Analysis of a New Artificial Muscle Type Dynamic Orthosis for Wrist Joint Disease Using a Three-dimensional Motion Analyzer.
Nakayama, Jun; Sunagawa, Kosaku; Ogawa, Kazunori; Oka, Hisao.
Afiliación
  • Nakayama J; Department of Allied Health Sciences, Kansai University of Welfare Sciences, Osaka, Japan.
  • Sunagawa K; Department of Allied Health Sciences, Kansai University of Welfare Sciences, Osaka, Japan.
  • Ogawa K; Daiya Industrial Inc, Okayama City, Japan.
  • Oka H; Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama City, Japan.
Prog Rehabil Med ; 6: 20210043, 2021.
Article en En | MEDLINE | ID: mdl-34786516
OBJECTIVES: Recently, the dart-throwing motion (DTM) has attracted attention as a functional direction of wrist joint motion. Consequently, we devised a new artificial muscle-type dynamic orthosis (Dynamic Traction Splint by Artificial Muscle, DTSaM) to reproduce DTM. This study analyzed the automatic motion of the wrist joint using a three-dimensional motion analysis system to assess how closely the DTSaM replicates DTM. METHODS: The DTSaM orthosis incorporates two McKibben-type rubber artificial muscles, and measurements were performed using image analysis software and a three-dimensional motion analysis system. The wrist radial angle (WRA) was defined as the angle between the line connecting the head of the index finger metacarpal to the radial styloid process and the line connecting the radial styloid process to the lateral epicondyle of the humerus. WRAs were investigated from 60° of palmar flexion to 60° of dorsiflexion. RESULTS: For dorsiflexion, comparisons of radial deviation and wrist ulnar angle (WUA) between the motion obtained using the DTSaM orthosis and active DTM showed a significant difference (P <0.05) at 30° and 60°, respectively. For palmar flexion, the same comparison showed a significant difference for both the ulnar and radial deviations (30°, P <0.05; and 60°, P <0.01, respectively). Furthermore, WUA showed a significant difference at 50° (P <0.05). Intraclass correlation coefficient analyses yielded good reliability with an average value of ≥0.8. CONCLUSION: The DTSaM orthosis produces a motion similar to the DTM. It is hoped that the use of the DTSaM orthosis will help to shorten the treatment period for patients with wrist disease.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Prog Rehabil Med Año: 2021 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Prog Rehabil Med Año: 2021 Tipo del documento: Article País de afiliación: Japón