Your browser doesn't support javascript.
loading
Sensitivity and specificity of two dried blood spot methods for HIV-1 viral load monitoring among patients in Hanoi, Vietnam.
Pollack, Todd M; Duong, Hao T; Truong, Phuong T; Pham, Thuy T; Do, Cuong D; Colby, Donn.
Afiliación
  • Pollack TM; The Partnership for Health Advancement in Vietnam, Beth Israel Deaconess Medical Center, Hanoi, Vietnam.
  • Duong HT; Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, United States of America.
  • Truong PT; The Partnership for Health Advancement in Vietnam, Beth Israel Deaconess Medical Center, Hanoi, Vietnam.
  • Pham TT; Department of Microbiology, Bach Mai Hospital, Hanoi, Vietnam.
  • Do CD; The Partnership for Health Advancement in Vietnam, Beth Israel Deaconess Medical Center, Hanoi, Vietnam.
  • Colby D; Department of Infectious Diseases, Bach Mai Hospital, Hanoi, Vietnam.
PLoS One ; 13(1): e0191411, 2018.
Article en En | MEDLINE | ID: mdl-29346431
The use of dried blood spot (DBS) specimens for HIV viral load (VL) monitoring is recommended to support the roll-out of routine VL monitoring in low and middle income countries (LMICs). To better understand the use of DBS for VL monitoring, we evaluated two DBS testing methods, Roche TaqMan® Free Virus Evolution protocol (DBS-FVE) and Roche TaqMan® SPEX protocol (DBS-SPEX)) in patients receiving ART at an HIV clinic in Hanoi, Vietnam. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each DBS testing method at the thresholds of 1000 and 5000 copies/ml compared to plasma VL. At a threshold of 1000 copies/ml, sensitivity, specificity, PPV and NPV of the DBS-SPEX method were 98.8% (95% CI: 93.3%-100%), 74.3% (95% CI: 70.8%-77.5%), 31.5% (95% CI: 25.8%-37.6%), and 99.8% (95% CI: 98.9%-100%), respectively. Increasing the VL threshold value to 5000 copies/ml improved specificity (97.9% CI: 96.6%-98.9%) and PPV (83.9% CI: 74.5%-90.9%). Using the DBS-FVE method, at the threshold of 1000 copies/ml and with a correction factor of +0.3 log copies/ml, sensitivity was 95.1% (87.8%-98.6%) and specificity was 98.8% (97.7%-99.5%). Sensitivity decreased at the threshold of 5000 copies/ml (65.8%, 95% CI: 54.3%-76.1%). With a correction factor of +0.7 log copies/ml, the sensitivity was 96.3% (89.6%-99.2%) and specificity was 98.2% (96.9%-99.1%) at the threshold of 1000 copies/ml. We found that the Roche DBS-FVE method, with a +0.7 log copies/ml correction factor, performed well with sensitivity and specificity greater than 96% at a VL threshold of 1000 copies/m. These findings add to the growing body of evidence supporting the use of DBS VL testing for ART monitoring. Future research should evaluate the association between VL results by DBS and clinical outcome measures such as HIV drug resistance, morbidity, and mortality.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Infecciones por VIH / Carga Viral / Monitoreo Fisiológico Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Vietnam

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Infecciones por VIH / Carga Viral / Monitoreo Fisiológico Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Vietnam