Your browser doesn't support javascript.
loading
Performance assessment of a fully automated electro-chemiluminescence immunoassay system for serum S100B protein.
Anastasi, E; Gennarini, G; Del Monte, C; Colaprisca, B; Tartaglione, S; Di Segni, C; Angeloni, A.
Afiliación
  • Anastasi E; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Gennarini G; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Del Monte C; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Colaprisca B; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Tartaglione S; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Di Segni C; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
  • Angeloni A; Department of Molecular Medicine, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
J Biol Regul Homeost Agents ; 32(4): 1039-1043, 2018.
Article en En | MEDLINE | ID: mdl-30043591
ABSTRACT
The altered expression levels of S100 proteins can lead to four different categories of diseases diseases of the heart and of the central nervous system, inflammatory disorders and cancer. Various studies have shown the lack of harmonization of the results obtained with different methods, mainly due to different performances and measurements of S100B. The purpose of this work was to compare quantitatively the fully automated Elecsys® immunoassay with the reference immunoenzimatic method CanAg® EIA for serum S100B protein. In the study serum samples were analyzed of 161 patients 85 females (aged 22-83 years) and 76 males (aged 16-90 years), affected by oncological and non-oncological pathologies. Passing–Bablok regression was used to analyze the comparison between the assays; it showed a strong interassay correlation r = 0.9350 (95% CI =0.9122 – 0.9520), with an intercept of 0.02063 (95% CI=-0.02850 – 0.01400) and a slope of 1.1125 (95% CI=1.0200 – 1.2417). Elecsys® S100 assay should be preferred to CanAg® S100 for better standardization, good reliability and precision but also with the aim to reduce costs and obtain results in a shorter time.
Asunto(s)
Buscar en Google
Base de datos: MEDLINE Asunto principal: Ensayo de Inmunoadsorción Enzimática / Biomarcadores / Subunidad beta de la Proteína de Unión al Calcio S100 / Mediciones Luminiscentes Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Biol Regul Homeost Agents Asunto de la revista: BIOLOGIA / BIOQUIMICA Año: 2018 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Base de datos: MEDLINE Asunto principal: Ensayo de Inmunoadsorción Enzimática / Biomarcadores / Subunidad beta de la Proteína de Unión al Calcio S100 / Mediciones Luminiscentes Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Biol Regul Homeost Agents Asunto de la revista: BIOLOGIA / BIOQUIMICA Año: 2018 Tipo del documento: Article País de afiliación: Italia