Development and validation of an instrument (CSII - Brazil) to assess users' conceptual and procedural knowledge of continuous subcutaneous infusion systems
Arch. endocrinol. metab. (Online)
; 65(1): 67-78, Jan.-Feb. 2021. tab, graf
Article
en En
| LILACS
| ID: biblio-1152882
Biblioteca responsable:
BR1.1
ABSTRACT
ABSTRACT Objective:
To develop, adapt and validate an instrument named "CSII - Brazil" to assess users' conceptual and procedural knowledge of continuous subcutaneous insulin infusion systems. Materials andmethods:
Methodological and exploratory study developed in three stages a) instrument development; b) content validation and cultural adaptation (evaluation by a committee of experts and pre-test with CSII users); c) psychometric validation through instrument application in a sample of 60 patients by means of the web tool e-Surv. Internal consistency and reproducibility analyses were performed within IBM SPSS Statistics 20 programming environment.Results:
The 16 multiple-choice question instrument successfully attained a content validity index of 0.97, showing satisfactory internal consistency, with 0.61 Cronbach's alpha [95% CI 0.462-0.746] and an intraclass correlation coefficient of 0.869 [95% CI 0.789-0.919] between the test and retest scores.Conclusion:
The CSII - Brazil instrument is considered adequate and validated to assess continuous subcutaneous infusion system users' conceptual and procedural knowledge.Palabras clave
Texto completo:
1
Base de datos:
LILACS
Asunto principal:
Sistemas de Infusión de Insulina
/
Infusiones Subcutáneas
/
Insulina
Límite:
Humans
País/Región como asunto:
America do sul
/
Brasil
Idioma:
En
Revista:
Arch Endocrinol Metab
/
Arch. endocrinol. metab. (Online)
/
Archives of endocrinology and metabolism (Impresso)
/
Archives of endocrinology and metabolism (Online)
Asunto de la revista:
ENDOCRINOLOGIA
/
METABOLISMO
Año:
2021
Tipo del documento:
Article
País de afiliación:
Brasil