Your browser doesn't support javascript.
loading
Evaluation of a Novel Cryoprobe for Atrial Ablation in a Chronic Ovine Model.
Schill, Matthew R; Melby, Spencer J; Speltz, Molly; Breitbach, May; Schuessler, Richard B; Damiano, Ralph J.
Afiliación
  • Schill MR; Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Melby SJ; Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Speltz M; Scientific Solutions, LLC, Fridley, Minnesota.
  • Breitbach M; Department of Surgery, Experimental Surgical Services, University of Minnesota, Minneapolis, Minnesota.
  • Schuessler RB; Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Damiano RJ; Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, Missouri. Electronic address: damianor@wustl.edu.
Ann Thorac Surg ; 104(3): 1069-1073, 2017 Sep.
Article en En | MEDLINE | ID: mdl-28838486
PURPOSE: Cryoablation is used in the treatment of atrial fibrillation and other cardiac arrhythmias. This study evaluated a novel 10-cm flexible nitrous oxide cryoprobe in an ovine model of atrial ablation. DESCRIPTION: Six sheep were anesthetized, underwent a left thoracotomy, and were placed on cardiopulmonary bypass. A left atriotomy was performed, and the cryoprobe was applied endocardially for 120 seconds at less than -40°C to 4 sites on the left atrium. The atrium was closed and the animals were allowed to recover. After 30 days, the animals were euthanized. Transmurality was evaluated in 5-mm sections of each lesion using 2,3,5-triphenyltetrazolium chloride (TTC) and Masson's trichrome staining. EVALUATION: All animals survived. One hundred four of 106 sections (98%) were transmural by TTC; 103 of 106 (97%) sections were transmural by trichrome staining. There was no late atrial perforation, intraluminal thrombus, or thromboembolism. CONCLUSIONS: The device reliably produced transmural lesions in a chronic ovine model. Its performance was equivalent to that of other nitrous oxide cryoablation systems.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Criocirugía / Sistema de Conducción Cardíaco Límite: Animals Idioma: En Revista: Ann Thorac Surg Año: 2017 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Criocirugía / Sistema de Conducción Cardíaco Límite: Animals Idioma: En Revista: Ann Thorac Surg Año: 2017 Tipo del documento: Article