Your browser doesn't support javascript.
loading
Toroidal soft x-ray array on the EXL-50 spherical tokamak.
Huang, X L; Zhang, Y P; Zhu, Y B; Li, X; He, L; Li, Y X; Zhou, J; Cheng, S K; Yang, Y M; Bai, R H; Zhao, X; Tao, R Y; Chen, B; Dai, L L; Zeng, G Q; Liu, Y; Liu, M S.
Afiliación
  • Huang XL; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Zhang YP; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhu YB; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Li X; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • He L; Chengdu University of Technology, Chengdu 610059, China.
  • Li YX; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Zhou J; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Cheng SK; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Yang YM; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Bai RH; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Zhao X; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Tao RY; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Chen B; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Dai LL; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
  • Zeng GQ; Chengdu University of Technology, Chengdu 610059, China.
  • Liu Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Liu MS; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China.
Rev Sci Instrum ; 92(5): 053501, 2021 May 01.
Article en En | MEDLINE | ID: mdl-34243359
ABSTRACT
A toroidal soft x-ray array system for spectrum and intensity measurements on the EXL-50 spherical tokamak is described. Silicon drift detectors and digital multichannel analyzers are adopted for all 21 channels of the array, and an average energy resolution of 147 eV at 5.89 keV has been achieved at count rates over 500 kcps. In total, 20 channels of the array are symmetrically observed in both co- and counter-current directions on the EXL-50 mid-plane with a spatial resolution of around 10 cm, and the remaining one serves as a background reference channel. Tungsten emissions from tungsten coating of the limiters on the central post are observed. The influence of hard x rays on measured soft x-ray spectra and system operation is discussed.

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2021 Tipo del documento: Article País de afiliación: China