Your browser doesn't support javascript.
loading
Macular Vascular Microcirculation in Eyes With Open-angle Glaucoma Using Different Visual Field Severity Classification Systems.
Bojikian, Karine D; Nobrega, Priscilla; Wen, Joanne C; Zhang, Qinqin; Mudumbai, Raghu C; Johnstone, Murray A; Wang, Ruikang K; Chen, Philip P.
Afiliación
  • Bojikian KD; Departments of Ophthalmology.
  • Nobrega P; Departments of Ophthalmology.
  • Wen JC; Departments of Ophthalmology.
  • Zhang Q; Bioengineering, University of Washington, Seattle, WA.
  • Mudumbai RC; Departments of Ophthalmology.
  • Johnstone MA; Departments of Ophthalmology.
  • Wang RK; Departments of Ophthalmology.
  • Chen PP; Bioengineering, University of Washington, Seattle, WA.
J Glaucoma ; 28(9): 790-796, 2019 09.
Article en En | MEDLINE | ID: mdl-31233458
ABSTRACT
PRECIS We found significant differences in macular vascular microcirculation between normal and glaucomatous eyes using optical coherence tomography angiography (OCTA). Macular vascular microcirculation changes also showed significant correlations with visual field (VF) severity classification systems.

PURPOSE:

To correlate VF severity defined by different classification systems and macular vascular microcirculation in eyes with glaucoma using OCTA. PATIENTS AND

METHODS:

Twenty normal and 58 open-angle glaucoma (OAG) eyes were scanned using a swept-source OCTA (Plex Elite 9000) and macular vascular microcirculation was measured by calculating the overall blood flux index (BFI) and vessel area density (VAD) over the entire 6×6 mm area excluding the big retinal vessels. Glaucomatous eyes were staged into severity groups based on 4 VF severity classifications Hodapp-Parrish-Anderson scale, Glaucoma Severity Staging system, ICD-10 glaucoma staging definitions, and VF mean deviation. Central 10-degree VF mean sensitivity (CMS) was calculated based on 24-2 VF. One-way analysis of variance was used to analyze the differences and correlation between macular vascular microcirculation and other clinical parameters.

RESULTS:

Glaucomatous eyes had significantly lower ganglion cell and inner plexiform layer BFI and VAD (P<0.0001) compared with normal eyes. In OAG patients, BFI and VAD were significantly higher in mild OAG compared with severe OAG with all VF disease severity classification systems (P<0.001). Glaucoma Severity Staging had the highest correlation with changes in macular vascular microcirculation metrics (r=0.734 for BFI; r=0.647 for VAD) and VF CMS had highest correlation with macular vascular microcirculation metrics (r=0.887 for BFI; r=0.903 for VAD).

CONCLUSION:

Macular vascular microcirculation metrics detected by OCTA correlate with disease severity in glaucomatous eyes. VF CMS, calculated from only 12 tested central 10-degree points, correlated best with macular OCTA.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Disco Óptico / Vasos Retinianos / Trastornos de la Visión / Campos Visuales / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Glaucoma Asunto de la revista: OFTALMOLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Disco Óptico / Vasos Retinianos / Trastornos de la Visión / Campos Visuales / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Glaucoma Asunto de la revista: OFTALMOLOGIA Año: 2019 Tipo del documento: Article