Your browser doesn't support javascript.
loading
An LC/MS/MS method for quantifying testosterone and dehydroepiandrosterone sulfate in four different serum samples during a single run.
Fujimura, Shunsuke; Ito, Takenori; Ogawa, Shoujiro; Ishige, Takayuki; Nishimoto-Kusunose, Shoichi; Higashi, Tatsuya.
Afiliación
  • Fujimura S; Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda, 278-8510, Japan.
  • Ito T; Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda, 278-8510, Japan.
  • Ogawa S; Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda, 278-8510, Japan.
  • Ishige T; Faculty of Pharmacy and Pharmaceutical Sciences, Fukuyama University, 1 Sanzo, Gakuen-cho, Fukuyama, 729-0292, Japan.
  • Nishimoto-Kusunose S; Division of Laboratory Medicine, Chiba University Hospital, 1‒8‒1 Inohana, Chuo, Chiba, 260-8677, Japan.
  • Higashi T; Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda, 278-8510, Japan.
Anal Sci ; 38(1): 167-173, 2022 01.
Article en En | MEDLINE | ID: mdl-35287219
ABSTRACT
Simultaneous measurements of the circulating testosterone (TS) and dehydroepiandrosterone sulfate (DHEAS) are deemed to be helpful for the assessment of men's health. Liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) is the most reliable methodology for this purpose; however, it has room for improvement in analysis throughput. In this study, a quadruplicate of the Girard reagents was used to develop an LC/ESI-MS/MS method capable of quantifying TS and DHEAS in four different serum samples in a single run. The four serum samples were separately pretreated, derivatized with one of four Girard reagents, and then combined. The LC/ESI-MS/MS analysis of the combined sample provided the androgen concentrations of four serum samples in parallel. The method had practical measuring ranges, in which good precision and accuracy, as well as negligible matrix effects were verified. The speed-up capability of the developed method was evaluated through the analysis of ten batches of serum samples (total 40 samples); the method saved a 60% post-pretreatment analysis time compared to the non-derivatization method for 40 samples.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Testosterona / Espectrometría de Masas en Tándem Límite: Humans / Male Idioma: En Revista: Anal Sci Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Testosterona / Espectrometría de Masas en Tándem Límite: Humans / Male Idioma: En Revista: Anal Sci Año: 2022 Tipo del documento: Article País de afiliación: Japón