Your browser doesn't support javascript.
loading
Change in drusen area over time compared using spectral-domain optical coherence tomography and color fundus imaging.
Gregori, Giovanni; Yehoshua, Zohar; Garcia Filho, Carlos Alexandre de Amorim; Sadda, SriniVas R; Portella Nunes, Renata; Feuer, William J; Rosenfeld, Philip J.
Afiliación
  • Gregori G; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
  • Yehoshua Z; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
  • Garcia Filho CA; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
  • Sadda SR; Doheny Eye Institute, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, California, United States.
  • Portella Nunes R; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
  • Feuer WJ; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
  • Rosenfeld PJ; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.
Invest Ophthalmol Vis Sci ; 55(11): 7662-8, 2014 Oct 21.
Article en En | MEDLINE | ID: mdl-25335982
ABSTRACT

PURPOSE:

To investigate the relationship between drusen areas measured with color fundus images (CFIs) and those with spectral-domain optical coherence tomography (SDOCT).

METHODS:

Forty-two eyes from thirty patients with drusen in the absence of geographic atrophy were recruited to a prospective study. Digital color fundus images and SDOCT images were obtained at baseline and at follow-up visits at 3 and 6 months. Registered, matched circles centered on the fovea with diameters of 3 mm and 5 mm were identified on both CFIs and SDOCT images. Spectral-domain OCT drusen measurements were obtained using a commercially available proprietary algorithm. Drusen boundaries on CFIs were traced manually at the Doheny Eye Institute Image Reading Center.

RESULTS:

Mean square root drusen area (SQDA) measurements for the 3-mm circles on the SDOCT images were 1.451 mm at baseline and 1.464 mm at week 26, whereas the measurements on CFIs were 1.555 mm at baseline and 1.584 mm at week 26. Mean SQDA measurements from CFIs were larger than those from the SDOCT measurements at all time points (P = 0.004 at baseline, P = 0.003 at 26 weeks). Changes in SQDA over 26 weeks measured with SDOCT were not different from those measured with CFIs (mean difference = 0.014 mm, P = 0.5).

CONCLUSIONS:

Spectral-domain OCT drusen area measurements were smaller than the measurements obtained from CFIs. However, there were no differences in the change in drusen area over time between the two imaging modalities. Spectral-domain OCT measurements were considerably more sensitive in assessing drusen area changes.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diagnóstico por Imagen / Drusas Retinianas / Tomografía de Coherencia Óptica Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diagnóstico por Imagen / Drusas Retinianas / Tomografía de Coherencia Óptica Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos