Errores de Refracción/epidemiología , Errores de Refracción/fisiopatología , SARS-CoV-2 , Miopía/epidemiología , Miopía/fisiopatología , Pruebas de Visión , Pueblos del Este de Asia
10.
Health Aff (Millwood) ; 43(8): 1073-1081, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39102604

RESUMEN

More than twelve million US adults ages forty and older are affected by vision impairment, and projections suggest that this number will double by 2050. Although most vision impairment can be eliminated with corrective lenses, many adults lack access to routine eye care. In this study, we analyzed detailed state-by-state Medicaid policies for 2022 and documented variability in coverage for adult vision services. Most fee-for-service Medicaid programs covered routine eye exams, although many did not cover glasses (twenty states) or low vision aids (thirty-five states), and about two-thirds of states with routine coverage required enrollee cost sharing. Managed care plans generally provided consistent or enhanced coverage relative to fee-for-service programs, although coverage sometimes varied between plans within a state. We estimated that about 6.5 million and 14.6 million adult enrollees resided in states without comprehensive coverage for routine eye exams and glasses, respectively. These findings reveal important gaps and opportunities for states to increase access to routine vision care.


Asunto(s)
Cobertura del Seguro , Medicaid , Humanos , Estados Unidos , Adulto , Cobertura del Seguro/estadística & datos numéricos , Accesibilidad a los Servicios de Salud , Persona de Mediana Edad , Planes de Aranceles por Servicios , Anteojos/economía , Pruebas de Visión , Masculino , Trastornos de la Visión/terapia , Femenino , Programas Controlados de Atención en Salud , Anciano
11.
Invest Ophthalmol Vis Sci ; 65(10): 33, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39177974

RESUMEN

Purpose: Crowding is exaggerated in central vision of strabismic amblyopia, impacting on reading ability. Crowding magnitude and interocular differences (IODs) in acuity are indicators for detection, assessment, and monitoring of treatment. Lateral masking (including contour interaction) also affects acuity and can mimic or ameliorate crowding. We investigated lateral masking/contour interaction and crowding impact on crowding magnitude and IOD measures in healthy and amblyopic pediatric and juvenile/adult groups using two Landolt C-tests with "fixed" arcmin separations. Methods: Acuity (logMAR) was measured with Landolt C-tests with specified 2.6' ("crowded") and 35' ("uncrowded") separations. Crowding magnitudes (crowded - uncrowded acuities) and IODs were calculated. Participants were 69 subjects with strabismic amblyopia (n = 39 pediatric, i.e. children ≤8 years of age), 31 subjects with anisometropic amblyopia (n = 14 pediatric), and 76 healthy controls (n = 36 pediatric). Subjects with amblyopia were subgrouped by acuity as low severity (<0.4 logMAR) or high severity (≥0.4 logMAR) using the 35' separation C-test. Results: Crowding magnitudes were greater in strabismic than in anisometropic amblyopia and control/fellow eyes. They were higher in pediatric control/fellow eyes than in juvenile/adult eyes. In high severity strabismic amblyopia, crowding magnitudes progressively and significantly reduced (slope = -0.17 ± 0.07, P < 0.05) with worsening acuity. IODs for this group were higher on the 2.6' C-test, but lower than expected. In high severity pediatric subjects with anisometropic amblyopia, seven of eight had lower IODs measured with the "crowded" than the "uncrowded" C-tests. Conclusions: These C-tests detect amblyopia but underestimate crowding in children and adults with high severity strabismic amblyopia. Separate isolated optotype acuity and crowding distance tests may better target specific functions, while minimizing the impact of masking.


Asunto(s)
Ambliopía , Agudeza Visual , Humanos , Ambliopía/diagnóstico , Ambliopía/fisiopatología , Niño , Masculino , Femenino , Agudeza Visual/fisiología , Adulto , Adolescente , Preescolar , Adulto Joven , Pruebas de Visión , Persona de Mediana Edad
12.
Sci Rep ; 14(1): 18392, 2024 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-39117752

