Semiautomatic segmentation of ventilated airspaces in healthy and asthmatic subjects using hyperpolarized 3He MRI.
Lui, J K; LaPrad, A S; Parameswaran, H; Sun, Y; Albert, M S; Lutchen, K R.
Afiliación
  • Lui JK; Boston University, School of Medicine, Boston, MA 02118, USA.
Comput Math Methods Med ; 2013: 624683, 2013.
Article en En | MEDLINE | ID: mdl-23606904
ABSTRACT
A segmentation algorithm to isolate areas of ventilation from hyperpolarized helium-3 magnetic resonance imaging (HP (3)He MRI) is described. The algorithm was tested with HP (3)He MRI data from four healthy and six asthmatic subjects. Ventilated lung volume (VLV) measured using our semiautomated technique was compared to that obtained from manual outlining of ventilated lung regions and to standard spirometric measurements. VLVs from both approaches were highly correlated (R = 0.99; P < 0.0001) with a mean difference of 3.8 mL and 95% agreement indices of -30.8 mL and 38.4 mL. There was no significant difference between the VLVs obtained through the semiautomatic approach and the manual approach. A Dice coefficient which quantified the intersection of the two datasets was calculated and ranged from 0.95 to 0.97 with a mean of 0.96 ± 0.01 (mean ± SD). VLVs obtained through the semiautomatic algorithm were also highly correlated with measurements of forced expiratory volume in one second (FEV1) (R = 0.82; P = 0.0035) and forced vital capacity (FVC) (R = 0.95; P < 0.0001). The technique may open new pathways toward advancing more quantitative characterization of ventilation for routine clinical assessment for asthma severity as well as a number of other respiratory diseases.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Asma / Imagen por Resonancia Magnética Tipo de estudio: Guideline / Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Comput Math Methods Med Asunto de la revista: INFORMATICA MEDICA Año: 2013 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Asma / Imagen por Resonancia Magnética Tipo de estudio: Guideline / Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Comput Math Methods Med Asunto de la revista: INFORMATICA MEDICA Año: 2013 Tipo del documento: Article País de afiliación: Estados Unidos