Your browser doesn't support javascript.
loading
Efficient radiosynthesis and non-clinical safety tests of the TSPO radioprobe [(18)F]FEDAC: Prerequisites for clinical application.
Kawamura, Kazunori; Kumata, Katsushi; Takei, Makoto; Furutsuka, Kenji; Hashimoto, Hiroki; Ito, Takehito; Shiomi, Satoshi; Fujishiro, Tomoya; Watanabe, Ryuji; Igarashi, Nobuyuki; Muto, Masatoshi; Yamasaki, Tomoteru; Yui, Joji; Xie, Lin; Hatori, Akiko; Zhang, Yiding; Nemoto, Kazuyoshi; Fujibayashi, Yasuhisa; Zhang, Ming-Rong.
Afiliación
  • Kawamura K; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan. Electronic address: kawamura.kazunori@qst.go.jp.
  • Kumata K; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Takei M; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Furutsuka K; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; SHI Accelerator Service Ltd., Tokyo 141-0032, Japan.
  • Hashimoto H; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Ito T; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; SHI Accelerator Service Ltd., Tokyo 141-0032, Japan.
  • Shiomi S; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; Tokyo Nuclear Services, Tokyo 110-0016, Japan.
  • Fujishiro T; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; Tokyo Nuclear Services, Tokyo 110-0016, Japan.
  • Watanabe R; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; Tokyo Nuclear Services, Tokyo 110-0016, Japan.
  • Igarashi N; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; Tokyo Nuclear Services, Tokyo 110-0016, Japan.
  • Muto M; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan; Tokyo Nuclear Services, Tokyo 110-0016, Japan.
  • Yamasaki T; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Yui J; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Xie L; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Hatori A; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Zhang Y; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Nemoto K; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Fujibayashi Y; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
  • Zhang MR; Department of Radiopharmaceuticals Development, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba 263-8555, Japan.
Nucl Med Biol ; 43(7): 445-53, 2016 07.
Article en En | MEDLINE | ID: mdl-27183465
ABSTRACT

INTRODUCTION:

[(18)F]FEDAC ([(18)F]1) has potent binding affinity and selectivity for translocator protein (18kDa, TSPO), and has been used to noninvasively visualize neuroinflammation, lung inflammation, acute liver damage, nonalcoholic fatty liver disease, and liver fibrosis. We had previously synthesized [(18)F]1 in two

steps:

(i) preparation of [(18)F]fluoroethyl bromide and (ii) coupling of [(18)F]fluoroethyl bromide with the appropriate precursor (2) for labeling. In this study, to clinically utilize [(18)F]1 as a PET radiopharmaceutical and to transfer the production technique of [(18)F]1 to other PET centers, we simplified its preparation by using a direct, one-step, tosyloxy-for-fluorine substitution. We also performed an acute toxicity study as a major non-clinical safety test, and determined radiometabolites using human liver microsomes.

METHODS:

[(18)F]1 was prepared via direct (18)F-fluorination by heating the corresponding tosylated derivative (3) with [(18)F]fluoride as its Kryptofix 222 complex in dimethyl sulfoxide at 110°C for 15min, following by HPLC purification. Non-clinical safety tests were performed for the extended single-dose toxicity study in rats, and for the in vitro metabolite analysis with human liver microsomal incubation.

RESULTS:

High quality batches of [(18)F]1, compatible with clinical applications, were obtained. At the end of irradiation, the decay-corrected radiochemical yield of [(18)F]1 using 1 and 5mg of precursor based on [(18)F]fluoride was 18.5±7.9% (n=10) and 52.0±5.8% (n=3), respectively. A single-dose of [(18)F]1 did not show toxicological effects for 14 days after the injection in male and female rats. In human liver microsomal incubations, [(18)F]1 was easily metabolized to [(18)F]desbenzyl-FEDAC ([(18)F]10) by CYPs (4.2% of parent compound left 60min after incubation).

CONCLUSION:

We successfully synthesized clinical grade batches of [(18)F]1 and verified the absence of innocuity of this radiotracer. [(18)F]1 will be used to first-in-human studies in our facility.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Purinas / Seguridad / Proteínas Portadoras / Receptores de GABA-A / Acetamidas Límite: Animals / Humans Idioma: En Revista: Nucl Med Biol Asunto de la revista: BIOLOGIA / MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Purinas / Seguridad / Proteínas Portadoras / Receptores de GABA-A / Acetamidas Límite: Animals / Humans Idioma: En Revista: Nucl Med Biol Asunto de la revista: BIOLOGIA / MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article