Your browser doesn't support javascript.
loading
Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve.
Hori, Daijiro; Yamamoto, Takahiro; Kusadokoro, Sho; Fujimori, Tomonari; Mieno, Makiko Naka; Kimura, Naoyuki; Yamaguchi, Atsushi.
Afiliación
  • Hori D; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan. dhori07@jichi.ac.jp.
  • Yamamoto T; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
  • Kusadokoro S; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
  • Fujimori T; Department of Medical Informatics, Center for Information, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi, 329-0498, Japan.
  • Mieno MN; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
  • Kimura N; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
  • Yamaguchi A; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
J Artif Organs ; 25(3): 238-244, 2022 Sep.
Article en En | MEDLINE | ID: mdl-34727259
ABSTRACT
Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD - 37 ± 22.7 mm2 vs. no CD - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD - 4.4 ± 2.77 mm vs. no CD - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD 114 ± 28.4 mm2 vs. no CD - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD 3.9 ± 2.08 mm vs. no CD - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Artif Organs Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Artif Organs Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2022 Tipo del documento: Article País de afiliación: Japón