RESUMEN

Windows provide access to daylight and outdoor views, influencing building design. Various glazing and window shade materials are used to mitigate glare, overheating and privacy issues, and they affect view clarity. Among them, we evaluated the effect of window films, electrochromic (EC) glass, and fabric shades on view clarity. We conducted an experiment with 50 participants using visual tests adapted from clinical vision tests (visual acuity, contrast sensitivity, color sensitivity) and images displayed on a computer monitor in a controlled laboratory. Window films and EC glass tints outperformed fabric shades in visual acuity, contrast sensitivity and view satisfaction with the exception of the darkest EC tint state and dark grey VLT 3% shade for color sensitivity and view satisfaction. The EC tints pose internal reflection issues and fabric shades are preferred for visual privacy. Window films and EC glass hinder participants' blue-green color discrimination while fabric shades also decrease red-yellow color discrimination. Visual acuity predicts view satisfaction and contrast sensitivity is the strongest predictor for visual privacy. Generally, higher visible light transmittance and lower solar reflectance (darker color) enhance human visual performance. The proposed workflow provides an experimental procedure, identifies the primary variables and establishes a predictive framework for assessing view clarity of fenestration.


Asunto(s)
Sensibilidad de Contraste , Agudeza Visual , Humanos , Sensibilidad de Contraste/fisiología , Femenino , Agudeza Visual/fisiología , Masculino , Adulto , Percepción de Color/fisiología , Deslumbramiento , Adulto Joven , Pruebas de Visión/métodos
13.
Optom Vis Sci ; 101(7): 451-463, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39110980

RESUMEN

SIGNIFICANCE: Angular Indication Measurement (AIM) is an adaptive, self-administered, and generalizable orientation-judgment method designed to interrogate visual functions. We introduce AIM Visual Acuity (VA) and show its features and outcome measures. Angular Indication Measurement VA's ability to detect defocus was comparable with that of an Early Treatment of Diabetic Retinopathy Study (ETDRS) letter chart and showed greater sensitivity to astigmatic blur. PURPOSE: This proof-of-concept study introduces Angular Indication Measurement and applies it to VA. METHODS: First, we compared the ability of AIM-VA and ETDRS to detect defocus and astigmatic blur in 22 normally sighted adults. Spherical and cylindrical lenses in the dominant eye induced blur. Second, we compared repeatability over two tests of AIM-VA and ETDRS. RESULTS: A repeated-measure analysis of variance showed a main effect for defocus blur and test. For the astigmatism experiment, an interaction between blur and orientation was found. Pairwise comparisons showed that AIM was more sensitive to astigmatic-induced VA loss than ETDRS. Bland-Altman plots showed small bias and no systematic learning effect for either test type and improved repeatability with more than two adaptive steps for AIM-VA. CONCLUSIONS: Angular Indication Measurement VA's ability to detect defocus was comparable with that of an ETDRS letter chart and showed greater sensitivity to induced astigmatic blur, and AIM-VA's repeatability is comparable with ETDRS when using two or more adaptive steps. Angular Indication Measurement's self-administered orientation judgment approach is generalizable to interrogate other visual functions, e.g., contrast, color, motion, and stereovision.


Asunto(s)
Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Masculino , Adulto , Femenino , Pruebas de Visión/métodos , Adulto Joven , Reproducibilidad de los Resultados , Persona de Mediana Edad , Astigmatismo/fisiopatología , Astigmatismo/diagnóstico
14.
Ophthalmic Physiol Opt ; 44(6): 1188-1201, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38989810

RESUMEN

INTRODUCTION: Degeneration in choroideremia, unlike typical centripetal photoreceptor degenerations, is centred temporal to the fovea. Once the fovea is affected, the nasal visual field (temporal retina) is relatively spared, and the preferred retinal locus shifts temporally. Therefore, when reading left to right, only the right eye reads into a scotoma. We investigate how this unique property affects the ability to read an eye chart. METHODS: Standard- and low-luminance visual acuity (VA) for right and left eyes were measured with the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. Letters in each line were labelled by column position. The numbers of letter errors for each position across the whole chart were summed to produce total column error scores for each participant. Macular sensitivity was assessed using microperimetry. Central sensitivity asymmetry was determined by the temporal-versus-nasal central macular difference and subsequently correlated to a weighted ETDRS column error score. Healthy volunteers and participants with X-linked retinitis pigmentosa GTPase regulator associated retinitis pigmentosa (RPGR-RP) were used as controls. RESULTS: Thirty-nine choroideremia participants (median age 44.9 years [IQR 35.7-53.5]), 23 RPGR-RP participants (median age 30.8 years [IQR 26.5-40.5]) and 35 healthy controls (median age 23.8 years [IQR 20.3-29.0]) were examined. In choroideremia, standard VA in the right eye showed significantly greater ETDRS column errors on the temporal side compared with the nasal side (p = 0.002). This significantly correlated with greater asymmetry in temporal-versus-nasal central macular sensitivity (p = 0.04). No significant patterns in ETDRS column errors or central macular sensitivity were seen in the choroideremia left eyes, nor in RPGR-RP and control eyes. CONCLUSION: Difficulty in tracking across lines during ETDRS VA testing may cause excess errors independent of true VA. VA assessment with single-letter optotype systems may be more suitable, particularly for patients with choroideremia, and potentially other retinal diseases with asymmetric central macular sensitivity or large central scotomas including geographic atrophy.


