Your browser doesn't support javascript.
loading
[Analytical and clinical guidelines on neonatal bilirubinemia]. / Recommandations analytiques et cliniques pour l'utilisation de la bilirubinémie en néonatalogie.
Mailloux, Agnès; Cortey, Anne; Delatour, Vincent; Poupon, Carole; Rota, Michèle; Schmitt, François; Vaubourdolle, Michel.
Afiliación
  • Mailloux A; Unité fonctionnelle d'expertise en immuno-hémobiologie périnatale, Centre national de référence en hémobiologie périnatale (CNRHP), DMU BioGeM-Site Saint-Antoine, AP-HP, Sorbonne Université, Paris, France.
  • Cortey A; Unité clinique de soins des incompatibilités fœto-maternelles et ictère néo-natal, Centre national de référence en hémobiologie périnatale (CNRHP) DMU OriGyn -Site Armand Trousseau, AP-HP, Sorbonne Université, AP-HP.
  • Delatour V; Laboratoire national de métrologie et d'essais, Paris, France.
  • Poupon C; Laboratoire de biologie médicale, Centre hospitalier de Gonesse, France.
  • Rota M; Laboratoire de biologie médicale, Centre hospitalier intercommunal de Créteil, France.
  • Schmitt F; Laboratoire de biologie médicale, Groupe hospitalier Bretagne Sud, France.
  • Vaubourdolle M; Département de biochimie, hormonologie et suivi thérapeutique DMU BioGeM-Site Saint-Antoine, AP-HP, Sorbonne Université, France.
Ann Biol Clin (Paris) ; 78(4): 383-397, 2020 08 01.
Article en Fr | MEDLINE | ID: mdl-32666924
ABSTRACT
The SFBC-CNBH-CNRHP "Neonatal bilirubin" working group performed a biological and clinical study on bilirubin use in neonates for reliable diagnosis and appropriate management of neonatal jaundice. A brief report of a national survey on analytical and biological practices in France is shown. The guidelines of the French Society of Neonatology (SFN) founded the decision of phototherapy set up upon an accurate lab measurement of total serum bilirubin. An abacus is proposed with defined thresholds, as a function of neonate lifetime in hours. However, several studies evidenced poor comparability of results obtained with the different available methods. This situation is partly due to the lack of reference materials, especially for high bilirubin concentrations. Clinical consequences might be observed. We present in this paper the results of a national harmonization study to progress on this issue. Beyond the analytical aspects, the clinical consequences of harmonization defects were investigated. Finally, guidelines for clinical laboratories are proposed, to be locally adapted.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tamizaje Neonatal / Guías de Práctica Clínica como Asunto / Hiperbilirrubinemia Neonatal / Pruebas Hematológicas / Ictericia Neonatal Tipo de estudio: Guideline / Prognostic_studies / Qualitative_research Límite: Humans / Newborn País/Región como asunto: Europa Idioma: Fr Revista: Ann Biol Clin (Paris) Año: 2020 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tamizaje Neonatal / Guías de Práctica Clínica como Asunto / Hiperbilirrubinemia Neonatal / Pruebas Hematológicas / Ictericia Neonatal Tipo de estudio: Guideline / Prognostic_studies / Qualitative_research Límite: Humans / Newborn País/Región como asunto: Europa Idioma: Fr Revista: Ann Biol Clin (Paris) Año: 2020 Tipo del documento: Article País de afiliación: Francia