Your browser doesn't support javascript.
loading
Laryngeal Mask Airway for Surfactant Administration in Neonates: A Randomized, Controlled Trial.
Roberts, Kari D; Brown, Roland; Lampland, Andrea L; Leone, Tina A; Rudser, Kyle D; Finer, Neil N; Rich, Wade D; Merritt, T Allen; Czynski, Adam J; Kessel, Julie M; Tipnis, Sajani M; Stepka, Erin C; Mammel, Mark C.
Afiliación
  • Roberts KD; Department of Pediatrics, University of Minnesota, Minneapolis, MN. Electronic address: rober694@umn.edu.
  • Brown R; Department of Biostatistics, University of Minnesota, Minneapolis, MN.
  • Lampland AL; Department of Pediatrics, University of Minnesota, Minneapolis, MN; Department of Pediatrics, Children's Minnesota, St. Paul, MN.
  • Leone TA; Department of Pediatrics, Columbia University, New York, NY.
  • Rudser KD; Department of Biostatistics, University of Minnesota, Minneapolis, MN.
  • Finer NN; Department of Pediatrics, University of California-San Diego, San Diego, CA.
  • Rich WD; Department of Pediatrics, Sharp Mary Birch, San Diego, CA.
  • Merritt TA; Department of Pediatrics, Loma Linda University, Loma Linda, CA.
  • Czynski AJ; Department of Pediatrics, Loma Linda University, Loma Linda, CA.
  • Kessel JM; Department of Pediatrics, University of Wisconsin-Madison, Madison, WI.
  • Tipnis SM; Department of Pediatrics, University of Mississippi, Jackson, MS.
  • Stepka EC; Department of Pediatrics, University of Minnesota, Minneapolis, MN.
  • Mammel MC; Department of Pediatrics, University of Minnesota, Minneapolis, MN; Department of Pediatrics, Children's Minnesota, St. Paul, MN.
J Pediatr ; 193: 40-46.e1, 2018 02.
Article en En | MEDLINE | ID: mdl-29174079
ABSTRACT

OBJECTIVE:

To determine if preterm infants with moderate respiratory distress syndrome on continuous positive airway pressure (CPAP) who received surfactant via a laryngeal mask airway (LMA) would have a decreased rate of intubation and mechanical ventilation compared with those on CPAP who did not receive surfactant. STUDY

DESIGN:

In this prospective, multicenter, randomized controlled trial, 103 premature infants 280/7-356/7 weeks gestation, ≥1250 g and ≤36 hours old on CPAP requiring fraction of inspired oxygen 0.30-0.40 were assigned to receive surfactant administered through an LMA then placed back on CPAP (LMA group) or maintained on CPAP with no surfactant administered (control group). The primary outcome was treatment failure necessitating intubation and mechanical ventilation in the first 7 days of life.

RESULTS:

Surfactant administration through an LMA (n = 50) significantly decreased the rate of intubation and mechanical ventilation compared with controls (n = 53) 38% vs 64%, respectively, OR 0.30 (95% CI 0.13, 0.70), P = .006, number needed to treat 4). There were no serious adverse events associated with placement of the LMA or surfactant administration.

CONCLUSIONS:

In premature neonates with moderate respiratory distress syndrome, surfactant administered through an LMA decreased the rate of intubation and mechanical ventilation. This intervention may have significant impact on clinical care in both high and low resource settings. TRIAL REGISTRATION ClinicalTrials.gov NCT01116921.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Surfactantes Pulmonares / Máscaras Laríngeas / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male / Newborn Idioma: En Revista: J Pediatr Año: 2018 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Surfactantes Pulmonares / Máscaras Laríngeas / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male / Newborn Idioma: En Revista: J Pediatr Año: 2018 Tipo del documento: Article