Your browser doesn't support javascript.
loading
Edge profile measurements using Thomson scattering on the KSTAR tokamak.
Lee, J H; Oh, S; Lee, W R; Ko, W H; Kim, K P; Lee, K D; Jeon, Y M; Yoon, S W; Cho, K W; Narihara, K; Yamada, I; Yasuhara, R; Hatae, T; Yatsuka, E; Ono, T; Hong, J H.
Afiliación
  • Lee JH; National Fusion Research Institute, Daejeon, South Korea.
  • Oh S; National Fusion Research Institute, Daejeon, South Korea.
  • Lee WR; National Fusion Research Institute, Daejeon, South Korea.
  • Ko WH; National Fusion Research Institute, Daejeon, South Korea.
  • Kim KP; National Fusion Research Institute, Daejeon, South Korea.
  • Lee KD; National Fusion Research Institute, Daejeon, South Korea.
  • Jeon YM; National Fusion Research Institute, Daejeon, South Korea.
  • Yoon SW; National Fusion Research Institute, Daejeon, South Korea.
  • Cho KW; National Fusion Research Institute, Daejeon, South Korea.
  • Narihara K; National Institute for Fusion Science, Nagoya, Japan.
  • Yamada I; National Institute for Fusion Science, Nagoya, Japan.
  • Yasuhara R; National Institute for Fusion Science, Nagoya, Japan.
  • Hatae T; Japan Atomic Energy Agency, Naka, Japan.
  • Yatsuka E; Japan Atomic Energy Agency, Naka, Japan.
  • Ono T; Japan Atomic Energy Agency, Naka, Japan.
  • Hong JH; Department of Physics, KAIST, South Korea.
Rev Sci Instrum ; 85(11): 11D407, 2014 Nov.
Article en En | MEDLINE | ID: mdl-25430170
ABSTRACT
In the KSTAR Tokamak, a "Tangential Thomson Scattering" (TTS) diagnostic system has been designed and installed to measure electron density and temperature profiles. In the edge system, TTS has 12 optical fiber bundles to measure the edge profiles with 10-15 mm spatial resolution. These 12 optical fibers and their spatial resolution are not enough to measure the pedestal width with a high accuracy but allow observations of L-H transition or H-L transitions at the edge. For these measurements, the prototype ITER edge Thomson NdYAG laser system manufactured by JAEA in Japan is installed. In this paper, the KSTAR TTS system is briefly described and some TTS edge profiles are presented and compared against the KSTAR Charge Exchange Spectroscopy and other diagnostics. The future upgrade plan of the system is also discussed in this paper.

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Corea del Sur

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Corea del Sur