A Step-by-Step Problem-Solving Strategy in a Patient With Heart Failure and Cerebral Aneurysm.
Rossi, Elena; Fabozzo, Assunta; Pradegan, Nicola; Tessari, Chiara; Gabrieli, Joseph Domenico; Causin, Francesco; Tarzia, Vincenzo; Bottio, Tomaso; Gerosa, Gino.
Afiliación
  • Rossi E; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Fabozzo A; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Pradegan N; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Tessari C; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Gabrieli JD; Neuroradiology Unit, Department of Neurosciences, University Hospital of Padua, Padua, Italy.
  • Causin F; Neuroradiology Unit, Department of Neurosciences, University Hospital of Padua, Padua, Italy.
  • Tarzia V; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Bottio T; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy.
  • Gerosa G; Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, University of Padua, Padua, Italy. Electronic address: gino.gerosa@unipd.it.
Ann Thorac Surg ; 109(4): e285-e287, 2020 04.
Article en En | MEDLINE | ID: mdl-31473176
ABSTRACT
Left ventricular assist device implantation is an established treatment for patients with end-stage heart failure. The HeartMate 3 (Abbott Laboratories, Abbott Park, IL) is a continuous-flow centrifugal pump, recently introduced in the clinic, that has shown greater hemocompatibility compared with similar devices of previous generations. Nevertheless, anticoagulation is still required after HeartMate 3 implant to avoid pump dysfunction. Hereafter, we describe the case of a patient candidate to left ventricular assist device implantation for end-stage heart failure presenting a concomitant cerebrovascular lesion, accidentally found during preoperative assessment, that would have contraindicated the procedure (for the prohibitive risk of cerebral hemorrhage), unless a step by step problem-solving approach was adopted.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aneurisma Intracraneal / Corazón Auxiliar / Implantación de Prótesis / Insuficiencia Cardíaca Tipo de estudio: Etiology_studies Límite: Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 2020 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aneurisma Intracraneal / Corazón Auxiliar / Implantación de Prótesis / Insuficiencia Cardíaca Tipo de estudio: Etiology_studies Límite: Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 2020 Tipo del documento: Article País de afiliación: Italia