Your browser doesn't support javascript.
loading
Optimization and validation of a two-step method for the determination of polybrominated diphenyl ethers in Croatian house dust samples.
Jagic, Karla; Dvorscak, Marija; Juric, Andreja; Safner, Toni; Klincic, Darija.
Afiliación
  • Jagic K; Biochemistry and Organic Analytical Chemistry Unit, Institute for Medical Research and Occupational Health, Ksaverska Cesta 2, HR-10000 Zagreb, Croatia. mdvorscak@imi.hr.
  • Dvorscak M; Biochemistry and Organic Analytical Chemistry Unit, Institute for Medical Research and Occupational Health, Ksaverska Cesta 2, HR-10000 Zagreb, Croatia. mdvorscak@imi.hr.
  • Juric A; Analytical Toxicology and Mineral Metabolism Unit, Institute for Medical Research and Occupational Health, Ksaverska Cesta 2, HR-10000 Zagreb, Croatia.
  • Safner T; Department of Plant Breeding, Genetics, Biometrics and Experimentation, Faculty of Agriculture, University of Zagreb, Svetosimunska Cesta 25, HR-10000 Zagreb, Croatia and Centre of Excellence for Biodiversity and Molecular Plant Breeding (CoE CroP-BioDiv), Svetosimunska Cesta 25, HR-10000 Zagreb, Cr
  • Klincic D; Biochemistry and Organic Analytical Chemistry Unit, Institute for Medical Research and Occupational Health, Ksaverska Cesta 2, HR-10000 Zagreb, Croatia. mdvorscak@imi.hr.
Anal Methods ; 13(31): 3504-3510, 2021 08 12.
Article en En | MEDLINE | ID: mdl-34268546
ABSTRACT
Microwave-assisted extraction was applied as a method for extraction of seven polybrominated diphenyl ether (PBDE) congeners (28, 47, 99, 100, 153, 154, and 183) from house dust samples. Optimization of MAE experimental conditions was achieved using a multivariate design approach, and the results indicated that only the choice of extraction solvent had a statistically significant influence on extraction efficiency. The extract purification step was also investigated in detail with a goal to achieve effective cleaning, with minor solvent consumption. As the final operating conditions, 20 min MAE extraction from 1 g of dust with 20 mL of n-hexane acetone (1 1, v/v) at 80 °C and extract purification on an in-lab prepared column containing 2 g of neutral silica and 4 g of acidified silica, whereby the PBDEs were eluted from the column with 15 mL of n-hexane dichloromethane (4 1, v/v), were selected. The extracts were analyzed on a dual GC-µECD system, and GC-MS/MS was used as a confirmatory method. The performance of the optimized method was validated by analyzing spiked dust samples and a standard reference material (NIST 2585 "Organic Contaminants in House Dust"). Congener specific PBDE recovery ranged from 76% to 90% for the spiked samples (with very good repeatability; RSD < 7%) and the measured mass concentrations of selected PBDEs were in excellent agreement with certified values for a standard reference material. The proposed method was successfully applied to the analysis of targeted PBDEs in house dust samples.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Polvo / Éteres Difenilos Halogenados Idioma: En Revista: Anal Methods Año: 2021 Tipo del documento: Article País de afiliación: Croacia

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Polvo / Éteres Difenilos Halogenados Idioma: En Revista: Anal Methods Año: 2021 Tipo del documento: Article País de afiliación: Croacia