Your browser doesn't support javascript.
loading
HDlive Flow Silhouette with spatiotemporal image correlation for assessment of fetal cardiac structures at 12 to 14 + 6 weeks of gestation.
Hata, Toshiyuki; Koyanagi, Aya; Kawahara, Tomomi; Konishi, Miyu; Takayoshi, Riko; Miyagi, Yasunari; Miyake, Takahito.
Afiliación
  • Hata T; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Koyanagi A; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan.
  • Kawahara T; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Konishi M; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Takayoshi R; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Miyagi Y; Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan.
  • Miyake T; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan.
J Perinat Med ; 50(3): 313-318, 2022 Mar 28.
Article en En | MEDLINE | ID: mdl-34496162
ABSTRACT

OBJECTIVES:

To assess fetal cardiac structures using HDlive Flow Silhouette with spatiotemporal image correlation (STIC) at 12 to 14 + 6 weeks of gestation, and verify the feasibility of obtaining five cardiac views in the late first and early second trimesters of pregnancy. The fetal cardiac shape and the aspect of the descending aorta were also evaluated.

METHODS:

Eighty normal fetuses at 12 to 14 + 6 weeks of gestation were studied using trans-abdominal HDlive Flow Silhouette with STIC to assess the feasibility of five fetal cardiac views (frontal, spatial three-vessel, panoramic, posterior, and right lateral views). Target structures in each cardiac view were evaluated. 'Good' was assigned when all structures were noted, 'Fair' when only one structure was missed, and 'Poor' when two and more structures could not be detected. Frequencies of an elongated heart and those of a tortuous descending aorta were counted.

RESULTS:

Forty-nine fetuses were effectively included in the analysis. Success rates of 'Good' and 'Fair' were significantly higher with spatial three-vessel (p<0.01) and panoramic views (p<0.05). Frequencies of "Elongated heart", "Elongated left ventricle", and "Spherical heart" were 12.2, 6.2, and 81.6%, respectively. Frequencies of "Tortuous descending aorta" and "Straight descending aorta" were 12.2 and 87.8%, respectively.

CONCLUSIONS:

The feasibility of obtaining fetal five cardiac views using HDlive Flow Silhouette with STIC is good, and this technique provides useful information for evaluating fetal cardiac structures in the late first and early second trimesters of pregnancy.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Perinat Med Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Perinat Med Año: 2022 Tipo del documento: Article País de afiliación: Japón