Your browser doesn't support javascript.
loading
Mechanical circulatory support for early surgical repair of postinfarction ventricular septal defect with cardiogenic shock.
Vondran, Maximilian; Wehbe, Mahmoud S; Etz, Christian; Ghazy, Tamer; Rastan, Ardawan J; Borger, Michael A; Schroeter, Thomas.
Afiliación
  • Vondran M; University Department for Cardiac Surgery, Heart Center Leipzig, Leipzig, Germany.
  • Wehbe MS; Department of Cardiac and Vascular Thoracic Surgery, Philipps-University Hospital Marburg, Marburg, Germany.
  • Etz C; University Department for Cardiac Surgery, Heart Center Leipzig, Leipzig, Germany.
  • Ghazy T; Department of Cardiac Surgery, Sana Herzchirurgie Stuttgart, Stuttgart, Germany.
  • Rastan AJ; University Department for Cardiac Surgery, Heart Center Leipzig, Leipzig, Germany.
  • Borger MA; Department of Cardiac and Vascular Thoracic Surgery, Philipps-University Hospital Marburg, Marburg, Germany.
  • Schroeter T; Department of Cardiac and Vascular Thoracic Surgery, Philipps-University Hospital Marburg, Marburg, Germany.
Artif Organs ; 45(3): 244-253, 2021 Mar.
Article en En | MEDLINE | ID: mdl-32857884
Postinfarction ventricular septal defect (pVSD) due to acute myocardial infarction complicated by cardiogenic shock (CS) is associated with high mortality. The aim of this study was to determine the outcome of primary surgical repair of pVSD in patients with CS and examine whether it is influenced by the use of mechanical circulatory support (MCS) devices. Between October 1994 and April 2016, primary surgical repair of pVSD complicated by CS was performed in 53 patients. Thirty-six (68%) were implanted pre-operatively with an intra-aortic balloon pump (IABP), 4 (8%) with extracorporeal life support (ECLS), and 13 (24%) received no MCS device. Prospectively collected demographic and perioperative data were analyzed retrospectively. All-cause, 30-day mortality rates were analyzed and multivariate analysis was performed to differentiate independent risk factors. No pre-operatively implanted MCS device was able to improve 30-day survival, whereas pre-operatively implanted ECLS tended to have a positive effect (P = .106). The post-operative need for a MCS device or escalation of MCS invasiveness (IABP upgrade to ECLS) was associated with a higher 30-day mortality (P = .001) compared with patients without any MCS device or those with pre-operatively implanted MCS devices. An independent risk factor for 30-day mortality was the interval between acute myocardial infarction and surgery <7 days (OR 5.895, CI 1.615-21.515; P = .007). Pre-operative implantation of ECLS for CS tends to improve the outcome of early primary surgical pVSD repair. The need for a post-operative MCS device is associated with a worse 30-day survival after early primary surgical pVSD repair.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Choque Cardiogénico / Oxigenación por Membrana Extracorpórea / Defectos del Tabique Interventricular / Contrapulsador Intraaórtico / Infarto del Miocardio Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Choque Cardiogénico / Oxigenación por Membrana Extracorpórea / Defectos del Tabique Interventricular / Contrapulsador Intraaórtico / Infarto del Miocardio Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Año: 2021 Tipo del documento: Article País de afiliación: Alemania