Your browser doesn't support javascript.
loading
Highly selective sensor for the detection of Hg2+ ions using homocysteine functionalised quartz crystal microbalance with cross-linked pyridinedicarboxylic acid.
Rotake, Dinesh Ramkrushna; Kumar, Ajay; Darji, Anand D; Singh, Jitendra.
Afiliación
  • Rotake DR; Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India. dinesh.rotake@gmail.com.
  • Kumar A; Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India.
  • Darji AD; Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India.
  • Singh J; Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India.
IET Nanobiotechnol ; 14(7): 563-573, 2020 Sep.
Article en En | MEDLINE | ID: mdl-33010131
ABSTRACT
This study reports an insightful portable vector network analyser (VNA)-based measurement technique for quick and selective detection of Hg2+ ions in nanomolar (nM) range using homocysteine (HCys)-functionalised quartz-crystal-microbalance (QCM) with cross-linked-pyridinedicarboxylic acid (PDCA). The excessive exposure to mercury can cause damage to many human organs, such as the brain, lungs, stomach, and kidneys, etc. Hence, the authors have proposed a portable experimental platform capable of achieving the detection in 20-30 min with a limit of detection (LOD) 0.1 ppb (0.498 nM) and a better dynamic range (0.498 nM-6.74 mM), which perfectly describes its excellent performance over other reported techniques. The detection time for various laboratory-based techniques is generally 12-24 h. The proposed method used the benefits of thin-film, nanoparticles (NPs), and QCM-based technology to overcome the limitation of NPs-based technique and have LOD of 0.1 ppb (0.1 µg/l) for selective Hg2+ ions detection which is many times less than the World Health Organization limit of 6 µg/l. The main advantage of the proposed QCM-based platform is its portability, excellent repeatability, millilitre sample volume requirement, and easy process flow, which makes it suitable as an early warning system for selective detection of mercury ions without any costly measuring instruments.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Nanopartículas del Metal / Tecnicas de Microbalanza del Cristal de Cuarzo / Oro / Homocisteína / Iones / Mercurio Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: IET Nanobiotechnol Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Nanopartículas del Metal / Tecnicas de Microbalanza del Cristal de Cuarzo / Oro / Homocisteína / Iones / Mercurio Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: IET Nanobiotechnol Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: India