Evaluation of 24-segment sphericity index of fetal heart using FetalHQ.
Hata, Toshiyuki; Koyanagi, Aya; Yamanishi, Tomomi; Bouno, Saori; Takayoshi, Riko; AboEllail, Mohamed Ahmed Mostafa; Miyake, Takahito.
Afiliación
  • Hata T; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Koyanagi A; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan.
  • Yamanishi T; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Bouno S; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Takayoshi R; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • AboEllail MAM; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Miyake T; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan.
J Matern Fetal Neonatal Med ; 35(23): 4573-4579, 2022 Dec.
Article en En | MEDLINE | ID: mdl-33280470
ABSTRACT

OBJECTIVE:

To evaluate the 24-segment sphericity index (SI) of the fetal heart using FetalHQ regarding the change with advancing gestation and reproducibility.

METHODS:

Eighty-one pregnant women at 18-21 + 6 and 28-31 + 6 weeks were studied using FetalHQ to calculate 24-segment SI of left and right ventricles. Intra- and inter-class correlation coefficients and intra- and inter-observer agreements of measurements for SI were assessed in each segment.

RESULTS:

With respect to intra-observer reproducibility, all SI values showed correlations between 0.596 and 0.774 for the left ventricle, and between 0.491 and 0.764 for the right ventricle, with good intra-observer agreements except for right ventricular segment 11-15. With respect to inter-observer reproducibility, all SI values showed correlations between 0.473 and 0.755 for the left ventricle, and between 0.48 and 0.767 for the right ventricular segment 1-18. However, right ventricular segment 19-24 showed no correlations. Good inter-observer agreements were noted in the right ventricle, whereas poor inter-observer agreements were evident in the left ventricle.There were significant differences in the mean SI values in the apical segment of the left ventricle between 18-21 + 6 and 28-31 + 6 weeks (p < .05), whereas there were no significant differences in the mean SI values in the right ventricle between both gestational ages.

CONCLUSION:

These results show that measurements of 24-segment SI of fetal heart had relatively low reliability of measurements performed by experienced sonographers. This may suggest that more training on proper placement of the 3 end-systolic and end-diastolic reference points during the initial analysis may be relevant.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: J Matern Fetal Neonatal Med Asunto de la revista: OBSTETRICIA / PERINATOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: J Matern Fetal Neonatal Med Asunto de la revista: OBSTETRICIA / PERINATOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón