RESUMEN
Purpose To assess long-term geometric changes of the mitral valve apparatus using cardiac CT in individuals who underwent cardiac resynchronization therapy (CRT). Materials and Methods Participants from a randomized controlled trial with cardiac CT examinations before CRT implantation and at 6 months follow-up (Clinicaltrials.gov identifier NCT01323686) were invited to undergo an additional long-term follow-up cardiac CT examination. The geometry of the mitral valve apparatus, including mitral valve annulus area, A2 leaflet angle, tenting height, and interpapillary muscle distances, were assessed. Geometric changes at the long-term follow-up examination were reported as mean differences (95% CI), and the Pearson correlation test was used to assess correlation between statistically significant geometric changes and left ventricular (LV) volumes and function. Results Thirty participants (mean age, 68 years ± 9 [SD]; 25 male participants) underwent cardiac CT imaging after a median long-term follow-up of 9.0 years (IQR, 8.4-9.4). There were reductions in end-systolic A2 leaflet angle (-4° [95% CI: -7, -2]), end-systolic tenting height (-1 mm [95% CI: -2, -1]), and end-systolic and end-diastolic interpapillary muscle distances (-4 mm [95% CI: -6, -2]) compared with pre-CRT implantation values. The mitral valve annulus area remained unchanged. LV end-diastolic and end-systolic volumes decreased (-68 mL [95% CI: -99, -37] and -67 mL [95% CI: -96, -39], respectively), and LV ejection fraction increased (13% [95% CI: 7, 19]) at the long-term follow-up examination. Changes in interpapillary muscle distances showed moderate to strong correlations with LV volumes (r = 0.42-0.72; P < .05), while A2 leaflet angle and tenting height were not correlated to LV volumes or function. Conclusion Among the various geometric changes in the mitral valve apparatus after long-term CRT, the reduction in interpapillary muscle distances correlated with LV volumes while the reduced A2 leaflet angle and tenting height did not correlate with LV volumes. Keywords: Mitral Valve Apparatus, Cardiac Resynchronization Therapy, Cardiac CT Supplemental material is available for this article. © RSNA, 2024.
Asunto(s)
Terapia de Resincronización Cardíaca , Válvula Mitral , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Anciano , Válvula Mitral/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Persona de Mediana Edad , Estudios de Seguimiento , Resultado del TratamientoRESUMEN
AIMS: Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS: Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). CONCLUSION: The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. REGISTRATION: Clinical Trials.gov Identifier: NCT03012490.
Asunto(s)
COVID-19 , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Anciano , Terapia de Resincronización Cardíaca/métodos , Persona de Mediana Edad , Resultado del Tratamiento , Hospitalización/estadística & datos numéricos , Tecnología de Sensores Remotos , Encuestas y Cuestionarios , Telemedicina , Calidad de VidaRESUMEN
In patients with dyssynchronous heart failure (DHF), cardiac conduction abnormalities cause the regional distribution of myocardial work to be non-homogeneous. Cardiac resynchronization therapy (CRT) using an implantable, programmed biventricular pacemaker/defibrillator, can improve the synchrony of contraction between the right and left ventricles in DHF, resulting in reduced morbidity and mortality and increased quality of life. Since regional work depends on wall stress, which cannot be measured in patients, we used computational methods to investigate regional work distributions and their changes after CRT. We used three-dimensional multi-scale patient-specific computational models parameterized by anatomic, functional, hemodynamic, and electrophysiological measurements in eight patients with heart failure and left bundle branch block (LBBB) who received CRT. To increase clinical translatability, we also explored whether streamlined computational methods provide accurate estimates of regional myocardial work. We found that CRT increased global myocardial work efficiency with significant improvements in non-responders. Reverse ventricular remodeling after CRT was greatest in patients with the highest heterogeneity of regional work at baseline, however the efficacy of CRT was not related to the decrease in overall work heterogeneity or to the reduction in late-activated regions of high myocardial work. Rather, decreases in early-activated regions of myocardium performing negative myocardial work following CRT best explained patient variations in reverse remodeling. These findings were also observed when regional myocardial work was estimated using ventricular pressure as a surrogate for myocardial stress and changes in endocardial surface area as a surrogate for strain. These new findings suggest that CRT promotes reverse ventricular remodeling in human dyssynchronous heart failure by increasing regional myocardial work in early-activated regions of the ventricles, where dyssynchrony is specifically associated with hypoperfusion, late systolic stretch, and altered metabolic activity and that measurement of these changes can be performed using streamlined approaches.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Modelación Específica para el Paciente , Humanos , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Masculino , Femenino , Anciano , Persona de Mediana Edad , Modelos Cardiovasculares , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Biología Computacional , Remodelación Ventricular/fisiologíaRESUMEN
BACKGROUND: Chagas cardiomyopathy (ChCC) is one of the causes of the implantation of pacemakers (PM) in many patients and has been associated with an adverse prognosis. OBJECTIVES: To compare the prognosis of the chagasic and non-chagasic populations undergoing PM and cardiac resynchronizer implantation. METHODS: Observational, retrospective study, which analyzed a cohort of patients who underwent implantation of these devices, in a tertiary center, from October 2007 to December 2017, comparing the chagasic group with non-chagasic patients. The non-parametric Kaplan-Meier method was used to calculate patient survival. The significance level adopted in the statistical analysis was 5%. The primary outcome was mortality from any cause, while the secondary outcomes were the occurrence of hospitalization and the combination of hospitalization and death. RESULTS: A total of 911 patients were included, of which 23.4% had ChCC. In a Cox analysis adjusted for sex and age, Chagas disease (ChD) was not associated with an increased risk of death (HR: 1.14, CI:95%, 0.86-1.51, p=0.365), hospitalization (HR: 0.79, CI:95%, 0.61-1.04, p=0.09) or combined outcome of death and hospitalization (HR: 0.90, CI:95%, 0.72-1 .12, p=0.49). CONCLUSIONS: ChD was not associated with an increased risk of death, hospitalization, or combined outcome of death and hospitalization, even after adjustment for sex and age. These results contrast with those of previous studies and suggest changes in the quality of care of patients with cardiomyopathy.
FUNDAMENTO: A cardiomiopatia chagásica (CCh) é responsável pelo implante de marca-passo (MP) em muitos pacientes, tendo sido associada a prognóstico adverso. OBJETIVOS: Comparar o prognóstico da população chagásica e não chagásica submetida ao implante de MP e ressincronizador cardíaco. MÉTODOS: Estudo observacional, retrospectivo, que analisou coorte de pacientes submetidos a implante desses dispositivos, em centro terciário, de outubro 2007 a dezembro de 2017, comparando o grupo de pacientes chagásicos com os não-chagásicos. O método não paramétrico de Kaplan-Meier foi utilizado para calcular a sobrevida dos pacientes. O nível de significância adotado na análise estatística foi de 5%. O desfecho primário foi a mortalidade por qualquer causa, enquanto os desfechos secundários foram a ocorrência de internação e o desfecho combinado internação e morte. RESULTADOS: Um total de 911 pacientes foram incluídos, sendo que 23,4% apresentavam CCh. Em análise de Cox ajustada por sexo e idade, a doença de Chagas (dCh) não esteve associada ao risco aumentado de morte (HR: 1,14, IC:95%, 0,86-1,51, p=0,365), internação (HR: 0,79, IC:95%, 0,61-1,04, p=0,09) ou desfecho combinado morte e internação (HR: 0,90, IC:95%, 0,72-1,12, p=0,49). CONCLUSÕES: A dCh não se associou ao aumento do risco de morte, internação, ou desfecho combinado morte e internação, mesmo após ajuste para sexo e idade. Tais resultados se contrapõem aos de estudos prévios e sugerem modificação da qualidade do cuidado ao paciente cardiopata.
Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatía Chagásica , Hospitalización , Marcapaso Artificial , Centros de Atención Terciaria , Humanos , Masculino , Femenino , Cardiomiopatía Chagásica/mortalidad , Cardiomiopatía Chagásica/terapia , Cardiomiopatía Chagásica/fisiopatología , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Pronóstico , Hospitalización/estadística & datos numéricos , Estimación de Kaplan-Meier , Factores de RiesgoRESUMEN
BACKGROUND: The aim of this study is to assess the predictive efficacy of real-time three-dimensional echocardiography (RT-3DE) and QRS wave duration in determining the response to cardiac resynchronization therapy (CRT) and assessing left ventricular systolic function pre- and post-CRT device implantation. METHOD: A total of 51 patients with heart failure undergoing CRT at the Second Affiliated Hospital of Nantong University between January 1, 2013, and October 31, 2020, were enrolled in this study. Traditional two-dimensional echocardiography and RT-3DE were performed pre and post-CRT, with QRS wave width data from electrocardiograms and additional clinical information collected. Patients were categorized into CRT responder (n = 36) and CRT non-responder (n = 15) groups based on their response to CRT device implantation. Comparative analyses were conducted on the general characteristics of both groups, as well as the predictive efficacy of RT-3DE and QRS wave width for CRT responsiveness and left ventricular systolic function. Data on the standard deviation (Tmsv16-SD, Tmsv12-SD, Tmsv6-SD) and maximum difference (Tmsv16-Dif, Tmsv12-Dif, Tmsv6-Dif) of left ventricular end-systolic volume (LVESV) at segments 16, 12, and 6, as well as QRS wave width, were collected and analyzed. RESULTS: The indicators Tmsv6-Dif, Tmsv12-Dif, Tmsv16-Dif, Tmsv6-SD, Tmsv12-SD, Tmsv16-SD, and QRS wave width exhibited significantly higher values in the CRT responder group when compared to the CRT non-responder group (P < 0.05). Among these, Tmsv16-SD demonstrated superior predictive performance for post-CRT response, with a sensitivity of 88.9%, specificity of 80.0%, and a diagnostic cut-off value of 6.19%. This predictive capability exceeded that of the conventional indicator, QRS wave width. CONCLUSION: RT-3DE enables accurate prediction of post-CRT patient response and significantly facilitates quantitative assessment of CRT therapy efficacy.
Asunto(s)
Terapia de Resincronización Cardíaca , Ecocardiografía Tridimensional , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Masculino , Femenino , Ecocardiografía Tridimensional/métodos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Función Ventricular Izquierda/fisiología , Valor Predictivo de las Pruebas , Resultado del Tratamiento , ElectrocardiografíaRESUMEN
BACKGROUND: Cardiac resynchronization therapy (CRT) is a standard treatment for patients with heart failure and electrical dyssynchrony. Cardiac magnetic resonance (CMR) is the gold standard for assessing left ventricular (LV) function. However, the feasibility of using CMR with active CRT is still uncertain. PURPOSE: To assess the feasibility of a CRT "off-on" protocol during CMR and measure the acute effects of CRT interruption on LV function. METHODS: Patients underwent CMR before (pre-CRT) and 6 months after (post-CRT) an MR-conditional CRT defibrillator implantation. The post-CRT scan included two complete sets of cine images, one with inactive (post-CRTOFF) and one with active CRT (post-CRTON), maintaining a continuous connection between device and programmer. RESULTS: Out of 29 enrolled patients, 8 (28%) had complete and analyzable post-CRT data. Unsuccessful procedures were attributed to connection problems between the CRT device and the programmer (n = 10), poor image quality (n = 7), and lack of patient cooperation (n = 4). LV ejection fraction significantly increased between pre-CRT scan (28.1%) and both post-CRTOFF (37.9%; p = 0.046) and post-CRTON CMR (35.0%; p = 0.037), with a nonstatistically significant trend toward decreased LV volumes. No adverse events or significant changes in device electrical parameters (including battery level) were detected during the post-CMR scan period. CONCLUSION: A CRT "off-on" protocol during CMR studies can be safely executed in patients with an MR-conditional CRT defibrillator. However, technical improvements are needed to facilitate high-quality scans during active CRT. Favorable changes in LV function induced by CRT remodeling were not acutely reversed with the interruption of electrical therapy.
Asunto(s)
Terapia de Resincronización Cardíaca , Estudios de Factibilidad , Insuficiencia Cardíaca , Imagen por Resonancia Cinemagnética , Humanos , Terapia de Resincronización Cardíaca/métodos , Masculino , Femenino , Imagen por Resonancia Cinemagnética/métodos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Anciano , Resultado del Tratamiento , Persona de Mediana Edad , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia , Disfunción Ventricular Izquierda/fisiopatología , Reproducibilidad de los ResultadosRESUMEN
Cardiac resynchronization therapy with implantable cardioverter defibrillators (CRT-Ds) are established therapy options for patients suffering from heart failure (HF). Several aspects of HF modification have yet to be described regarding etiology-dependent outcome differences in the long-term.The Mannheim CArdiac Resynchronization TherApy RetrospeCtive ObservAtioNAl (MARACANA) Registry retrospectively included all patients provided with CRTs in our center from 2013 to 2021. CRT-D recipients (n = 380) were grouped to either ischemic cardiomyopathy (ICM, n = 206) or nonischemic cardiomyopathy (NICM, n = 174). Both groups were compared regarding survival, left ventricular ejection fraction (LVEF), hospitalizations due to HF, intrinsic and paced QRS width, NYHA classification, and several further aspects of HF modification in the long-term (59.1 ± 4.81 months).Patients with ICM were older (73.3 ± 8.4 versus 67.7 ± 10.8 years) and predominantly male (86.4 versus 74.7%) and presented with higher creatinine values (1.57 ± 0.92 versus 1.31 ± 0.66 mg/dL, each P < 0.05) at baseline. The mean survival for patients with NICM was better (51.9 ± 1.2 versus 54.4 ± 1.1 months, P = 0.03). Improvements in NYHA (2.93 ± 0.4 versus 2.79 ± 0.5-2.19 ± 0.7 versus 1.79 ± 0.7) and LVEF (26.4 ± 6.8 versus 27% ± 6.9% to 35.7 ± 9.6 versus 44 ± 11%, each P < 0.05) were similar for both groups after 5 years. Patients with ICM experienced more hospitalizations due to HF within the first year (odds ratio 1.9, P < 0.05), whereas electrical remodeling was more impressive for NICM (QRS width 157.1 ± 19.4 milliseconds versus intrinsic 116.6 ± 12.7 milliseconds and paced 131.9 ± 21 milliseconds after 5 years, both P < 0.05).Patients with HF might experience long-term improvements in functional status and left ventricular reverse remodeling following CRT-D, regardless of underlying etiology. Alterations in some aspects of HF modification could be influenced by time- and etiology-associated comorbidities.
Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Desfibriladores Implantables , Insuficiencia Cardíaca , Isquemia Miocárdica , Humanos , Masculino , Terapia de Resincronización Cardíaca/métodos , Femenino , Anciano , Estudios Retrospectivos , Cardiomiopatías/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/fisiopatología , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/terapia , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Volumen Sistólico/fisiología , Resultado del Tratamiento , Anciano de 80 o más Años , Sistema de Registros , Hospitalización/estadística & datos numéricos , Función Ventricular Izquierda/fisiologíaRESUMEN
Mitochondrial dysfunction contributes significantly to the development of atrial fibrillation (AF). Conflicting data regarding the atrial pacing and the risk of AF existed, and the impact of atrial pacing on mitochondrial function remains unknown. Therefore, we sought to examine the association between atrial pacing percentage and mitochondrial function in patients with cardiovascular implantable electronic devices (CIEDs) with atrial pacing capability. This is a cross-sectional study involving 183 patients with CIEDs with atrial pacing capability. The oxidative stress and mitochondrial function were determined in peripheral blood mononuclear cells (PBMCs). Among 183 patients, 55.7% had permanent pacemakers, 7.7% had defibrillators, and 36.6% had cardiac resynchronization therapy. Mean age was 67.5 ± 14.7 yr with 51% being male. Mean left ventricular ejection fraction (LVEF) was 53.9 ± 16.8%. We demonstrated that the presence of atrial pacing above 50% correlated with higher levels of mitochondrial spared respiratory capacity (P = 0.043) and coupling efficiency (P = 0.045). After adjusting with multiple linear regression for age, sex, LVEF, history of AF, sick sinus syndrome, comorbidities, estimated glomerular filtration rate (eGFR), cardiac resynchronization therapy (CRT), and percentage of ventricular pacing, our findings revealed a statistically significant association between a higher percentage of atrial pacing and increased spared respiratory capacity (ß, 0.217, P = 0.046), lower nonmitochondrial respiration (ß, -0.230; P = 0.023), and proton leak (ß, -0.247; P = 0.022). We demonstrated that atrial pacing enhances mitochondrial performance in PBMCs and left ventricular contractile performance in patients with CIEDs. This observation may serve as an additional support for the preventive effect of atrial pacing in the prevention of atrial arrhythmia.NEW & NOTEWORTHY Atrial pacing enhances mitochondrial spare respiratory capacity and reduces proton leak. This finding may provide further evidence supporting the preventive role of atrial pacing in reducing the risk of atrial fibrillation in patients with cardiac implantable electronic devices.
Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Leucocitos Mononucleares , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Estudios Transversales , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico , Leucocitos Mononucleares/metabolismo , Marcapaso Artificial , Anciano de 80 o más Años , Estrés Oxidativo , Estimulación Cardíaca Artificial , Mitocondrias Cardíacas/metabolismo , Función Ventricular Izquierda , Terapia de Resincronización Cardíaca , Atrios Cardíacos/fisiopatología , Mitocondrias/metabolismoRESUMEN
INTRODUCTION: Data on implants of cardiac pacing systems in Spain in 2023 are presented. METHODS: The registry is based on the information provided by centers to the recording platform of the Heart Rhythm Association after device implantations, through Cardiodispositivos, the online platform of the National Registry. Other information sources include: a) data transfers from the manufacturing and marketing industry; b) the European pacemaker patient card; and c) local databases submitted by the implanting centers. RESULTS: In 2023, 112 hospitals participated in the registry (30 more than in 2022). A total of 24 343 device implantations were reported (48.1% more than in 2022) compared with 45 120 reported by Eucomed (European Confederation of Medical Suppliers Associations). Of these, 1646 were cardiac resynchronization therapy pacemakers. The devices showing the largest increases were leadless pacemakers, with 963 devices implanted, representing an 18.1% increase over 2022. The most frequent indication was atrioventricular block followed, for the first time, by atrial tachyarrhythmia with slow ventricular response. The number of devices included in remote monitoring also increased (cardiac resynchronization therapy defibrillators, 71%; cardiac resynchronization therapy pacemakers, 63%; and conventional pacemakers, 28%), although more moderately. CONCLUSIONS: In 2023, there was an increase in the number of institutions participating in the registry. The reporting of device implantations rose by 48.1%, and the implantation of leadless pacemakers grew by 18.1%. Remote monitoring also experienced modest growth compared with previous years.
