Your browser doesn't support javascript.
loading
Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.
Frydrychowicz, A; Roldan-Alzate, A; Winslow, E; Consigny, D; Campo, C A; Motosugi, U; Johnson, K M; Wieben, O; Reeder, S B.
Afiliación
  • Frydrychowicz A; Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI, 53792-3252, USA. alex.frydrychowicz@uksh.de.
  • Roldan-Alzate A; Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany. alex.frydrychowicz@uksh.de.
  • Winslow E; University of Lübeck, Lübeck, Germany. alex.frydrychowicz@uksh.de.
  • Consigny D; Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI, 53792-3252, USA.
  • Campo CA; Department of Mechanical Engineering, University of Wisconsin, Madison, USA.
  • Motosugi U; Department of Surgery, University of Wisconsin, Madison, USA.
  • Johnson KM; Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI, 53792-3252, USA.
  • Wieben O; Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI, 53792-3252, USA.
  • Reeder SB; Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI, 53792-3252, USA.
Eur Radiol ; 27(12): 5316-5324, 2017 Dec.
Article en En | MEDLINE | ID: mdl-28656461

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Vena Porta / Velocidad del Flujo Sanguíneo / Ultrasonografía / Angiografía por Resonancia Magnética / Hipertensión Portal / Circulación Hepática Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Vena Porta / Velocidad del Flujo Sanguíneo / Ultrasonografía / Angiografía por Resonancia Magnética / Hipertensión Portal / Circulación Hepática Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos