Laparoscopic management of primary pelvi-ureteric junction obstruction: Single-centre experience.
Nour, Hani; Mostafa, Ahmad; Gobashy, Samir; Elganzoury, Hossam; Elkholy, Amr; Riad, Essam.
Afiliación
  • Nour H; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
  • Mostafa A; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
  • Gobashy S; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
  • Elganzoury H; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
  • Elkholy A; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
  • Riad E; Urology Department, Theodor Bilharz Research Institute, Giza, Egypt.
Arab J Urol ; 9(4): 241-4, 2011 Dec.
Article en En | MEDLINE | ID: mdl-26579305
OBJECTIVE: To evaluate the effect and safety of laparoscopic pyeloplasty in the treatment of pelvi-ureteric junction obstruction (PUJO). PATIENTS AND METHODS: In 34 patients, laparoscopic dismembered pyeloplasty was used to treat primary PUJO. Information was obtained for symptoms, results of a nuclear scan before and after surgery, intraoperative blood loss, operative duration, stenting method, and hospital stay. Under general anaesthesia and in the flank position, a 10 mm trocar was first placed above the umbilicus; three 5 mm working ports were then placed. The ureter and pelvis were freed from surrounding adhesions. The obstructive pelvi-ureteric segment was then excised, and the opened point of the ureter spatulated. Ureteropyeloplasty between the lower pole, pelvis and spatulated ureter was made using a 4-0 polyglactin suture around a JJ stent. RESULTS: The mean (SD) preoperative nuclear scan result was 23.6 (6.4) mL/min, with retention of tracer. The median operative duration was 200 min, and the median blood loss 120 mL. All patients were stented with a JJ stent. The mean hospital stay was 5 days. The final results were assessed at 6 months after surgery, when the mean (SD) nuclear scan result was 30 (7.4) mL/min. CONCLUSION: Laparoscopic pyeloplasty is a safe and effective option which can produce satisfactory results both clinically and radiologically.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Arab J Urol Año: 2011 Tipo del documento: Article País de afiliación: Egipto