Your browser doesn't support javascript.
loading
Continuous Detection of Increasing Concentrations of Thrombin Employing a Label-Free Photonic Crystal Aptasensor.
Martínez-Pérez, Paula; Gómez-Gómez, Maribel; Angelova, Todora; Griol, Amadeu; Hurtado, Juan; Bellieres, Laurent; García-Rupérez, Jaime.
Afiliación
  • Martínez-Pérez P; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • Gómez-Gómez M; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • Angelova T; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • Griol A; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • Hurtado J; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • Bellieres L; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
  • García-Rupérez J; Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
Micromachines (Basel) ; 11(5)2020 Apr 28.
Article en En | MEDLINE | ID: mdl-32354154
ABSTRACT
Thrombin generation is a complex and finely regulated pathway that provokes dynamical changes of thrombin concentration in blood when a vascular injury occurs. In order to characterize the initiation phase of such process, when thrombin concentration is in the nmol/L range, a label-free optical aptasensor is proposed here. This aptasensor combines a 1D photonic crystal structure consisting of a silicon corrugated waveguide with thrombin binding aptamers on its surface as bioreceptors. As a result, this aptasensor has been demonstrated to specifically detect thrombin concentrations ranging from 270 pmol/L to 27 nmol/L with an estimated detection limit of 33.5 pmol/L and a response time of ~2 min. Furthermore, it has also been demonstrated that this aptasensor is able to continuously respond to consecutive increasing concentrations of thrombin and to detect binding events as they occur. All these features make this aptasensor a good candidate to continuously study how thrombin concentration progressively increases during the initiation phase of the coagulation cascade.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Micromachines (Basel) Año: 2020 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Micromachines (Basel) Año: 2020 Tipo del documento: Article País de afiliación: España