Asunto(s)
Coroideremia , Agudeza Visual , Campos Visuales , Humanos , Coroideremia/fisiopatología , Coroideremia/diagnóstico , Agudeza Visual/fisiología , Masculino , Adulto , Persona de Mediana Edad , Femenino , Campos Visuales/fisiología , Mácula Lútea/fisiopatología , Mácula Lútea/diagnóstico por imagen , Adulto Joven , Lectura , Tomografía de Coherencia Óptica/métodos , Pruebas de Visión/métodos , Pruebas del Campo Visual/métodos
15.
Ophthalmic Physiol Opt ; 44(6): 1072-1083, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39031645

RESUMEN

PURPOSE: SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults. METHODS: One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m2), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 2 Sw, Sw representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test. RESULTS: SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]). CONCLUSIONS: SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.


Asunto(s)
Sensibilidad de Contraste , Pruebas de Visión , Agudeza Visual , Humanos , Sensibilidad de Contraste/fisiología , Adulto , Femenino , Masculino , Persona de Mediana Edad , Pruebas de Visión/métodos , Pruebas de Visión/instrumentación , Adulto Joven , Reproducibilidad de los Resultados , Anciano , Agudeza Visual/fisiología , Anciano de 80 o más Años , Voluntarios Sanos
16.
Indian J Ophthalmol ; 72(11): 1653-1657, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38990639

RESUMEN

PURPOSE: To develop and validate MNREAD acuity charts in the Thai language (MNREAD-TH). METHODS: In total, 180 Thai sentences were generated using words specific to the primary 1-3 students. Each sentence contained 60 characters divided into three lines with even left and right margins and was evaluated by instructors in the education program in Thai. The selected 118 sentences were tested in 20 adults and 20 children by measuring reading time and recording the errors. Sentences with extremely high or low mean reading speeds were excluded. The remaining sentences were selected for contributing to the MNREAD-TH charts. For validation, the charts were tested in another 20 normal-sighted adult groups. RESULTS: In total, 118 sentences were tested on 20 adults (range: 23-58 years) and 20 primary school students (age: 8-9 years). The mean (SD) reading speeds in adult and children's groups were 134.09 (12.45) and 71.33 (10.77) words/min (wpm), respectively. After removing the sentences that deviated by ±1 SD from the mean reading speed, repeatedly had difficulty words, and had low subjective scoring, 60 matched sentences between the groups were selected to develop three versions of the MNREAD-TH chart. The intraclass correlation coefficients between charts were 0.85 for reading acuity, 0.94 for maximum reading speed, and 0.79 for critical print size. CONCLUSION: The MNREAD-TH charts can be reliably used for evaluating reading performance in Thai people for both children and adults with either normal sight or low vision. These charts are standardized and helpful in clinical trials involving reading.


Asunto(s)
Lectura , Pruebas de Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Tailandia , Adulto , Femenino , Masculino , Niño , Adulto Joven , Pruebas de Visión/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Lenguaje , Pueblos del Sudeste Asiático
17.
PLoS One ; 19(6): e0305036, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38848392

