Your browser doesn't support javascript.
loading
Radiological assessment of breast density by visual classification (BI-RADS) compared to automated volumetric digital software (Quantra): implications for clinical practice.
Regini, Elisa; Mariscotti, Giovanna; Durando, Manuela; Ghione, Gianluca; Luparia, Andrea; Campanino, Pier Paolo; Bianchi, Caterina Chiara; Bergamasco, Laura; Fonio, Paolo; Gandini, Giovanni.
Afiliación
  • Regini E; S.C. Radiologia Universitaria, Università di Torino, Dipartimento di Diagnostica per Immagini e Radioterapia, Azienda Ospedaliero-Universitaria Città della Salute e della Scienza di Torino, Via Genova 3, 10126, Turin, Italy, elisa.regini@libero.it.
Radiol Med ; 119(10): 741-9, 2014 Oct.
Article en En | MEDLINE | ID: mdl-24610166
ABSTRACT

OBJECTIVE:

This study was done to assess breast density on digital mammography and digital breast tomosynthesis according to the visual Breast Imaging Reporting and Data System (BI-RADS) classification, to compare visual assessment with Quantra software for automated density measurement, and to establish the role of the software in clinical practice. MATERIALS AND

METHODS:

We analysed 200 digital mammograms performed in 2D and 3D modality, 100 of which positive for breast cancer and 100 negative. Radiological density was assessed with the BI-RADS classification; a Quantra density cut-off value was sought on the 2D images only to discriminate between BI-RADS categories 1-2 and BI-RADS 3-4. Breast density was correlated with age, use of hormone therapy, and increased risk of disease.

RESULTS:

The agreement between the 2D and 3D assessments of BI-RADS density was high (K 0.96). A cut-off value of 21% is that which allows us to best discriminate between BI-RADS categories 1-2 and 3-4. Breast density was negatively correlated to age (r = -0.44) and positively to use of hormone therapy (p = 0.0004). Quantra density was higher in breasts with cancer than in healthy breasts.

CONCLUSIONS:

There is no clear difference between the visual assessments of density on 2D and 3D images. Use of the automated system requires the adoption of a cut-off value (set at 21%) to effectively discriminate BI-RADS 1-2 and 3-4, and could be useful in clinical practice.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Mama / Neoplasias de la Mama / Mamografía / Intensificación de Imagen Radiográfica Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies / Screening_studies Límite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Radiol Med Año: 2014 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Mama / Neoplasias de la Mama / Mamografía / Intensificación de Imagen Radiográfica Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies / Screening_studies Límite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Radiol Med Año: 2014 Tipo del documento: Article