Your browser doesn't support javascript.
loading
Nontarget and high-throughput screening of pesticides and metabolites residues in tea using ultra-high-performance liquid chromatography and quadrupole-orbitrap high-resolution mass spectrometry.
Huang, Hetian; Li, Zhanbin; He, Yu; Huang, Lian; Xu, Xiaoli; Pan, Canping; Guo, Feng; Yang, Hongbo; Tang, Shi.
Afiliación
  • Huang H; School of Public Health, The Key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang 550025, China; Guizhou Academy of Testing and Analysis, Guiyang 550014, China; The Peoples Hospital of Liupanshui City, Liupanshui 553001,
  • Li Z; Guizhou Academy of Testing and Analysis, Guiyang 550014, China.
  • He Y; Guizhou Academy of Testing and Analysis, Guiyang 550014, China.
  • Huang L; School of Public Health, The Key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang 550025, China.
  • Xu X; Guizhou Academy of Testing and Analysis, Guiyang 550014, China.
  • Pan C; Department of Applied Chemistry, College of Science, China Agricultural University, Beijing 100094, China.
  • Guo F; National Research Center for Geoanalysis, Key Laboratory of Eco-Geochemistry, Ministry of Natural Resources, Beijing 100037, China. Electronic address: guofeng@mail.cgs.gov.cn.
  • Yang H; School of Public Health, The Key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang 550025, China; Guizhou Academy of Testing and Analysis, Guiyang 550014, China. Electronic address: hbyang@gzata.cn.
  • Tang S; The Peoples Hospital of Liupanshui City, Liupanshui 553001, China.
Article en En | MEDLINE | ID: mdl-34418760
A Sin-QuEChERS, coupled to UHPLC Q-Exactive Orbitrap MS, was used for nontargeted high-throughput rapid screening and quantitative analysis of residual pesticides and metabolites in green teas. The sample was extracted with 0.1% formic acid in acetonitrile with shaking, salted out and centrifuged, and purified with Sin-QuEChERS Nano solid phase extraction column; with Full MS/ddMS2 as the data collection mode, the database containing 384 pesticides combined with Trace Finder 3.0 software, In the absence of standard products, rapid screening and confirmation of potential pesticide residues in tea samples with accurate mass, isotope abundance ratio, secondary fragment ions, etc. 20 pesticides were used as quality controls to verify the screening method, and the linearity of these pesticides was between 1 and 200 µg/L, and the correlation coefficients were all greater than 0.9922. Moreover, the LOQ was between 0.002 and 0.01 mg/kg. The average recoveries of spiked tea samples were 74%-111%. Efficiency and reliability of this method were investigated by the analysis of 38 Chinese green tea samples. 18 potential residual pesticides were detected by non-targeted screening. The researchers then conducted a quantitative analysis of the 18 potential residual pesticides.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Té / Residuos de Plaguicidas / Cromatografía Líquida de Alta Presión Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Té / Residuos de Plaguicidas / Cromatografía Líquida de Alta Presión Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article