RESUMEN

PURPOSE: Stereopsis is a critical visual function, however clinical stereotests are time-consuming, coarse in resolution, suffer memorization artifacts, poor repeatability, and low agreement with other tests. Foraging Interactive D-prime (FInD) Stereo and Angular Indication Measurement (AIM) Stereo were designed to address these problems. Here, their performance was compared with 2-Alternative-Forced-Choice (2-AFC) paradigms (FInD Stereo only) and clinical tests (Titmus and Randot) in 40 normally-sighted and 5 binocularly impaired participants (FInD Stereo only). METHODS: During FInD tasks, participants indicated which cells in three 4*4 charts of bandpass-filtered targets (1,2,4,8c/° conditions) contained depth, compared with 2-AFC and clinical tests. During the AIM task, participants reported the orientation of depth-defined bars in three 4*4 charts. Stereoscopic disparity was adaptively changed after each chart. Inter-test agreement, repeatability and duration were compared. RESULTS: Test duration was significantly longer for 2-AFC (mean = 317s;79s per condition) than FInD (216s,18s per chart), AIM (179s, 60s per chart), Titmus (66s) or RanDot (97s). Estimates of stereoacuity differed across tests and were higher by a factor of 1.1 for AIM and 1.3 for FInD. No effect of stimulus spatial frequency was found. Agreement among tests was generally low (R2 = 0.001 to 0.24) and was highest between FInD and 2-AFC (R2 = 0.24;p<0.01). Stereoacuity deficits were detected by all tests in binocularly impaired participants. CONCLUSIONS: Agreement among all tests was low. FInD and AIM inter-test agreement was comparable with other methods. FInD Stereo detected stereo deficits and may only require one condition to identify these deficits. AIM and FInD are response-adaptive, self-administrable methods that can estimate stereoacuity reliably within one minute.


Asunto(s)
Percepción de Profundidad , Visión Binocular , Humanos , Percepción de Profundidad/fisiología , Adulto , Masculino , Femenino , Adulto Joven , Visión Binocular/fisiología , Persona de Mediana Edad , Pruebas de Visión/métodos , Anciano
18.
Transl Vis Sci Technol ; 13(6): 9, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38884546

RESUMEN

Purpose: To establish the reliability and validity of five performance-based activities of daily living task tests (ADLTT), to correlate structure to function, to evaluate the impact of visual impairment (VI) on age-related macular degeneration (AMD), and to develop new outcome measures. Methods: A multidisciplinary team developed five ADLTTs: (1) reading test (RT); (2) facial expression (FE) recognition; (3) item search (IS) task; (4) money counting (MC) task; and (5) making a drink (MD), tested with binocular and monocular vision. ADLTTs were tested for known-group (i.e., difference between AMD group and controls) and convergent (i.e., correlation to other measures of visual function), validity metrics, and test-retest reliability in 36 patients with VI (visual acuity (logMAR VA > 0.4) in at least one eye caused by AMD versus 36 healthy controls without VI. Results: Compared to controls, AMD patients had a slower reading speed (-77.41 words/min; P < 0.001); took longer to complete MC using monocular worse eye and binocular vision (15.13 seconds and 4.06 seconds longer compared to controls, respectively; P < 0.001); and MD using monocular worse eye vision (9.37 sec; P = 0.033), demonstrating known-group validity. Only RT and MC demonstrated convergent validity, showing correlations with VA, contrast sensitivity, and microperimetry testing. Moderate to good test-retest reliability was observed for MC and MD (interclass correlation coefficient = 0.55 and 0.77; P < 0.001) using monocular worse eye vision. Conclusions: Real-world ADL functioning associated with VI-related AMD can be assessed with our validated ADLTTs, particularly MC and MD. Translational Relevance: This study validates visual function outcome measures that are developed for use in future clinical practice and clinical trials.


Asunto(s)
Actividades Cotidianas , Degeneración Macular , Agudeza Visual , Humanos , Degeneración Macular/fisiopatología , Degeneración Macular/diagnóstico , Femenino , Masculino , Anciano , Agudeza Visual/fisiología , Reproducibilidad de los Resultados , Anciano de 80 o más Años , Persona de Mediana Edad , Pruebas de Visión/métodos , Visión Binocular/fisiología , Lectura
19.
Doc Ophthalmol ; 149(2): 87-98, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38916779

