In vivo evaluation of human patellar tendon microstructure and microcirculation with diffusion MRI.
J Magn Reson Imaging
; 51(3): 780-790, 2020 03.
Article
en En
| MEDLINE
| ID: mdl-31407413
ABSTRACT
BACKGROUND:
Patellar tendon (PT) microstructure integrity and microcirculation status play a crucial role in the progression of tendinopathy and tendon repair.PURPOSE:
To assess the feasibility and robustness of stimulated-echo based diffusion-weighted MRI with readout-segmented echo-planar imaging (ste-RS-EPI) for noninvasive assessment of microstructure and microcirculation of human PT. STUDY TYPE Prospective.SUBJECTS:
Fifteen healthy volunteers. FIELD STRENGTH/SEQUENCE PT diffusion tensor imaging (DTI) and intravoxel incoherent motion (IVIM) were acquired with an ste-RS-EPI protocol on a 3T MRI scanner. ASSESSMENT Subjects were positioned with their PT at the magic angle. DTI-derived parameters including axial diffusivity (AD), radial diffusivity (RD), mean diffusivity (MD), and fractional anisotropy (FA) were estimated with b-values of 0 and 800 s/mm2 and 12 diffusion directions. IVIM-derived parameters, f p , D* × f p , V b , and D* × V b were assessed in the central-third and the outer-two thirds of the PT with b-values of 0, 20, 30, 60, 80, 120, 200, 400, and 600 s/mm2 in three orthogonal directions. STATISTICAL TESTS Paired t-tests were used to evaluate differences in IVIM parameters between the central-third and outer-two thirds regions of the patellar tendon. Paired t-tests and within-subject coefficient of variation were used to assess the intra- and intersession reproducibility of PT DTI and IVIM parameters.RESULTS:
DTI parameters for healthy PT were 1.54 ± 0.09 × 10-3 mm2 /s, 1.01 ± 0.05 × 10-3 mm2 /s, 1.18 ± 0.06 × 10-3 mm2 /s, and 0.30 ± 0.04 for AD, RD, MD, and FA, respectively. Significantly higher (P < 0.05) IVIM parameters f p and D* × f p were observed in the outer-two thirds (6.1% ± 2.4% and 95.2 ± 49.6, respectively) compared with the central-third (3.8% ± 2.3% and 48.6 ± 35.2, respectively) of the PT. DATACONCLUSION:
Diffusion MRI of PT with an ste-RS-EPI protocol is clinically feasible. Both DTI- and IVIM-derived parameters of the PT demonstrated good test-retest reproducibility and interrater reliability. LEVEL OF EVIDENCE 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2020;51780-790.Palabras clave
Texto completo:
1
Base de datos:
MEDLINE
Asunto principal:
Ligamento Rotuliano
/
Imagen de Difusión Tensora
Tipo de estudio:
Guideline
/
Observational_studies
Límite:
Humans
Idioma:
En
Revista:
J Magn Reson Imaging
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2020
Tipo del documento:
Article
País de afiliación:
Estados Unidos