Asunto(s)
Arritmias Cardíacas , Cardiología , Marcapaso Artificial , Sistema de Registros , Sociedades Médicas , Humanos , España , Marcapaso Artificial/estadística & datos numéricos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/epidemiología , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Masculino , FemeninoRESUMEN
BACKGROUND: Reducing anxiety about motor vehicle driving in patients receiving implantable cardioverter defibrillators and cardiac resynchronization therapy with defibrillators is important not only for improving quality of life but also for preventing vehicle collisions owing to driver distraction. This study aimed to clarify the driving-related anxiety of patients with these defibrillators and the factors that predict such anxiety. METHODS: We conducted a cross-sectional survey using a self-administered questionnaire of patients who had been driving a vehicle after device implantation at a general hospital between August 2018 and November 2019. RESULTS: The mean age was 60.8 ± 12.6 years. The reasons for implantation were primary prevention in 47 patients and secondary prevention in 30 patients. A total of 16 patients experienced anxiety about driving and 61 did not. Significantly more younger patients (mean age of 50.4 vs. 63.6 years, p < 0.001) and those with implantable cardioverter defibrillators had anxiety (100% vs. 73.8%, p = 0.02). Multivariable analysis indicated that age was the only independent factor that predicted driving-related anxiety (odds ratio, 0.937; 95% confidence interval, 0.883-0.993). CONCLUSIONS: Identifying and addressing driving-related anxiety in patients (particularly young patients) with defibrillators is important in preventing motor vehicle collisions and improving quality of life.
Asunto(s)
Ansiedad , Conducción de Automóvil , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Transversales , Conducción de Automóvil/psicología , Ansiedad/prevención & control , Ansiedad/terapia , Terapia de Resincronización Cardíaca/métodos , Encuestas y Cuestionarios , Calidad de Vida/psicología , AncianoRESUMEN
Heart failure and chronic kidney disease are common and clinically important conditions that regularly coexist. Electrophysiologic changes of advanced heart failure often result in abnormal conduction, causing dyssynchronous contraction, and development of ventricular arrhythmias, which can lead to sudden cardiac arrest. In the last 2 decades, implantable cardioverter-defibrillator and cardiac resynchronization therapy devices have been developed to address these complications. However, when the coexisting chronic kidney disease is advanced, the associated pathophysiologic cardiovascular changes can alter the efficacy and safety of those interventions and complicate the management. This review explores the impact of comorbid advanced heart failure and advanced chronic kidney disease on the efficacy and safety of implantable cardioverter-defibrillator and cardiac resynchronization therapy, the currently available evidence, and potential future directions.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Insuficiencia Renal Crónica , Humanos , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Renal Crónica/terapia , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Despite optimal medical therapy and cardiac resynchronization therapy (CRT), significant functional mitral regurgitation (MR) persisted in 30% of the patients and labeled as CRT nonresponders. AIMS: We sought to study the impact of transcatheter edge-to-edge repair (TEER) in patients with symptomatic grade III and IV functional MR despite CRT. METHODS: A retrospective analysis was conducted of all patients who had prior CRT for at least 6 months and underwent TEER for significant residual functional MR (grade ≥3) and symptomatic heart failure (HF) at our institution. The primary outcomes were the change in New York Heart Association classification (NYHA), MR grade, echo parameters, and NT-ProBNP from baseline to 1-year post-procedure. RESULTS: A total of 28 patients were identified, mean age of 73 ± 6.7 years and 89% males. Procedure success was achieved in all patients. At 1-year follow-up, patients had lower MR grade (median 2, IQR 1 [1,2] vs. 4, IQR 1 [3,4]; p < 0.001), NYHA class (median 2, IQR 1 [2,3] vs. 3, IQR 1 [3,4]; p < 0.001), and NT-ProBNP (7658 ± 11322 vs. 3760 ± 4431; p = 0.035) compared to before the TEER procedure. The left ventricular end-diastolic volume (255 ± 59 vs. 244 ± 66 mm; p = 0.016) and the right ventricular systolic pressure (52 ± 14 mmHg vs. 37 ± 13 mmHg, <0.001) decreased. CONCLUSION: Patients who remain symptomatic after CRT with severe functional MR had improved functional status and MR grade at 1-year following TEER. There was a signal toward reverse remodeling.
Asunto(s)
Cateterismo Cardíaco , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Válvula Mitral , Péptido Natriurético Encefálico , Recuperación de la Función , Función Ventricular Izquierda , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/terapia , Masculino , Femenino , Estudios Retrospectivos , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Factores de Tiempo , Cateterismo Cardíaco/efectos adversos , Anciano de 80 o más Años , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Remodelación Ventricular , Insuficiencia del Tratamiento , Resultado del TratamientoRESUMEN
The benefits of a cardiac resynchronization therapy (CRT) implantation are known in severe heart failure and its implantation may also be considered during pregnancy to ensure safe pregnancy and delivery for both the mother and the fetus. This study on a patient case aimed to estimate the absorbed dose (AD) to the fetus during the CRT implantation of 21st week of the pregnant woman. AD measurement was done using anthropomorphic phantom, radiophotoluminescence dosemeters and Monte Carlo simulation utilizing kerma area product (KAP) of the procedures. The measured AD for a phantom's uterus and heart was 0.116 and 14.7 mGy with total KAP of 27.9 Gycm2. The estimated actual AD to the fetus and the mother's heart was 0.004 and 1.2 mGy, with total KAP of 1.5 Gycm2. The dose to the fetus can be minimized with the optimized procedure.
Asunto(s)
Feto , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Humanos , Femenino , Embarazo , Feto/efectos de la radiación , Adulto , Marcapaso Artificial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Cardiac resynchronization therapy (CRT) improves ventricular function, but a positive response to CRT is often limited due to left ventricular (LV) lead placement in a suboptimal position. Complex coronary venous anatomy can hinder the placement of an LV lead in the target vessel, leading to poor CRT response. OBJECTIVE: To report experience with snare-assisted LV lead delivery in CRT and compare outcomes with the conventional LV lead delivery. METHODS: This is a single-center retrospective case-control study of CRT implants between 2016 and 2021. Snare-assisted lead delivery was performed in cases where conventional lead placement failed or when a preferred target vessel had anatomy amenable to the technique. Safety and outcomes were compared to conventional LV lead placement cases. RESULTS: Among 180 CRT cases, 33 were snare-assisted, and 147 were conventional LV lead placements. Median follow-up was 924 days in the snare and 618.5 days in the control group. The lead placement was successful in 28/33 snare and 138/147 control cases. A mid-vessel segment was attained in 89.3% of snare and 72.5% of control cases(p = .03). The apical position was more frequently observed in the control group (26.8% vs. 7.1%, p = .03). All-cause mortality trended lower in the snare group (6.1%) compared to (17.1%) in the control group (p = .13). CONCLUSION: Snare-assisted LV lead delivery is a safe and effective technique that can be utilized for overcoming complex venous anatomy.
Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Estudios de Casos y Controles , Terapia de Resincronización Cardíaca/métodos , Ventrículos Cardíacos , Implantación de Prótesis/métodos , Persona de Mediana Edad , Electrodos Implantados , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Biventricular pacing (BVP) appears to confer more pronounced advantages in women, yet the impact of conduction system pacing (CSP) remains insufficiently characterized. This investigation seeks to elucidate sex-specific disparities in clinical outcomes among patients with typical left bundle branch block (LBBB) undergoing CSP, with a particular focus on assessing contributory factors. METHODS: Consecutive patients diagnosed with nonischemic cardiomyopathy, exhibiting left ventricular ejection fraction (LVEF) ≤ 40%, and manifesting typical LBBB as Strauss criteria, underwent CSP. Subsequent longitudinal monitoring assessed improvements in LVEF and the composite endpoint of mortality or heart failure hospitalization (HFH). RESULTS: Among the included 176 patients, women (n = 84, mean age: 69.5 ± 8.8 years) displayed smaller heart size (LVEDd, 62.0 ± 8.3 mm vs. 64.8 ± 7.9 mm, P = 0.023) and shorter baseline QRSd (163.5 ± 17.7 ms vs. 169.7 ± 15.1 ms; P = 0.013) than men. Of the 171 patients who completed the follow-up, super-response was observed in 120 (70%), with a higher occurrence in women than men (78.3% vs. 62.5%, P = 0.024). The incidence of death or HFH was numerically lower in women (7.1% Vs 13%, Log-rank P = 0.216). Notably, the super-response showed a significant difference in women compared to men at the same electrocardiography and/or echocardiographic parameters value. Mediation analysis between sex and super-response revealed that LVEDd and pQRSd play an intermediary role, with the mediation proportion of 26.07% and 27.98%, respectively. CONCLUSIONS: Women may derive more benefits from CSP, and pQRSd and LVEDd partly drive this difference.
Asunto(s)
Bloqueo de Rama , Humanos , Femenino , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Masculino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Terapia de Resincronización Cardíaca/métodos , Estudios de Seguimiento , Caracteres Sexuales , Factores Sexuales , Sistema de Conducción Cardíaco/fisiopatología , Electrocardiografía , Estudios RetrospectivosRESUMEN
PURPOSE: Suboptimal response to cardiac resynchronization therapy (CRT) may be improved by optimization of device parameters using echocardiography. For this purpose, the aortic velocity-time integral (aVTI) has been used as a target metric to define optimal velocity timings for each ventricle. dP/dt is a parameter used for the assessment of myocardial contractility. In this study, we aimed to evaluate the effectiveness of Doppler-derived dP/dt in optimization by assessing the possible correlation between aVTI and dP/dt. METHODS: Patients with CRT admitted for routine follow-up were included in the study. Aortic VTI and dP/dt measurements were recorded in four different standard pacing configurations during reprogramming. RESULTS: A total of 45 patients were included in the final analysis. No correlation was found between the aVTI and the delta dP/dt value in the two configurations where the change in dP/dt was maximum (p = 0.894). In the two configurations where the change in aVTI was maximum, there was also no correlation between the delta dP/dt and the delta aVTI (p = 0.715). When patients were dichotomized according to the median value of dP/dt, there were no differences in aVTI, NYHA classes, LVEF, and mitral regurgitation (MR) severity (p = 0.4; p = 0.5; p = 0.7; p = 0.3; respectively). The change in both dP/dt and aVTI was statistically significant when switching from RV-only to QRS width-targeted configuration (p = 0.001; p = 0.041; respectively). CONCLUSION: In conclusion, aVTI recorded at different pacing configurations did not correlate with dP/dt during interventricular optimization. However, both parameters consistently showed a positive effect of biventricular pacing on contractile synchronization and stroke volume.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Contracción Miocárdica , Valor Predictivo de las Pruebas , Función Ventricular Izquierda , Humanos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico por imagen , Factores de Tiempo , Reproducibilidad de los Resultados , Ecocardiografía Doppler , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Dispositivos de Terapia de Resincronización Cardíaca , Recuperación de la Función , Ecocardiografía Doppler de Pulso , Frecuencia CardíacaRESUMEN
BACKGROUND: The fibrosis-5 (FIB-5) index is a noninvasive marker for assessing the progression of liver fibrosis and predictor in patients with heart failure (HF). This study investigated the association between the FIB-5 index and response to cardiac resynchronization therapy (CRT) and evaluated its predictive value for prognosis. METHODS: In total, 203 patients who underwent CRT/CRT-defibrillator (CRT-D) implantation were retrospectively included. The FIB-5 index was calculated using blood samples obtained before and after CRT/CRT-D. Response to CRT was defined as a relative reduction in left ventricular end-systolic volume of ≥15% 6 months after CRT/CRT-D. We compared the prognosis after CRT/CRT-D between the groups according to the FIB-5 index. RESULTS: One hundred and twenty-three patients (61%) responded to CRT. The responder group demonstrated a significantly higher FIB-5 index than the nonresponder group (-2.76 ± 3.85 vs. -4.67 ± 3.29, p < 0.001). Receiver-operating characteristic analysis demonstrated that the area under the curve of the FIB-5 index was 0.660 with a cutoff value of -4.00 for responders. In multivariate analysis, FIB-5 index ≥ -4.00 was an independent predictor for CRT response (odds ratio: 3.665, p = 0.003), in addition to QRS duration ≥ 150 ms and echocardiographic dysynchrony. The FIB-5 index increased significantly after 6 months in the responder group but not in the nonresponder group. The FIB-5 index ≥ -4.00 group showed a significantly better prognosis for cardiac death, HF hospitalization, and composite endpoint than the FIB-5 index < -4.00 group. CONCLUSION: The FIB-5 index in addition to classical predictors may be a useful marker for predicting response to CRT.
