Sensitivity Improvement of Phi-OTDR by Fiber Cable Coils.
Sensors (Basel)
; 21(21)2021 Oct 26.
Article
en En
| MEDLINE
| ID: mdl-34770385
We present a theoretical and experimental study in which we increased the sensitivity of a phase-sensitive optical time-domain reflectometer (phi-OTDR). This was achieved by constructing coils in the sensor cable, which increased the total amplitude of the impact on the fiber. We demonstrate this theoretically using the example of a phase-sensitive reflectometer model and practically in testing grounds with a buried nearby conventional sensor and a sensor with coils. The sensitivity increased 2.2 times. We detected 95% of events when using coils, versus 20% when using a straight cable. The suggested method does not require any modifications to the device.
Palabras clave
Texto completo:
1
Base de datos:
MEDLINE
Asunto principal:
Tecnología de Fibra Óptica
Tipo de estudio:
Diagnostic_studies
Idioma:
En
Revista:
Sensors (Basel)
Año:
2021
Tipo del documento:
Article
País de afiliación:
Rusia