RESUMEN

PURPOSE: Accurate objective assessment of visual acuity is crucial, particularly in cases of suspected malingering, or when the patient's inability to cooperate makes standard psychophysical acuity tests unreliable. The P300 component of the event-related potentials offers a potential solution and even allows for the use of standard optotypes like the Landolt C. However, low-vision patients with large eccentric visual field defects often struggle to locate the Landolt C gap quickly enough for a P300 to be reliably produced. METHODS: Addressing this challenge, we introduce a novel optotype (the "FreiBurger") with a critical detail that extends through the optotype's center. Two experiments, with 16 and 12 participants, respectively, were conducted. In the first, psychophysical acuity estimates were obtained with both the FreiBurger and the Landolt C. In the second, we tested the performance of the FreiBurger, relative to the Landolt C, in eliciting a P300 with undegraded vision, simulated low vision, and in a simulated combination of low vision and visual field constriction. RESULTS: Comparable psychophysical acuity values (average difference 0.03 logMAR) were obtained for both optotypes. In the P300 recordings, both optotypes produced similar P300 responses under conditions of undegraded vision and low vision. However, with the combination of low vision and constricted visual field, the P300 could only be reliably obtained with the FreiBurger, while the amplitude was drastically reduced with the Landolt C (9.1 µV vs. 2.2 µV; p < 0.0005). CONCLUSION: The new optotype extends the applicability of P300-based acuity estimation to the frequently encountered combination of low vision and constricted visual field, where Landolt C optotypes fail. Although impairments were simulated in the present study, we assume that the advantages of the new optotype will also manifest in patients with such impairments. We furthermore expect the advantages to apply to time-sensitive psychophysical examinations as well.


Asunto(s)
Potenciales Relacionados con Evento P300 , Pruebas de Visión , Agudeza Visual , Campos Visuales , Humanos , Agudeza Visual/fisiología , Masculino , Femenino , Adulto , Potenciales Relacionados con Evento P300/fisiología , Adulto Joven , Campos Visuales/fisiología , Psicofísica , Diseño de Equipo , Baja Visión/fisiopatología , Baja Visión/diagnóstico
20.
Medicine (Baltimore) ; 103(25): e38488, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38905427

RESUMEN

To evaluate the usefulness of the Tokyo Metropolitan Government's Eye Health Screening Program for 3-year-old children, which combines the Single-Picture Optotype Visual Acuity Chart (SPVAC) and Spot™ Vision Screener (SVS) tests. This was a retrospective, observational, matched study. Patients who underwent the eye health screening program and had abnormalities were classified into 3 groups according to the outcomes of the SPVAC (SPVAC-passed, SPVAC-P; SPVAC-failed, SPVAC-F) and SVS (SVS-passed, SVS-P; SVS-failed, SVS-F) tests as follows: SPVAC-P/SVS-F, SPVAC-F/SVS-P, and SPVAC-F/SVS-F. We evaluated the age at examination, SPVAC and SVS test success rates, and SVS refractive power. Additionally, the rates of refractive error, amblyopia, and strabismus were compared among the 3 groups. The SPVAC-P/SVS-F, SPVAC-F/SVS-P, and SPVAC-F/SVS-F groups comprised 158, 28, and 74 eyes, respectively. The mean age was 37.4 months. The success rates of the SPVAC and SVS tests were 69.8% and 96.2%, respectively. The mean SVS hyperopia value in the SPVAC-F/SVS-F group (2.71 ±â€…1.50 D) was significantly higher than that of the SPVAC-P/SVS-F group. The mean SVS astigmatism and myopia values were -2.21 diopter (D) ±â€…1.09 D and -3.40 ±â€…1.82 D, respectively; they did not differ significantly from that of the SPVAC-P/SVS-F group. Significant differences were observed in the refractive error, amblyopia, and strabismus rates among the 3 groups. Regarding disease determination, no significant difference was observed among participants who passed and failed the SPVAC test, regardless of the outcome of the other test. However, a significant difference was observed between those passing and failing the SVS tests. The SPVAC method used to screen 3-year-old children should be modified to commence at 42 months of age or be replaced with a single Landolt C test. The SVS test is useful for screening younger patients. Furthermore, the SVS test showed that the degree of hyperopia was higher in patients who did not pass the SPVAC test.


Asunto(s)
Estrabismo , Selección Visual , Agudeza Visual , Humanos , Estudios Retrospectivos , Preescolar , Masculino , Femenino , Selección Visual/métodos , Selección Visual/instrumentación , Tokio , Estrabismo/diagnóstico , Errores de Refracción/diagnóstico , Ambliopía/diagnóstico , Pruebas de Visión/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA