Rod-like Co based metal-organic framework embedded into mesoporous carbon composite modified glassy carbon electrode for effective detection of pyrazinamide and isonicotinyl hydrazide in biological samples.
Yan, Yu; Ma, Jicheng; Bo, Xiangjie; Guo, Liping.
Afiliación
  • Yan Y; Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, PR China.
  • Ma J; Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, PR China. Electronic address: majc829@nenu.edu.cn.
  • Bo X; Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, PR China.
  • Guo L; Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, PR China. Electronic address: guolp078@nenu.edu.cn.
Talanta ; 205: 120138, 2019 Dec 01.
Article en En | MEDLINE | ID: mdl-31450409
ABSTRACT
Herein, we report a novel composite fabricated via embedding rod-like Co based metal-organic framework (Co-MOF-74) crystals into MC matrix for the first time. The introduction of MC astricts the size of Co-MOF-74 crystals, enlarges the pore size and improves the electrical conductivity, which lead to the good electrochemical properties of the composite. The fabricated sensor based on Co-MOF-74@MC exhibits superior electrocatalytic activity toward the reduction of pyrazinamide (PZA) and the oxidation of isonicotinyl hydrazide (INZ). Under optimized conditions, the sensor shows two linear ranges from 0.3 to 46.5 µM and 46.5-166.5 µM with a high sensitivity of 7.2 µA µM-1 cm-2 and a detection limit of 0.21 µM for the determination of PZA. The electroanalytical sensing of INZ also gives two linear ranges of 0.15-1.55 µM and 1.55-592.55 µM with a detection limit of 0.094 µM. The mechanism involved was also discussed, briefly. The sensor is assessed toward the detection of PZA and INZ in human serum and urine samples. Recovery values varied from 97.08 to 103.20% for PZA sensing and 96.67-102.90% for INZ sensing, revealing the promising practicality of sensor for PZA and INZ detection.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Pirazinamida / Análisis Químico de la Sangre / Carbono / Urinálisis / Cobalto / Estructuras Metalorgánicas / Vidrio / Isoniazida Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2019 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Pirazinamida / Análisis Químico de la Sangre / Carbono / Urinálisis / Cobalto / Estructuras Metalorgánicas / Vidrio / Isoniazida Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2019 Tipo del documento: Article