Your browser doesn't support javascript.
loading
Four-dimensional calibration turntable of the motional Stark effect diagnostic on EAST.
Huang, X; Liu, D M; Liu, C; Fu, J; Wan, B N; Lyu, B; Wu, Z W; Holcomb, C T; Ko, J; Rowan, W L; Huang, H; Miao, G Z.
Afiliación
  • Huang X; School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China.
  • Liu DM; School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China.
  • Liu C; School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China.
  • Fu J; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China.
  • Wan BN; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China.
  • Lyu B; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China.
  • Wu ZW; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China.
  • Holcomb CT; Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94550, USA.
  • Ko J; National Fusion Research Institute, Yuseong, Daejeon 305-333, South Korea.
  • Rowan WL; Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712, USA.
  • Huang H; Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712, USA.
  • Miao GZ; School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China.
Rev Sci Instrum ; 89(10): 10B108, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30399705
ABSTRACT
The motional Stark effect (MSE) diagnostic is applied to measure the safety factor q and current density profile of a tokamak device, which are important parameters in realizing the high-performance and long-pulse steady state of a tokamak. A single-channel MSE diagnostic based on dual photoelastic modulators, whose sightline meets with the neutral beam injection at a major radius of R = 2.12 m, has been built for the D window of the Experimental Advanced Superconducting Tokamak (EAST). According to the requirements of MSE diagnostic polarimetric calibration, a high-precision four-dimensional calibration turntable, driven by four stepping motors and controlled by software running on the computer, was designed for EAST. The turntable allows us to rapidly calibrate the MSE diagnostic in a series of positions and angles during EAST maintenance. The turntable can move in four dimensions of translation, yaw, pitch, and roll of the polarizer and can create linearly polarized light at any given angle with accuracy of ∼0.05° for the MSE system offline calibration. The experimental results of the MSE diagnostic calibration in the laboratory show that the turntable has the advantages of high positioning accuracy, flexible spatial movement, and convenient control and fully meets the calibration requirements of an MSE diagnosis system.

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: China