ABSTRACT
The objective of this study was to evaluate the bone ingrowth of a new vacuum plasma sprayed titanium surface (vps-ti) in comparison to cs-titanium implants in a göttinger minipig model. Fifteen göttinger minipigs each received the two implants, vacuum plasma sprayed titanium with a porosity of 50% and a pore size of 200 microm (vps-ti) and an implant with a similar porosity but a different pore size 500 microm (cs-ti), at the proximal femur metaphysis by press-fit technique. The pigs were euthanized at three different postsurgical periods 4, 8 and 12 weeks. Each femur was harvested and qualitative (macroscopic and microscopic) and quantitative (histomorphometric) histological analysis was done on histological slides. The results indicated that there was a difference in bone ingrowth between the two implants, whereas the bone ingrowth of vps-ti was superior to cs-ti after 4 and 8 weeks healing time. 12 weeks post implantationem no statistiscal difference was evident. The pore size of 200 microm seemed superior to a pore size of 500 microm. Whether or not these effects lead to a better mechanical stability remains unanswered.
Asunto(s)
Buscar en Google
Base de datos: MEDLINE Asunto principal: Titanio / Interpretación de Imagen Asistida por Computador / Oseointegración / Análisis de Falla de Equipo / Fémur / Prótesis de Cadera Tipo de estudio: Evaluation_studies / Qualitative_research Límite: Animals Idioma: De Revista: Biomed Tech (Berl) Año: 2005 Tipo del documento: Article
Buscar en Google
Base de datos: MEDLINE Asunto principal: Titanio / Interpretación de Imagen Asistida por Computador / Oseointegración / Análisis de Falla de Equipo / Fémur / Prótesis de Cadera Tipo de estudio: Evaluation_studies / Qualitative_research Límite: Animals Idioma: De Revista: Biomed Tech (Berl) Año: 2005 Tipo del documento: Article