Asunto(s)
Biomarcadores , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Cirrosis Hepática , Humanos , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/sangre , Cirrosis Hepática/terapia , Cirrosis Hepática/sangre , Cirrosis Hepática/fisiopatología , Cirrosis Hepática/complicaciones , Pronóstico , Estudios Retrospectivos , Biomarcadores/sangre , Anciano , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Resultado del TratamientoRESUMEN
AIM: To evaluate the efficacy of cardiac resynchronization therapy (CRT) in patients with chronic heart failure (CHF) associated with cardiac dyssynchrony and to identify the factors that influence the CRT efficacy. MATERIAL AND METHODS: This retrospective study included 155 patients after implantation of CRT devices. The CRT devices with a built-in cardioverter-defibrillator (CRT-D) and without it (CRT-P) were implanted in 139 (89.7%) and 16 (10.3%) patients, respectively. The follow-up period was 52.37±35.94 months. Based on the study results, two groups of patients were formed depending on the presence of a clinical response to CRT, responders and non-responders. The factors that influenced the clinical response to CRT were studied. The effect of the baseline state of patients on the effect of therapy was assessed. The need for CRT optimization and a possibility of using electrocardiographic criteria for that purpose were studied. Modern devices and leads for CRT, their functional capabilities and their influence on the CRT efficacy were characterized. Statistical analysis was performed with an IBM SPSS Statistics 21.0 (Chicago, USA) package. RESULTS: CRT implantation with the left ventricular lead placement according to the traditional technique, through the coronary sinus, was successful in 130 (87.9%) patients. Difficulties with the left ventricular lead placement were noted in 13 (8.3%) patients when other techniques were used. After 6 months, a hemodynamic and clinical response was observed in 112 (72.2%) patients, and no positive response in 43 (27.8%). The increase in left ventricular ejection fraction in the responder group was more than 21.8±3.7%, which was associated with an improvement of the 6-minute walk test results. Th clinical response was significantly influenced by the possibility of stimulation from the basal parts of the heart; the use of more modern devices for CRT and quadripolar left ventricular leads; timely CRT optimization; and persistent dyssynchrony in non-responders. During the follow-up period, 34 (21.9%) patients died. The death rate in the non-responder group was significantly higher than in the responder group, 18 (41.3%) vs. 16 (14.3%), p=0.001. The main cause of death in the group of non-responders was CHF. Heart transplantation was performed in 3 (1.9%) patients. CONCLUSION: CRT increases the life span and improves the quality of life in patients with CHF and cardiac dyssynchrony. There was a group of patients with no benefit from CRT in this study. Modern devices allow increasing the number of patients who benefit from CRT. Periodic optimization of CRT is necessary. When optimizing CRT, it is possible to use electrocardiographic criteria of effectiveness: duration of the QRS complex and changes in the position of the electrical axis of the heart.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Enfermedad Crónica , ElectrocardiografíaRESUMEN
The impact of age (≥ 85 vs < 85 years) on clinical outcomes and pacemaker performance of conduction system pacing (CSP) compared to right ventricular pacing (RVP) were examined. Consecutive patients from a prospective, observational, multicenter study with pacemakers implanted for bradycardia were studied. The primary endpoint was a composite of heart failure (HF)-hospitalizations, pacing-induced cardiomyopathy requiring cardiac resynchronization therapy or all-cause mortality. Secondary endpoints were acutely successful CSP, absence of pacing-complications, optimal pacemaker performance defined as pacing thresholds < 2.5 V, R-wave amplitude ≥ 5 V and absence of complications, threshold stability (no increases of > 1 V) and persistence of His-Purkinje capture on follow-up. Among 984 patients (age 74.1 ± 11.2 years, 41% CSP, 16% ≥ 85 years), CSP was independently associated with reduced hazard of the primary endpoint compared to RVP, regardless of age-group (< 85 years: adjusted hazard ratio [AHR] 0.63, 95% confidence interval [CI] 0.40-0.98; ≥ 85 years: AHR 0.40, 95% CI 0.17-0.94). Among patients with CSP, age did not significantly impact the secondary endpoints of acute CSP success (86% vs 88%), pacing complications (19% vs 11%), optimal pacemaker performance (64% vs 69%), threshold stability (96% vs 96%) and persistent His-Purkinje capture (86% vs 91%) on follow-up (all p > 0.05). CSP improves clinical outcomes in all age-groups, without compromising procedural safety or pacemaker performance in the very elderly.
Asunto(s)
Bradicardia , Humanos , Anciano de 80 o más Años , Anciano , Masculino , Femenino , Bradicardia/terapia , Estudios Prospectivos , Resultado del Tratamiento , Estudios de Factibilidad , Estimulación Cardíaca Artificial/métodos , Estimulación Cardíaca Artificial/efectos adversos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Marcapaso Artificial , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/efectos adversosRESUMEN
Severe systemic right ventricular failure with tricuspid regurgitation is associated with poor prognosis. Here, we report a case of 49-year-old patient who experienced severe systemic right ventricular failure following atrial switch. We chose the surgical strategy for this challenging case using comprehensive four-dimensional imaging. The patient underwent tricuspid valve repair and cardiac resynchronization therapy and recovered with improved cardiac function and regulated tricuspid valve regurgitation.