Your browser doesn't support javascript.
loading
Metal release from simulated fixed orthodontic appliances.
Hwang, C J; Shin, J S; Cha, J Y.
Afiliación
  • Hwang CJ; Department of Orthodontics, College of Dentistry, Yonsei University, Seoul, Korea. hwang@yumc.yonsei.ac.kr
Am J Orthod Dentofacial Orthop ; 120(4): 383-91, 2001 Oct.
Article en En | MEDLINE | ID: mdl-11606963
ABSTRACT
Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 +/- 0.15, 37 degrees C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 x .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco's copper NiTi and Tomy's Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500 degrees C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.
Asunto(s)
Buscar en Google
Base de datos: MEDLINE Asunto principal: Aparatos Ortodóncicos / Acero Inoxidable / Titanio / Metales / Níquel Tipo de estudio: Prognostic_studies Idioma: En Revista: Am J Orthod Dentofacial Orthop Asunto de la revista: ODONTOLOGIA / ORTODONTIA Año: 2001 Tipo del documento: Article
Buscar en Google
Base de datos: MEDLINE Asunto principal: Aparatos Ortodóncicos / Acero Inoxidable / Titanio / Metales / Níquel Tipo de estudio: Prognostic_studies Idioma: En Revista: Am J Orthod Dentofacial Orthop Asunto de la revista: ODONTOLOGIA / ORTODONTIA Año: 2001 Tipo del documento: Article