Your browser doesn't support javascript.
loading
[Determination of tin dioxide in workplace air by atomic fluorescence spectrometry after alkali fusion].
Liu, F; Yun, J P; Li, S F; Lin, Y R.
Afiliación
  • Liu F; Shenzhen Prevention and Treatment Center for Occupation Diseases, Shenzhen 518000, China.
Article en Zh | MEDLINE | ID: mdl-27014897
ABSTRACT

OBJECTIVE:

To establish the method of atomic fluorescence spectrometry (AFS) after alkali fusion for determination of tin dioxide in workplace air.

METHODS:

Tin dioxide in workplace air was collected with microporous membrane, directly digested by alkali fusion with solid sodium hydroxide heated by electric furnace, and determined by AFS.

RESULTS:

The linear range of tin dioxide (as Sn) determined by AFS was 1.5~100 µg/L (excluding zero) , and the correlation coefficient was 0.9993. The detection limit of this method was 0.5 µg/L, the lower limit of quantification was 1.5 µg/L, and the minimum detectable concentration was 0.05 mg/m(3) (the volume of the air sample was 75 L) . The relative standard deviation was 1.94%~3.55%, and the average recovery of standard addition was 95.0%~96.0%.

CONCLUSION:

The method of AFS after alkali fusion for determination of tin dioxide in workplace air is proved to be simple, rapid, sensitive, and accurate, with complete digestion.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Fluorescencia Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Fluorescencia Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Asunto de la revista: MEDICINA OCUPACIONAL Año: 2016 Tipo del documento: Article País de afiliación: China